Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenRoads | OpenSite
  • Product Communities
OpenRoads | OpenSite
OpenRoads | OpenSite Wiki Epaisseurs de trait
    • Sign In
    • -Road and Site Design - Wikis
      • +OpenRoads Designer
      • +OpenRoads ConceptStation
      • +OpenRail Designer
      • +OpenSite Designer
      • +OpenRoads Navigator Mobile App
      • +SS10/SS4/SS3 OpenRoads
      • +GEOPAK Native
      • +InRoads Native
      • -MX Native
        • +Analysis
        • +Arenium
        • Capture Google Earth image not working in MX SS4
        • Cycle MX Status Tooltips between Coincident strings.
        • +Data Import & Export
        • +Design Options
        • +Display / Draw
        • +Drainage Design
        • +Error Messages
        • Graphical Filters for Terrain Models
        • How to Change Color Table in MX v8i Select Series 3
        • +Installation & Configuration
        • Maximum limit for chainage
        • +Modify
        • +MX and AutoCAD
        • +MX Tools / Add-Ins
        • MX v8i Showing Trial/Demo Message after Product Activation
        • MX v8i Status Tooltips
        • -MX-Trucs et Astuces [TN]
          • +Annotation
          • +Import et Export
          • +Impression
          • +Installation et Configuration
          • -Principes de fonctionnement
            • Epaisseur de ligne
            • Epaisseurs de trait
            • Le lissage dans MX
          • +Références
          • +Visualisation
        • Pavement and Subgrade Design
        • +Project
        • +Project Explorer Settings
        • +Report
        • +Visualise
      • +OpenRoads SignCAD

     
     Questions about this article, topic, or product? Click here. 

    Epaisseurs de trait

    Comment sont gérées les épaisseurs de traits dans MX autonome (versions XM 08.09.xx.xx et supérieures) ?

    • Microstation utilise des numéros d'épaisseur de 0 (le plus fin) à 31 (le plus épais).
    • Les Jeux de styles MX utilise directement ces épaisseurs.
    • Les commandes MX en particulier 805 permettent de donner une épaisseur de trait mais ce n'est pas directement le numéro d'épaisseur Microstation. Un fichier fait la correspondance entre l'épaisseur MX et l'épaisseur Microstation:

    Documents and Settings/All users/Application Data/Bentley/MX/mfm/mx_line_widths.dat

    Lors de l'impression les numéros d'épaisseur sont convertis en épaisseurs d'impression. L'épaisseur peut être réglée pour chaque traceur. Cela sera souvent fait, comme pour des affectations de couleurs, à travers la configuration du pilote d'impression (<imprimante>.pltcfg).

    Epaisseur MX ------ (mx_line_width.dat) -----> Numéro d'épaisseur ------- (pltcfg) -------------> Epaisseur tracée

    Exemples de Fichier mx_line_widths .dat

    Le fichier STANDARD est ainsi:

    Colonne 1= Numéro d'épaisseur Microstation
    Colonne 2= épaisseur MX

    Le numéro d'épaisseur correspondant à l'épaisseur la plus proche de celle donnée dans MX est utilisée.

    *
    * MOSS line width mapping file
    *
    * First column is the Microstation line weight number
    * Second column is the MOSS line width
    *
    * The nearest line width in column 2 in this table to the given MOSS line width 
    * will result in the corresponding Microstation line weight number being used 
    * for that entity.
    *
    * Maximum number of rows 32
    *

    0            0.18
    1            0.25
    2            0.35
    3            0.50
    4            0.70
    5            1.00
    6            1.40
    7            2.00
    8            2.50
    9            3.00
    10           3.50
    11           4.00
    12           4.50
    13           5.00
    14           5.50
    15           6.00
    16           6.50
    17           7.00
    18           7.00
    19           7.00
    20           7.00
    21           7.00
    22           7.00
    23           7.00
    24           7.00
    25           7.00
    26           7.00
    27           7.00
    28           7.00
    29           7.00
    30           7.00
    31           7.00

    Fichier reprenant les épaisseurs de tracé standard de Microstation:

    0            0.169
    1            0.375
    2            0.500
    3            0.625
    4            0.750
    5            0.875
    6            1
    7            1.125
    8            1.250
    9            1.375
    10           1.500
    11           1.625
    12           1.750
    13           1.875
    14           2
    15           2.125
    16           2.250
    17           2.375
    18           2.500
    19           2.625
    20           2.750
    21           2.875
    22           3
    23           3.125
    24           3.250
    25           3.375
    26           3.500
    27           3.625
    28           3.750
    29           3.875
    30           4
    31           4.125

    Fichier permettant d'utiliser directement le numéro d'épaisseur Microstation dans les commandes MX:

    0            0
    1            1
    2            2
    3            3
    4            4
    5            5
    6            6
    7            7
    8            8
    9            9
    10           10
    11           11
    12           12
    13           13
    14           14
    15           15
    16           16
    17           17
    18           18
    19           19
    20           20
    21           21
    22           22
    23           23
    24           24
    25           25
    26           26
    27           27
    28           28
    29           29
    30           30
    31           31

     

    Rermarques:

    • la commande 805 n'acceptant pas la valeur 0, vous donnerez par exemple une épaisseur de 0.1 afin que l'épaisseur 0 soit utilisée.
    • attention: un tel fichier peut transformer vos dessins si vous utilisez de nombreuses procédures et macros. Elles nécessiteront d'être adaptées. Dans ce cas elles seront dédiées à MX autonome et ne pourront pas servir dans MX AutoCAD.
    • Share
    • History
    • More
    • Cancel
    • jpln Created by Bentley Colleague jpln
    • When: Mon, Jan 14 2013 5:20 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies