Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenRoads | OpenSite
  • Product Communities
OpenRoads | OpenSite
OpenRoads | OpenSite Wiki Troubleshooting the Bentley-Civil Workspace
    • Sign In
    • -Road and Site Design - Wikis
      • +OpenRoads Designer
      • +OpenRoads ConceptStation
      • +OpenRail Designer
      • +OpenSite Designer
      • +OpenRoads Navigator Mobile App
      • -SS10/SS4/SS3 OpenRoads
        • Platform compatibility
        • +SS4/SS3 Subsurface Utilities Video Clips, TechNotes & FAQs
        • +3D Geometry (SS4)
        • +Analysis & Reporting (SS4)
        • -Basic Settings (SS4/SS10)
          • "No content available to display" in Item Browser
          • .NET Errors while using OpenRoads
          • 3D Graphics Display Issues
          • AASHTO Design Standards 2011.DGNLib for International Foot
          • Are the Overhead Line Tools available in InRoads SS3?
          • Attaching SHP file and graphics are scaled by foot to meter conversion (3.28)
          • Automatically Check In InRoads Files on Exit
          • Bentley Civil V8i SELECTseries 4: Platform Requirement and Product Add-On Versions
          • Best Practices Document
          • Can GEOPAK SS2 and SS3 be installed on the same machine?
          • Can GEOPAK SS2/SS3 be installed on the same machine as GEOPAK SS4?
          • Can I Disable Unlicensed Products that are Downloaded with InRoads Suite?
          • Can I Launch MicroStation and then Load InRoads SS3/SS4 from the Applications Menu?
          • Can InRoads SS2 and SS3 be installed on the same machine?
          • Can InRoads SS2 and SS4 be installed on the same machine?
          • Can Multiple Civil Products be Installed on the Same Machine?
          • Change Type of Feature Definition
          • contentmngmx deletemxdata *
          • Context Tool Box: Turn on/Turn Off
          • Create Element Templates From Levels in DGNLIB
          • Creating Design Standards
          • Customizing OpenRoads Tools and Commands
          • Default Function Key Assignments in OpenRoads
          • Define Feature Definition DGNLIBs in Workspace (SS4)
          • Display issues while working in a 3-D file
          • Display Problems - Stray Lines or No Lines in DGN
          • Does InRoads/MX/GEOPAK SS4 run on Windows 10?
          • Does the Create ICM command use the CIVIL_iMODEL_INCLUDE_ICM configuration variable?
          • Drag handles missing
          • Dual Install of GEOPAK SS2 and SS3
          • Enable/Disable Civil Products From Within MicroStation
          • Error Message Installing SS3/SS4 Civil Product: "A supported version of MicroStation must be installed..."
          • Error Message: "Another version is already installed..."
          • Error Message: Obsolete Civil Data Found
          • Export Settings
          • Feature Definition Check Boxes
          • Getting Windows Installer Preparing to install... message when accessing various InRoads commands
          • How can I remove the civil data from a DGN?
          • How do I access Help in Openroads SS4 (InRoads/GEOPAK/MX)?
          • How do I close or minimize the InRoads Explorer?
          • How Do I remove the Civil Feature from an Element
          • How to change the Civil AccuDraw X, Y operation to Northing, Easting
          • How to Export OpenRoads design to MXRoad model
          • How to fix error 2753
          • How to Remove the Lock in the Heads-up Display
          • InRoads SS3 - Product Add-ins are no longer available.
          • Installing MicroStation V08.11.09.832 on a machine that has a previous version of MicroStation installed
          • Invalid MicroStation Format Error
          • Load MicroStation without InRoads SS3 using a license?
          • No Civil Tools under the Task menu when launching InRoads
          • No Feature Definition
          • Open Civil Message Center
          • OpenRoads Frequently Asked Questions
          • OpenRoads Glossary of Terms
          • OpenRoads on AutoCAD?
          • OpenRoads Product Overview
          • OpenRoads SS4 Special Interest Group (SIG) FAQs
          • OpenRoads Terminology
          • Program will not open after update to latest version - SubsurfaceUtilitiesSamples.cfg error
          • Project Explorer Civil Tabs are Missing
          • Project Managed Workspace error starting InRoads or GEOPAK in ProjectWise CONNECT V10.00.02.265
