In Data Acquisition, how do I set the linear feature stroking tolerance for surface creation?
The default linear element stroking values for metric are 20.0 for Linear and 0.03 for Curve.
The default linear element stroking values for imperial are 50.0 for Linear and 0.1 for Curve.
User defined stroking tolerances can be enabled using these two configuration variables.
· DA_STROKE_TOLERANCE_LINEAR= <value>
· DA_STROKE_TOLERANCE_CURVE= <value>