<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>SignCAD Integration with GEOPAK</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/34760/signcad-integration-with-geopak</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>SignCAD Integration with GEOPAK</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/34760/signcad-integration-with-geopak</link><pubDate>Thu, 20 Apr 2017 13:53:33 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:692f80f1-e07d-41b6-a6a6-26e942002240</guid><dc:creator>Sanders Thomas</dc:creator><comments>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/34760/signcad-integration-with-geopak#comments</comments><description>Current Revision posted to OpenRoads | OpenSite Wiki by Sanders Thomas on 4/20/2017 1:53:33 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:680px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;InRoads, MX, GEOPAK&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09+&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;General&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sanders Thomas, Bentley Technical Support Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:150%;"&gt;&lt;span style="text-decoration:underline;"&gt;Question:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;How can I run SignCAD in GEOPAK? GEOPAK crashes when trying to open a design file after SignCAD has been installed.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="font-size:150%;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;In MicroStation, pick Utilities&amp;gt;MDL Applications. In the MDL dialog box, press the Browse button. Browse to your C:\SignCAD\Ustn folder and select the SignCADXM and press Open. Pick SIGNCADXM from under the Available Applications and press the Load button. SIGNCADXM should now display under Loaded Applications.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/8420.1.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/8420.1.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;You will also want to make sure that the SignCAD .rsc files are listed in the Expansion under Symbology as shown below:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/1300.2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/1300.2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Once the SignCAD MDL is loaded, you will see an Applications menu with SignCAD under it.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/4111.3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/4111.3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;You should also be able to select a sign in SignCAD (hold down key and window select your sign), copy it (Edit&amp;gt;Copy) and paste it into MicroStation (Paste&amp;gt;SignCAD Sign To Design File).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/3036.4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/3036.4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the SignCAD MDL doesn&amp;rsquo;t stay loaded for you, then in MicroStation, go to Workspace&amp;gt;Configuration. Make sure the SIGNCADXM displays under the Expansion as shown below:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/0804.5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/0804.5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If you don&amp;rsquo;t see the path for the SIGNCADXM, you will need to add it. Pick the Edit button and add the path C:\SignCAD\ustn\SignCADXM.ma in the New Value section so it appears in the Expansion as shown below:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/5277.6.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/5277.6.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Press OK to both dialog boxes and then press Yes to the dialog box shown below:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/2541.7.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/2541.7.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;You may need to exit MicroStation and then open it again for the changes to work.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;The SignCAD config files for the different versions of MicroStation are located in the C:\SignCAD\ustn folder as shown below:&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/a.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/a.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;MicroStation SELECTseries 3 &amp;amp; 4 use the SignCADXM.cfg file.&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Copy the correct .cfg file for the version of MicroStation you are using into the C:\Program Files (x86)\Bentley\MicroStation V8i (SELECTseries)\MicroStation\config\appl folder.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;If&amp;nbsp;ProjectWise or GEOPAK are installed, then the config file needs to be in the folder where those programs expect to find it. Those programs don&amp;#39;t look in the default folder for MicroStation. Below is an example path for GEOPAK:&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/5684.8.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/5684.8.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>SignCAD integration with GEOPAK</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/34760/signcad-integration-with-geopak/revision/2</link><pubDate>Thu, 20 Apr 2017 13:52:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:692f80f1-e07d-41b6-a6a6-26e942002240</guid><dc:creator>Sanders Thomas</dc:creator><comments>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/34760/signcad-integration-with-geopak#comments</comments><description>Revision 2 posted to OpenRoads | OpenSite Wiki by Sanders Thomas on 4/20/2017 1:52:59 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:680px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;InRoads, MX, GEOPAK&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09+&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;General&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sanders Thomas, Bentley Technical Support Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:150%;"&gt;&lt;span style="text-decoration:underline;"&gt;Question:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;How can I run SignCAD in GEOPAK? GEOPAK crashes when trying to open a design file after SignCAD has been installed.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="font-size:150%;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;In MicroStation, pick Utilities&amp;gt;MDL Applications. In the MDL dialog box, press the Browse button. Browse to your C:\SignCAD\Ustn folder and select the SignCADXM and press Open. Pick SIGNCADXM from under the Available Applications and press the Load button. SIGNCADXM should now display under Loaded Applications.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/8420.1.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/8420.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;You will also want to make sure that the SignCAD .rsc files are listed in the Expansion under Symbology as shown below:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/1300.2.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/1300.2.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Once the SignCAD MDL is loaded, you will see an Applications menu with SignCAD under it.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/4111.3.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/4111.3.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;You should also be able to select a sign in SignCAD (hold down key and window select your sign), copy it (Edit&amp;gt;Copy) and paste it into MicroStation (Paste&amp;gt;SignCAD Sign To Design File).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/3036.4.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/3036.4.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the SignCAD MDL doesn&amp;rsquo;t stay loaded for you, then in MicroStation, go to Workspace&amp;gt;Configuration. Make sure the SIGNCADXM displays under the Expansion as shown below:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/0804.5.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/0804.5.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If you don&amp;rsquo;t see the path for the SIGNCADXM, you will need to add it. Pick the Edit button and add the path C:\SignCAD\ustn\SignCADXM.ma in the New Value section so it appears in the Expansion as shown below:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/5277.6.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/5277.6.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Press OK to both dialog boxes and then press Yes to the dialog box shown below:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/2541.7.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/2541.7.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;You may need to exit MicroStation and then open it again for the changes to work.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;The SignCAD config files for the different versions of MicroStation are located in the C:\SignCAD\ustn folder as shown below:&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/a.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/a.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;MicroStation SELECTseries 3 &amp;amp; 4 use the SignCADXM.cfg file.&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Copy the correct .cfg file for the version of MicroStation you are using into the C:\Program Files (x86)\Bentley\MicroStation V8i (SELECTseries)\MicroStation\config\appl folder.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;If&amp;nbsp;ProjectWise or GEOPAK are installed, then the config file needs to be in the folder where those programs expect to find it. Those programs don&amp;#39;t look in the default folder for MicroStation. Below is an example path for GEOPAK:&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-52/5684.8.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-52/5684.8.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>SignCAD integration with GEOPAK</title><link>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/34760/signcad-integration-with-geopak/revision/1</link><pubDate>Thu, 20 Apr 2017 13:44:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:692f80f1-e07d-41b6-a6a6-26e942002240</guid><dc:creator>Sanders Thomas</dc:creator><comments>https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/34760/signcad-integration-with-geopak#comments</comments><description>Revision 1 posted to OpenRoads | OpenSite Wiki by Sanders Thomas on 4/20/2017 1:44:39 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:680px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;InRoads, MX, GEOPAK&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09+&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;General&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sanders Thomas, Bentley Technical Support Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:150%;"&gt;&lt;span style="text-decoration:underline;"&gt;Question:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;How can I run SignCAD in GEOPAK? GEOPAK crashes when trying to open a design file after SignCAD has been installed.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="text-decoration:underline;"&gt;&lt;span style="font-size:150%;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;In MicroStation, pick Utilities&amp;gt;MDL Applications. In the MDL dialog box, press the Browse button. Browse to your C:\SignCAD\Ustn folder and select the SignCADXM and press Open. Pick SIGNCADXM from under the Available Applications and press the Load button. SIGNCADXM should now display under Loaded Applications.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;You will also want to make sure that the SignCAD .rsc files are listed in the Expansion under Symbology as shown below:&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Once the SignCAD MDL is loaded, you will see an Applications menu with SignCAD under it.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;You should also be able to select a sign in SignCAD (hold down  key and window select your sign), copy it (Edit&amp;gt;Copy) and paste it into MicroStation (Paste&amp;gt;SignCAD Sign To Design File).&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " /&gt;&lt;/p&gt;
&lt;p&gt; If the SignCAD MDL doesn&amp;rsquo;t stay loaded for you, then in MicroStation, go to Workspace&amp;gt;Configuration. Make sure the SIGNCADXM displays under the Expansion as shown below:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " /&gt;&lt;/p&gt;
&lt;p&gt; If you don&amp;rsquo;t see the path for the SIGNCADXM, you will need to add it. Pick the Edit button and add the path C:\SignCAD\ustn\SignCADXM.ma in the New Value section so it appears in the Expansion as shown below:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " /&gt;&lt;/p&gt;
&lt;p&gt; Press OK to both dialog boxes and then press Yes to the dialog box shown below:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " /&gt;&lt;/p&gt;
&lt;p&gt; You may need to exit MicroStation and then open it again for the changes to work. &lt;/p&gt;
&lt;p&gt;The SignCAD config files for the different versions of MicroStation are located in the C:\SignCAD\ustn folder as shown below:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " /&gt;&lt;/p&gt;
&lt;p&gt; MicroStation SELECTseries 3 &amp;amp; 4 use the SignCADXM.cfg file. &lt;/p&gt;
&lt;p&gt;Copy the correct .cfg file for the version of MicroStation you are using into the C:\Program Files (x86)\Bentley\MicroStation V8i (SELECTseries)\MicroStation\config\appl folder. &lt;/p&gt;
&lt;p&gt;If PROJECTWISE or GEOPAK are installed, then the config file needs to be in the folder where those programs expect to find it. Those programs don&amp;#39;t look in the default folder for MicroStation. Below is an example path for GEOPAK:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item></channel></rss>