Applies To | |||
Product(s): | STAAD.Pro | ||
Version(s): | All | ||
Environment: | N/A | ||
Area: | OpenSTAAD | ||
Subarea: | Load | ||
Original Author: | Bentley Technical Support Group, Shreyanka Bhattacharjee | ||
Title: Generate Repeat Load combination with moving Load and Notional Load
Solution: A macro file is attached for this task, Moving Looad Notional Load and Repeat Load.xlsm
How to use the macro
Input:
Cell B2: Number of Primary Load cases require to be included. Here I only want to include 1 Primary Load case (Load Case1) so I have added B2 value as 1
If no Primary load cases is required to included, then B2 value will be 0
Cell B3: Primary Load Case(s) number
Cell B4: Multiplying Factor for corresponding Primary Load Case(s)
Cell B6: Starting Moving Load case number
Cell B7: Starting Moving Load case number
Cell B8: Multiplying Factor for Moving Load case
Cell B10: Load Case Factor for notional Load in X
Cell B11: Load Case Factor for notional Load in Z
Cell B13: Starting Repeat Load Case Number
Cell B14: Repeat Load case Load Type (Choose from Drop down List)
Cell B15: Path of the File along with File Name
STAAD File : communities.bentley.com/.../US_2D00_12-Moving-Load-Generation-on-a-Bridge-Deck.STD
Macro File: communities.bentley.com/.../0272.Moving-Looad-Notional-Load-and-Repeat-Load.xlsm