• How to fill gap in TIN?

    I use Microstation V8i Select series 2 and GEOPAK. I've created a TIN from survey data, but the data shots in a few small areas are not close enough, there fore they didn't triangulate between them. I know I could redo the processing and set the tolerance…
  • InRoads SS2 Surface Creation Anomalies

    I have a 4 lane interstate with 4 ramps and some structures. I'm trying to perform the End Area Volume so that I can create the Mass Haul Diagram that the client wants. Towards the end of our section of the job is a large structure that I am trying to…
  • [V8i SS3 in MX] Key-in for run an Input File

    Hello, I'm a very new to MicroStation key-ins and need a hand with it. I need a key-in for auto-running last used inpud file. I can assign it to key shortcut, I also know it should start with: mxfile input but after that, it still needs "enter"…
  • InRoads V8i Interchange Modeling

    Just a quick question out to everyone. I just hope I'm not going crazy. I swear I found a video out there a few months ago showing some modeling techniques at an interchange. More specifically, it showed some vertical gore tool usage where the ramp connects…
  • .gpk file goes to "read-only" when accessed remotely

    My company uses GEOPAK V8i and has multiple office locations connected by local servers that cache project files and then connect to the main servers at our headquarters. Whenever a remote office collaborates with another office, typically headquarters…
  • Silent Install of Bentely MX v8i 08.11.09.674

    Hi, I'm trying out the Bentley MX v8i Silent Install from the "Create deployment", however, when i select the "Setup.exe" on my Network Share, everything seems to work perfectly but i then get a "Shortcut Generator" Pop up during the install of MX thus…
  • Geopak Water and Sewer: Invalid Profile?

    I am having some problems using Geopak Water and Sewer. I have one sewer line that drains east that connects to another line that drains west. Whenever I attempt to create a profile of the second line an error window pops up saying, " Invalid Profile…
  • InRoads V8i Compatibility with AutoCAD on Windows 64 bit Operating System

    Product(s): InRoads Version(s): 08.11.07+, 08.11.09+ Area: Basic Settings Question: Is InRoads V8i compatible with AutoCAD on a Windows 7 64bit? Answer: V8i SELECTseries2: CAD Platforms supported with InRoads are…
  • GéoMacao V8i 08.11.05.02 Disponible en téléchargement

    GéoMacao V8i 08.11.05.02 est disponible en téléchargement sur Bentley SELECT La liste des nouveautés relatives à cette version est disponible dans le fichier joint à ce message Nouveautés_Géomacao_XM_V8i.pdf - et notamment l'assistant Giratoire…
  • Re: Microstation V8i labellisé par l'IGN (reprojections systèmes de coordonnées)

    Bonjour, tu trouveras à l'adresse ci-dessous une série de fiches très instructives: http://www.certu.fr/fr/Information_geographique-n32/Georeferencement_et_RGF93-n795-s_thematique.html le site de l'IGN propose aussi des informations…
  • Microstation V8i labelisé par l'IGN (reprojections systèmes de coordonnées)

    C'est aujourd' *** qu'est annoncée la labelisation par l'IGN de Microstation V8i en ce qui concerne la reprojection entre Lambert 93 et les 9 projections CC. Vous pouvez donc en toute confiance convertir vos projets de Lambert II, III, ..... vers…
  • Géoréférencement

    Juste un témoignage : Pour une assez grosse affaire, je vais devoir prendre des dessins en Lambert II pour les transformer en Lambert 93. A part avec un SIG cette opération devait etre assez difficile sans un soft spécial comme MAP par exemple…
  • Re: Microstation V8i labellisé par l'IGN (reprojections systèmes de coordonnées)

    Bonjour Jean-Pierre Merci énormément pour ton explication détaillé, ça m'a un peu ouvert l'esprit et j'ai meme compris ce qu'il fallait faire !! il ne me manque plus qu'un petit eclaircissement sur ce paragraphe : Enfin il existe 9…
  • Re: info sur Geopak V 08 11 05 31

    Bonjour Laurent, Concernant la version V8i de geopak Site, tu sais qu’il y a toujours un délai entre la sortie de la version "originale" et de la version Française. Cela n’empêche pas de pouvoir utiliser la version US de Site sur un Microstation…
  • GPK Drainage - Show water and sewer crossings in profile?

    This is the first project that I have used Water/Sewer on. I am trying to get Drainage to draw the water and sewer crossings on drainage's profile views. I am able to get the sewer crossings to draw but not the water main crossings. The strange thing…
  • Re: v8i xin updates to xm

    Brian, If you make changes to the XIN file in InRoads Group V8i as you suggest, users of InRoads Group XM Edition should not have any problems opening this XIN file. InRoads Group XM Edition should just read the settings that it is familiar with…
  • Re: GPK Drainage - Show water and sewer crossings in profile?

    Dan, With many, many thanks to Michael Gilham, it was discovered that the water/sewer dgn must be referenced into slot 1 of the drainage file for the crossings to be plotted correclty on the drainage profiles. Such a simple fix but certainly…
  • Extended Geometry Descriptions

    IR V8i SS2+ How do you get the extended geometry descriptions to work with the Survey > Survey Data to Geometry command? I have a fieldbook that contains notes, so I've set that up in the extended descriptions portion of the dialog. I tried all three…
  • Instrument heights missing in PowerCivil V8i

    I have just upgraded to PowerCivil for Americas V8i V 08.11.05.37 from PowerSurvey XM (as it is no longer supported). I am in the process of creating a new dataset by importing raw survey data from a Trimble DC file and have noticed that the instrument…
  • Cross Section Labeler

    I am trying to use the GPK Corridor Modeler's Cross Section Labeler and it is giving me issues. I haven't used it in about 6 months, during which time I have made updates to Windows, MicroStation, and Geopak so it is a little tough for me to figure out…
  • Re: Location(s) for TIW and TEW files for InRoads Survey

    Please see the following discussion group posting: http://discussion.bentley.com/cgi-bin/dnewsweb.exe?cmd=article&group=bentley.inroads&item=12226&utag= Thanks, Jason Smithey
  • Re: Inroads 8.11.07.227 Application menu

    If you start from the InRoads executable and then activate Map, then it should not use an extra license. There are a couple known issues in which an extra license is used. One is when you start MicroStation, MDL Load InRoads, and then try to activate…
  • Re: measuring between 2D & 3D elements

    Depending on the version of MicroStation you are using there are ways. Older V8 version will measure the 3D slop distance if you snap to 3D points from a reference file even if you are in a 2D file. I look at this in terms thinking that all files are…
  • Re: Bentley Civil Platforms

    Neil, The LandXML Translator is located on the InRoads Group menu under File> Translators. It cannot be accessed anywhere else. The Import LDD Project tool is located in the ...\InRoads Group V8.11\bin\ldd folder and is not located in the…