Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
RAM | STAAD | ADINA
  • Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki Floor Load warning in the Output File
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +Integrated Structural Modeling
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • +RAM Connection
      • +RAM Elements
      • +RAM SBeam
      • +RAM Structural System
      • -STAAD.Pro
        • +How is STAAD.Pro licensed
        • +Installation Requirements
        • +Revision History
        • -STAAD.Pro Support Solutions
          • +STAAD.Pro General [FAQ]
          • +STAAD.Pro Verification Documents
          • STAAD.Pro Safety Related Features
          • List of Programs included in different types of License for STAAD.Pro
          • STAAD Product Releases in December 2018 and Associated Licensing Changes
          • +Procedure for Downloading STAAD.Pro CE
          • +STAAD.Pro Developing The Model [FAQ]
          • +STAAD.Pro Driver Downloads [FAQ]
          • +STAAD.Pro Import/Export [FAQ]
          • +STAAD.Pro Installation/Licensing Solutions
          • +STAAD.Pro Miscellaneous Solutions
          • +STAAD.Pro Miscellaneous [FAQ]
          • +STAAD.Pro Postprocessing FAQ's
          • +STAAD.Pro Postprocessing Solutions
          • +STAAD.Pro TechNotes [TN]
          • STAAD.Pro Crashing for DELL laptop when Browsing a File Location
          • What is panel in physical modeler? How to model the panel and how to add loading on it?
          • -(+) Analytical Modeling workflow
            • +STAAD.Pro Analysis Solutions
            • +STAAD.Pro Design Solutions
            • +STAAD.Pro General Solutions
            • +STAAD.Pro Import/Export Solutions
            • -STAAD.Pro Modeling Solutions
              • **ERROR** SECTION PROPERTIES NOT ENTERED FOR MEMBER
              • A warning message while running the Eurocode Load Combination Generator appears
              • Adding PERFORM ANALYSIS and CHANGE commands in the Physical Modeler
              • Analyzing multiple disjointed structures in one model
              • Applying line Load on plates
              • Can I analyze and design a hollow core slab using STAAD.Pro?
              • Can I model retaining wall in STAAD.Pro ?
              • Cannot edit models created in the Physical modeler using the Analytical modeler
              • Changing the Orientation of Beams and Plates
              • Compression force developed in tension members
              • Connectivity issues
              • Create section by specifying Profile Points
              • Creating a custom section in the User Provided Table (UPT)
              • Defining temperature load in STAAD.Pro
              • Difference between FIXED and ENFORCED support
              • Difference between Plate, Shell and Surface Elements
              • Different member release for different load cases
              • Distributing the wheel loads to the members of the deck
              • ERROR***MATERIAL GROUP AND EXPLICIT CONSTANT SPECIFICATION CANNOT BE USED TOGETHER
              • ERROR-TOTAL JOINT/ELEMENT LIMITS EXCEEDED WHILE CREATING SURFACE
              • Eurocode Load Combination Generator creates some unrealistic load combinations
              • Fire Proofing Specification in STAAD
              • How can I define a steel section encased in concrete or a steel section with a concrete core in STAAD.Pro ?
              • How can I find out the CG of my structure
              • How can I model solid rods in STAAD.Pro
              • How do I check the integrity of my model from within the Physical Modeler workflow?
              • How to add a new section database to STAAD.Pro
              • How to add a new section in STAAD.Pro ?
              • How to change input units in STAAD.Pro CONNECT Edition ?
              • How to check modelling error in Structure
              • How to convert a "SET Z UP" model into a "SET Y UP" model
              • How to convert a LOAD COMBINATION to a REPEAT LOAD
              • How to define a cable section
              • How to determine the local Axes in created ‘InFill’ plates
              • How to find total weight of plates
              • How to generate floor loading on an inclined floor/roof ?
              • How to measure node to node distance and dimension beams in STAAD.Pro Connect Edition ?
              • How to Merge Properties
              • How to model corrugated steel plates in STAAD.Pro
              • How to scale down supports ?
              • How to specify different values of stiffness for compression and tension at the same support
              • How to use loads of the same loading type in mutually exclusive combinations when using automatic load combination
              • How to use Mass model Generator
              • How to use the SET FLOOR ANGLE TOLERANCE command to help achieve correct floor load generation.
              • How To Use the SET FLOOR LOAD TOLERANCE Command to Ensure Proper Floor Load Generation
              • How to use the tools under the Select tab to more efficiently highlight the entities in your model
              • I have defined a rigid floor diaphragm in STAAD.Pro and the axial forces in all the beams are coming out as zero
              • Identifying face numbers for Solid Elements
              • Is it possible to delete a rule created in error from "Edit Load Rules for Auto Load Combination Generation dialog" ?
              • Joint Coordinates being modified when model is moved
              • Load Path Consideration in STAAD.Pro
              • Loading options to apply the nodal/member/surface load are not active in the Physical Modeler. Why?
              • Loads are not displayed in the STAAD.Pro graphical user interface
              • Mesh generation error while adding an opening in the Parametric Models
              • Modeling a cylindrical structure with Hydrostatic Loads
              • Modeling a member with varying cross section
              • Modeling and Designing Gusset Connection in Staad.Pro
              • Modeling base plate with anchors in STAAD.Pro
              • Modeling friction support in STAAD.Pro
              • +Modeling shear walls using plates
              • Modeling slab on top of beams in STAAD.Pro
              • Modifying a Wind Load definition in the GUI
              • +Multiple support conditions within same analysis model
              • No tube sections within American Steel database
              • Not able to copy a member or node or do a translational repeat
              • Not able to see certain entities in my model
              • Partial Moment Releases
              • Seismic Analysis - Specifying seismic weights through Reference load cases
              • Setting Display units for load values in STAAD
              • Should I use a single plate or a mesh of plates for modeling slabs in STAAD.Pro
              • Some aspects to consider when analyzing mat foundations
              • STAAD.pro Create Material Macro
              • +STAAD.Pro IS:1893-2002
              • -STAAD.Pro Load Generation [FAQ]
                • **WARNING-A MOVING LOAD THAT WOULD HAVE BEEN APPLIED BEYOND THE X AND Z RANGES
                • Accounting for Accidental torsion and it’s amplification as per IBC (ASCE )
                • Applying an inclined load at a node
                • Applying wind loading on plates
                • Base shears, reactions, moments all reported as zeros for generated seismic load case
                • Code selection for Wind Load generation is grayed out
                • Defining Time history ground accelerations in orthogonal directions
                • Floor Load warning in the Output File
                • Generating Load Combinations by using Eurocode 0
                • How to apply horizontal moving loads
                • How to apply wind load ?
                • How to copy automatic load combination tables across machines
                • How to view the generated moving loads
                • Moving Loads on Plates
                • Response spectrum loading generated as per ASCE
                • Story drift check in STAAD.Pro as per ASCE7
                • Unit for Temperature Loading
                • WARNING IF THIS UBC/IBC ANALYSIS HAS TENSION/COMPRESSION
                • WARNING-NO MEMBERS IN SPECIFIED VERTICAL RANGE - in STAAD.Pro moving load generation
                • Wind load on inclined member
              • STAAD.Pro Member Specification [FAQ]
              • +STAAD.Pro Plates And Solid Elements [FAQ]
              • Using the Open Structure option
              • WARNING IN UNIFORM MEMBER LOAD. ITEM "f3" NOT PROVIDED FOR MEMBER
              • WARNING, 1 or more joints are in multiple SUPPORT commands
              • Warning, Entity # Has Already Had A Material Assigned. The Last Assigned Material Will Be Used In The Analysis
              • What are Inclined Supports and how do I use them?
              • “WARNING- TD or TB IS ZERO IN USER TABLE …”
            • +STAAD.Pro OpenSTAAD
          • +(+) Connection Design workflow
          • (+) Physical Modeling workflow
          • (+) Postprocessing workflow
          • +(+) Steel AutoDrafter worfklow
        • +STAAD.Pro CONNECT Edition - Tips & Tricks
        • +(+) STAAD.Pro Download/Installation/Security/Performance
        • +(+) STAAD.Pro Known Issues
        • (+) STAAD.Pro Licensing
        • +(+) STAAD.Pro Webinars/Videos//Events
      • +STAAD Foundation Advanced
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources
    • Simplifications to Bentley's Engineering Simulation Software Licenses

