<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Launching InRoads from Projectwise causes a ProjectWise Log in dialog before the DGN wil load</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/10141/launching-inroads-from-projectwise-causes-a-projectwise-log-in-dialog-before-the-dgn-wil-load</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Launching InRoads from Projectwise causes a ProjectWise Log in dialog before the DGN wil load</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/10141/launching-inroads-from-projectwise-causes-a-projectwise-log-in-dialog-before-the-dgn-wil-load</link><pubDate>Wed, 10 Dec 2014 15:09:54 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:89a7062b-d4e1-4958-a4bb-6fcf9cdfe6ef</guid><dc:creator>Kevin McDonald</dc:creator><comments>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/10141/launching-inroads-from-projectwise-causes-a-projectwise-log-in-dialog-before-the-dgn-wil-load#comments</comments><description>Current Revision posted to OpenRoads | OpenSite Wiki by Kevin McDonald on 12/10/2014 3:09:54 PM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;InRoads&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.07.615+&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Projectwise Integration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem:&amp;nbsp;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;When launching InRoads integrated with Projectwise, MicroStation launches but immediatley prompts the user to log into the datasource again.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;img width="298" height="104" alt=" " src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-52/2330.pwlogin.JPG" border="0" /&gt;&lt;/p&gt;
&lt;h1&gt;Solution:&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;There was a change introduced in&amp;nbsp;PW SS4 that required InRoads to start using the &amp;lsquo;ustation.exe&amp;rsquo; in its program association (instead of the &amp;lsquo;inroads.exe&amp;rsquo;).&amp;nbsp; This is documented in the &amp;ldquo;ProjectWise and Plotting Integration.pdf&amp;rdquo; that is delivered with the InRoads 08.11.07.615 release.&amp;nbsp; Below is a clip from this document&amp;hellip;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;code&gt;&amp;nbsp;&amp;ldquo;The program association must 1.) point to the location of the MicroStation &amp;ldquo;ustation.exe&amp;rdquo;, 2.) define the command line argument &amp;ldquo;-wsLoad_InRoads_SS2=1&amp;rdquo;, and 3.) have Enable Legacy Integration turned ON.&amp;rdquo;&lt;/code&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;Once this is set, the InRoads products are available to be loaded from the Application menu in MicroStation.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>Launching InRoads from Projectwise causes a ProjectWise Log in dialog before the DGN wil load</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/10141/launching-inroads-from-projectwise-causes-a-projectwise-log-in-dialog-before-the-dgn-wil-load/revision/1</link><pubDate>Wed, 30 Oct 2013 14:33:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:89a7062b-d4e1-4958-a4bb-6fcf9cdfe6ef</guid><dc:creator>Kevin McDonald</dc:creator><comments>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/10141/launching-inroads-from-projectwise-causes-a-projectwise-log-in-dialog-before-the-dgn-wil-load#comments</comments><description>Revision 1 posted to OpenRoads | OpenSite Wiki by Kevin McDonald on 10/30/2013 2:33:51 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;InRoads&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.07.615&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Projectwise Integration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Problem:&amp;nbsp;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;When launching InRoads integrated with Projectwise, MicroStation launches but immediatley prompts the user to log into the datasource again.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;img border="0" alt="" src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Wikis-Components-Files/00-00-00-00-52/2330.pwlogin.JPG" width="298" height="104" /&gt;&lt;/p&gt;
&lt;h1&gt;Solution:&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;There was a change introduced in&amp;nbsp;PW SS4 that required InRoads to start using the &amp;lsquo;ustation.exe&amp;rsquo; in its program association (instead of the &amp;lsquo;inroads.exe&amp;rsquo;).&amp;nbsp; This is documented in the &amp;ldquo;ProjectWise and Plotting Integration.pdf&amp;rdquo; that is delivered with the InRoads 08.11.07.615 release.&amp;nbsp; Below is a clip from this document&amp;hellip;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;code&gt;&amp;nbsp;&amp;ldquo;The program association must 1.) point to the location of the MicroStation &amp;ldquo;ustation.exe&amp;rdquo;, 2.) define the command line argument &amp;ldquo;-wsLoad_InRoads_SS2=1&amp;rdquo;, and 3.) have Enable Legacy Integration turned ON.&amp;rdquo;&lt;/code&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;Once this is set, the InRoads products are available to be loaded from the Application menu in MicroStation.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See also:&lt;/h1&gt;
&lt;p&gt;&lt;a href="/products/road___site_design/w/road_and_site_design__wiki/8674.aspx"&gt;Create/Edit Alignment by Cogo Points - Point Name Not Found&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item></channel></rss>