Problem: You have existing MXTIP files using the existing profile dll to include drainage annotation. You wish to take advantage of the improved, dedicated, DrainageProfile.dll
a. Make sure that DrainageProfile.dll is in the XX_sys folder and is registered on the system.
b. Copy the existing customised profile mxtips file to a new file name.
c. Edit the new file in a text editor. You will notice the structure is in a standard file path format eg :
Profile\DrainageGroup\Boxes2Profile\DrainageGroup\Boxes\DepthToInvertBox2
Each line has a following value line, so when you are asked to delete lines, delete both the path line and the value line.
d. Replace the top four lines with these:
DrainageGroupExe=DrainageProfile.InterfaceDrainageGroup1
e. Delete any lines that do not contain DrainageGroup or ServiceGroup. These drainage entries are at the bottom of the file.
f. Do a global substitution changing "Profile\DrainageGroup" to "DrainageGroup".
g. Save the file.
h. Load it into the GA panel. (geometric annotation panel)
i. Modify the top level properties for scale, distance to top and bottom of profile etc.
If you are in any doubt or have problems altering your files then contact the support desk. (+44 1403 217749)
Product TechNotes and FAQs
MX TechNotes And FAQs
Bentley Technical Support KnowledgeBase
Bentley LEARN Server