     
     Questions about this article, topic, or product? Click here. 

    Floor Load warning in the Output File

    My output file has a floor load warning . What does this mean?

    **WARNING** about Floor/OneWay Loads/Weights.  Please note that depending on the shape of the floor you may
       have to break up the FLOOR/ONEWAY LOAD into multiple commands. For details please refer to Technical     Reference Manual Section 5.32.4 Note 6."

     Answer:

    It is simply a way to remind the user to ensure that the regions on which the load is applied should comply in terms of their shape with the suggestions provided in Section 5.32.4 of the Technical Reference manual.

    The warning does not necessarily mean that there are any errors in the loads that have been generated by STAAD’s FLOOR LOAD or ONEWAY LOAD generation facilities. The user should be aware that in some instances, it is necessary to break up the floor loads and oneway loads into smaller regions.  Section 5.32.4 of the Technical Reference Manual gives a detailed explanation of these situations.

    • FAQ
    • STAAD.Pro
    • Modeling
    • SELECTsupport
    • Share
    • History
    • More
    • Cancel
    • Shany Created by Shany
    • When: Mon, Aug 26 2013 1:25 AM
    • Kris Sathia Last revision by Bentley Colleague Communities MVP Kris Sathia
    • When: Mon, Aug 26 2013 4:47 AM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies