Error: "The file type is not supported - [12]" when attaching Image using Raster Manager in OpenUtilities Substation
Satish Saptasagar
Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.14.XX.XX Environment: NA Area: Power Platform Support Subarea: NA Background: The user get the below error message when…
4 months ago
OpenUtilities
OpenUtilities Wiki
How to add Custom Fonts in Promis.e CONNECT
Satish Saptasagar
Product(s): Promis.e CONNECT Edition Version(s): 10.00.XX.XX to 10.10.XX.XX Environment: NA Area: Power Platform Subarea: NA Background: Users may need to use Custom Font Style for text in…
over 1 year ago
OpenUtilities
OpenUtilities Wiki
When Promis.e page is Export to DWG/DXF the some of the symbol graphics are not visible
Satish Saptasagar
Product(s): Promis.e CONNECT Edition Version(s): 10.03.XX.XX to 10.09.XX.XX Environment: NA Area: Power Platform Support Subarea: NA Background: The user sometimes may come across issues…
over 1 year ago
OpenUtilities
OpenUtilities Wiki
How to enable ESC key to exit current active command - OpenUtilities Substation
Satish Saptasagar
Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.00.XX.XX to 10.11.XX.XX Environment: NA Area: Power Platform Support Subarea: NA Background: Users might want to use the…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to enable ESC key to exit current active command - Promis.e CONNECT
Satish Saptasagar
Product(s): Promis.e CONNECT Edition Version(s): 10.00.XX.XX to 10.09.XX.XX Environment: NA Area: Power Platform Support Subarea: NA Background: Users might want to use the ESC button to…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to Merge a Reference drawing into Promis.e Connect
Satish Saptasagar
Product(s): Promis.e CONNECT Edition Version(s): 10.09.XX.XX Environment: NA Area: Power Platform Support Subarea: NA Background: In the latest version of Promis.e for a Reference the Device…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to Merge a Reference drawing into OpenUtilities Substation
Satish Saptasagar
Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.11.XX.XX Environment: NA Area: Power Platform Support Subarea: NA Background: In the latest version of OpenUtilities Substation…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to make command dialogs to pop up on particular screen for machine with Multiple Screens
Satish Saptasagar
Product(s): Promis.e CONNECT Edition Version(s): 10.00.XX.XX to 10.08.XX.XX Environment: NA Area: Power Platform Support Subarea: NA Background: When working on Promis.e CONNECT on a machine…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to Batch Convert Promis.e DGN drawings to DWG
Satish Saptasagar
Product(s): Promis.e CONNECT Edition Version(s): 10.00.XX.XX to 10.08.XX.XX Environment: NA Area: Power Platform Support Subarea: NA Background: How to convert and save Multiple Promis.e…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to Restrict users from Creating and or Selecting WorkSpace and WorkSet in Promis.e CONNECT
Satish Saptasagar
Product(s): Promis.e CONNECT Edition Version(s): 10.00.XX.XX to 10.07.XX.XX Environment: NA Area: Power Platform Support Subarea: NA Background: By default, the user can Create WorkSpace…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
Descartes License Check-out after launching OpenUtilities Substation
Satish Saptasagar
Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.00.XX.XX to 10.09.XX.XX Environment: NA Area: Power Platform Support Subarea: NA Background: The user is facing the issue…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to change the Right Click Pop Up Menu Pop Up time - OpenUtilities Substation
Satish Saptasagar
Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.00.XX.XX to 10.09.X2.XX Environment: NA Area: Platform Support Subarea: NA Background: Right Click in Substation is used…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to change the Right Click Pop Up Menu Pop Up time
Satish Saptasagar
Product(s): Promis.e CONNECT Edition Version(s): 10.00.XX.XX to 10.06.XX.XX Environment: NA Area: Platform Support Subarea: NA Background: Right Click in Promis.e is used by user as Reset…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to do Restore Platform default in Promis.e CONNECT
Satish Saptasagar
Product(s): PROMIS.E CONNECT Edition Version(s): 10.00.XX.XX to 10.06.XX.XX Environment: N/A Area: Power Platform Support Subarea: Problem Description Certain dialogs or toolboxes will not…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to Create Custom Icon in OpenUtilities Substation
Satish Saptasagar
Product(s): OpenUtilities Substation Version(s): 10.00.XX.XX to 10.08.XX.XX Environment: N/A Area: Power Platform Customization Subarea: Background: The Custom Icon can be used by users to…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
HOW TO CREATE CUSTOM ICON IN PROMISE
Satish Saptasagar
Product(s): Promise CONNECT Edition Version(s): 10.00.XX.XX to 10.06.XX.XX Environment: N/A Area: Power Platform Customization Subarea: Background: The Custom Icon can be used by users to…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
How to do Restore Platform Defaults in OpenUtilities Substation CONNECT
Satish Saptasagar
Product(s): OpenUtilities Substation CONNECT Version(s): 10.00.XX.XX to 10.07.XX.XX Environment: N/A Area: Power Platform Support Subarea: N/A Background Certain dialogs or toolboxes will not…
over 3 years ago
OpenUtilities
OpenUtilities Wiki
Red insertion point arrows visible on exported DWG
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Reports_Output Features Subarea: N/A Problem Description On DWG files resulting from exporting…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Customizing the Interface - CONNECT Edition
Siddharaj Talawar
Product(s): Bentley Substation Version(s): 10.00.00.232 Environment: N/A Area: PowerPlatform Support Subarea: N/A Background If using a V8i (08.11.xx.xx) version of the software, see the Customizing…
over 3 years ago
OpenUtilities
OpenUtilities Wiki
Inserting Elements By Coordinates
Satish Saptasagar
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: PowerPlatform Support Subarea: N/A "How to insert macros at 0,0 or other X, Y coordinates?" …
over 3 years ago
OpenUtilities
OpenUtilities Wiki
Off-grid wires and symbols
Satish Saptasagar
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.12.xx Environment: Standalone Area: PowerPlatform Support Subarea: N/A Problem Description Symbols and wires that were inserted…
over 3 years ago
OpenUtilities
OpenUtilities Wiki
Printing With promis.e V8i On MicroStation
Matt_P
Product(s): Promis.e Version(s): 08.11.05.91 Environment: N/A Area: Print_Publish Features Subarea: Printing_Plotting Important: Since the release of promis.e V8i 08.11.07.82 (Service Pack 1…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Inserting Tables
Satish Saptasagar
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.12.140 Environment: N/A Area: PowerPlatform Support Subarea: N/A Background It is sometimes necessary to display data from…
over 3 years ago
OpenUtilities
OpenUtilities Wiki
Unreadable or disappearing elements upon selection
Satish Saptasagar
Product(s): Promis.e, Bentley Substation Version(s): 08.11.xx.xx Environment: N/A Area: PowerPlatform Support Subarea: N/A Problem Description When an item in a design file (drawing) is selected…
over 3 years ago
OpenUtilities
OpenUtilities Wiki
Assign actions to function keys
Siddharaj Talawar
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: PowerPlatform Support Subarea: N/A Background Frequently used actions or toggles can be assigned…
over 3 years ago
OpenUtilities
OpenUtilities Wiki
View related content from anywhere