          • Projectwise: GUIDs are Displayed Instead of Folder and File Names
          • Remove Design Standards from Element
          • Replaced missing TrueType font...
          • Screen Blacks out while working in 3d
          • Set Default XIN File in OpenRoads
          • Setting Up Design Standards in OpenRoads
          • Setting up TxDOT Workspace for PowerGEOPAK
          • Silent Install of InRoads SS3 Preventing Install of Descartes and/or Subsurface Utility Engineering
          • Silent Install of PowerCivil for <Country>
          • Site Modeler in InRoads SS3
          • SS10 Configuration folder directories
          • Storm & Sanitary and RailTrack are not available in SS3
          • Survey Foot Units in SS4?
          • Technology Preview Learning Path
          • Terrain Model Feature Type in Feature Definitions
          • Terrain models from SS3 to SS2
          • Troubleshooting the Bentley-Civil Workspace
          • Troubleshooting Tips for .NET Framework Errors
          • Unable to Access Survey, Civil Standards or Civil Model in Project Explorer
          • Unable to define some settings in Project Options in SS3
          • Unable to Delete MicroStation Level
          • Unable to Detach Reference File in MicroStation
          • Unable to set Unit Station Length in Project Options
          • Unhandled Exception Error
          • Upgrade License when Upgrading InRoads?
          • Upgrading DGNLIB, Seed Files, and Civil Cells to SS4
          • Using Customized feature definitions
          • Version 08.11.09.722 - MicroStation (SELECTseries 3) 08.11.09.608 prerequisite installation
          • Video: Adding EC Attributes
          • Video: Adding New Styles to Native and Updating Feature Definitions
          • Video: Best Practices for Project File Organization in OpenRoads
          • Video: Create Template - Surface Feature Definitions and Element Templates
          • Video: Creating a 3D Linestyle for use in Corridor Modeling
          • Video: Creating a Custom Toolbar
          • Video: Exporting ICM
          • Video: Feature Definitions - Linear, Point, Surface
          • Video: How to Import Feature Definitions (GEOPAK)
          • Video: How to Import Feature Definitions (InRoads)
          • Video: Introduction to Features and Feature Definitions
          • Video: Migrate Component Styles from SS2 to OpenRoads
          • Video: Quick Start Topics
          • Video: Quick tip on rotating the compass in Civil Accudraw
          • Video: Rename DGN Files and Preserve Civil Relationships
          • Video: Simple Example of Managing Reference File Attachments
          • Video: Transfer Information from One Workspace to Another
          • Video: Updating civil elements after symbology changes in native XIN/DDB
          • Video: Updating Feature Definitions from a Revised DGNLIB
          • What msconfig variable defines the location of the civil preferences and commands
          • Where are the Cross Section and Modeler Commands in SS3/SS4/SS10?
          • Where are the OpenRoads commands?
          • Where is a list of OpenRoads Configuration Variables?
          • Where is Help in SS4?
          • Where to Download MicroStation 08.11.09.714?
          • Where to Download MicroStation 08.11.09.832
          • Which version of InRoads/GEOPAK/MX will run on MicroStation CONNECT?
        • +Civil Cells (SS4)
        • +Corridor Modeling & Cross Sections (SS4)
        • geopakcom.exe - Entry Point Not Found - PowerGeopak Install Error in Windows 10
        • +General Geometry (SS4)
        • +Horizontal Geometry (SS4)
        • +Rail Track (SS4)
        • ReadMe - What's new and revised in SS4 MR3 - Version 08.11.09.903+
        • +Survey (SS4)
        • +Terrain Model (SS4)
        • +Training for OpenRoads commands in InRoads/GEOPAK/MX SS4
        • +Vertical Geometry (SS4)
        • Visual Basic Run-time error '-2147467259 (80004005)' when loading GEOPAK through FDOT workspace
        • Why warning display Create an Unlinked Terrain Model
        • How to launch InRoads/GEOPAK SS10 from ProjectWise CONNECT
        • Print and Print to File Button Not Working
        • Problems Running SS4 VBA in SS10
        • Wiki: How to create a turnout library for specific project as the options available to create new turnout library is disabled ?
      • +GEOPAK Native
      • +InRoads Native
      • +MX Native
      • +OpenRoads SignCAD

