Get Load and Factor for load combination case


  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: STAAD.Pro Technotes
 Subarea: OpenSTAAD
 Original Author:Surojit Ghosh
  

 

 

 

 

 

 

 

 

The following OpenSTAAD function extracts the load case number (Primary and combination load case) and corresponding combination factors for a combination load case.

Load.GetLoadAndFactorForCombination varLoadCombNo, varLoadNos, varFactors

Where:

varLoadCombNo

A long variable which stores the load combination number.

varLoadNos

A long array which stores the load case numbers present in the load combination.

varFactors

A double array which stores the combination factor corresponding to each load case present in the load combination.

VB Example

Dim varLoadCombNo As Long

Dim varLoadNos As Long

Dim varFactors As Double

objOpenSTAAD.Load.GetLoadAndFactorForCombination varLoadCombNo, varLoadNos, varFactors