<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Link Conduits to Center of Inlet</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/24034/link-conduits-to-center-of-inlet</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Link Conduits to Center of Inlet</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/24034/link-conduits-to-center-of-inlet</link><pubDate>Thu, 25 Feb 2016 12:24:55 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f02640c9-70e1-4042-b943-6c4af23a8b18</guid><dc:creator>Robert Garrett</dc:creator><comments>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/24034/link-conduits-to-center-of-inlet#comments</comments><description>Current Revision posted to OpenRoads | OpenSite Wiki by Robert Garrett on 2/25/2016 12:24:55 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:680px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;InRoads, MX, GEOPAK&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.845+&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Subsurface Utilities&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:150%;"&gt;&lt;span style="text-decoration:underline;"&gt;Question:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Can conduits link to the center of the inlet instead of the walls of the inlets?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="font-size:150%;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Yes, you will need to omit the connection regions when defining the cells. &amp;nbsp;The connection regions are defined in the bottom cell and can be surface elements, shapes or solids defined as construction class and line style 6&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Questions:&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;OK, but I ave configured my cells to connect at the face of the vault, which I want to happen. &amp;nbsp;The problem is that they always connect to the center. &amp;nbsp;What&amp;#39;s wrong?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Answer:&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Of course, the first action is to double check your feature definition library and cell libraries to confirm that the connection regions are properly configured and that the feature definitions are loading the cells that you think they are using. &amp;nbsp;&lt;/p&gt;
&lt;p&gt;But, then check you Accusnap settings. &amp;nbsp;Make sure that the check box to &amp;quot;Identify Elements automatically&amp;quot; is ON .&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" height="60" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>Link Conduits to Center of Inlet</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/24034/link-conduits-to-center-of-inlet/revision/2</link><pubDate>Tue, 15 Sep 2015 18:47:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f02640c9-70e1-4042-b943-6c4af23a8b18</guid><dc:creator>Jacquelyn Pettus</dc:creator><comments>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/24034/link-conduits-to-center-of-inlet#comments</comments><description>Revision 2 posted to OpenRoads | OpenSite Wiki by Jacquelyn Pettus on 9/15/2015 6:47:05 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:680px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;InRoads, MX, GEOPAK&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.845+&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Subsurface Utilities&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:150%;"&gt;&lt;span style="text-decoration:underline;"&gt;Question:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Can conduits link to the center of the inlet instead of the walls of the inlets?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="font-size:150%;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Yes, you will need to omit the connection regions when defining the cells.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" height="60" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>Link Conduits to Center of Inlet</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/24034/link-conduits-to-center-of-inlet/revision/1</link><pubDate>Tue, 15 Sep 2015 18:46:38 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f02640c9-70e1-4042-b943-6c4af23a8b18</guid><dc:creator>Jacquelyn Pettus</dc:creator><comments>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/24034/link-conduits-to-center-of-inlet#comments</comments><description>Revision 1 posted to OpenRoads | OpenSite Wiki by Jacquelyn Pettus on 9/15/2015 6:46:38 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:680px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;InRoads, MX, GEOPAK&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.845+&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Subsurface Utilities&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:150%;"&gt;&lt;span style="text-decoration:underline;"&gt;Question:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Can conduits link to the center of the inlet instead of the walls of the inlets&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="font-size:150%;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Yes, you will need to omit the connection regions when defining the cells.&lt;/p&gt;