     
     Questions about this article, topic, or product? Click here. 

    Troubleshooting the Bentley-Civil Workspace

    Product(s): InRoads, MX, GEOPAK
    Version(s): 08.11.09+
    Area:  Workspace

     

    Question:

    What do I do if I do not see the Bentley-Civil-Imperial or Bentley-Civil-Metric project workspaces in the "examples" user?

    Answer:

    The article below describes steps to follow to troubleshoot the installation and use of the Bentley-Civil workspaces:


    Troubleshooting the Bentley-Civil Workspace

    The Bentley-Civil workspace is installed as part of the software installation. When properly installed and configured the workspace is available from the startup screen in the software by selecting the User named examples and the Project named Bentley-Civil-Imperial or Bentley-Civil-Metric.

    Workspace Not Installed

    If the examples user or the Bentley-Civil projects are not available to select when you start the software, check the following.

    1. Browse to the folder DRIVE:\\ProgramData\Bentley\{PRODUCT NAME}\WorkSpace\Projects\Examples\ where {PRODUCT NAME} is replaced with your installed product name and version such as (\ProgramData\Bentley\PowerInRoads V8i (SELECTseries 4)\WorkSpace\Projects\Examples\).

       NOTE: If you are using Windows XP or older software the folder will be DRIVE:\\Documents and Settings\All Users\Application Data\Bentley\{PRODUCT NAME}\WorkSpace\Projects\Examples\.

    2. Verify that the Bentley-Civil-Imperial and Bentley-Civil-Metric folders exist and that they contain sub folders and files.

    3. If these folders do not exist…

      1. Enter the windows Control Panel and select the Programs and Features.

      2. Right click on your installed Bentley Civil application and select Repair. You may need administrator rights to complete this action.

    4. If the folders do exist follow the ‘Workspace Installed but not Found’ steps below for the appropriate application to setup a new configuration file for the Bentley-Civil workspace.

     

    Workspace Installed but not Found - InRoads, Power InRoads, GEOPAK, Power GEOPAK, PowerCivil, or Power Rail Track Software

    1. Start the InRoads, GEOPAK, PowerCivil or Rail Track software.

    2. Create a new User Configuration.

      1. On the File Open window, click the drop-down menu for the User and select New.

      2. Key in Bentley-Civil Workspace in the Name field and click OK.

      3. On the Create User Configuration File dialog, define the Project location by clicking the Select button and browsing to and selecting the \ProgramData\Bentley\{PRODUCT NAME}\WorkSpace\Projects\Examples\Bentley-Civil-Imperial.pcf file.
        NOTE: If you are using Windows XP or older software the folder will be DRIVE:\\Documents and Settings\All Users\Application Data\Bentley\{PRODUCT NAME}\WorkSpace\Projects\Examples\.

      4. Click OK to create the new user configuration file.

    3. On the File Open window, set the User to Bentley-Civil Workspace.

    4. You will now be able to select Bentley-Civil-Imperial or Bentley-Civil-Metric from the Project pick list.

    Workspace Installed but not Found - MX ROAD Software

    1. Browse to the Bentley MXROAD installation location DRIVE:\\ProgramData\Bentley\ MX V8i (SELECT Series 4)\Workspace\Users\.
       NOTE: If you are using Windows XP or older software the folder will be DRIVE:\\Documents and Settings\All Users\Application Data\Bentley\MX V8i (SELECT Series 4)\Workspace\Users\.

    2. Create a new text file named Bentley-Civil Workspace.ucf.

    3. Define the _USTN_PROJECT variable in this file as shown below. NOTE: The file path needs to match where your software is installed and will be the same as the path used in step 1.

    4. Save the new Bentley-Civil Workspace.ucf.

    5. Start the MX ROAD software.

    6. On the MX Project Start Up dialog, set the User to Bentley-Civil Workspace.

    7. You will now be able to select Bentley-Civil-Imperial or Bentley-Civil-Metric from the Project pick list.

    • Share
    • History
    • More
    • Cancel
    • Kevin McDonald Created by Bentley Colleague Kevin McDonald
    • When: Mon, Aug 31 2015 11:16 AM
    • Kevin McDonald Last revision by Bentley Colleague Kevin McDonald
    • When: Mon, Aug 31 2015 12:06 PM
    • Revisions: 8
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies