    • Error - Object Reference .... Boolean IsPolywire - Promis.e CONNECT

      Satish Saptasagar
      Satish Saptasagar
      Product(s): Promis.e CONNECT Edition Version(s): 10.00.XX.XX to 10.09.XX.XX Environment: NA Area: Wiring Features Subarea: Wiring Error Background: The below Error sometimes can be seen when…
      • over 1 year ago
      • OpenUtilities
      • OpenUtilities Wiki
    • How to do Auto Wire numbering match to the Terminals

      Avanti Khandalkar
      Avanti Khandalkar
      Product(s): Promis.e, Bentley Substation Version(s): Connect Environment: N/A Area: Wire Numbering Subarea: Add Wire Label Background In below you can see that Wire number (assigned using…
      • over 3 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • How to Configure Wire Label in Promis.e CONNECT and Bentley Substation CONNECT

      Avanti Khandalkar
      Avanti Khandalkar
      Product(s): Promis.e, Bentley Substation Version(s): 10.02.00.29 Environment: N/A Area: Wire Numbering Subarea: Modify Wire Label After assigning a wire number, how to configure Wire Label in…
      • over 3 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Automatic Wire Number Scheme (Odd & Even) - Substation CONNECT

      Satish Saptasagar
      Satish Saptasagar
      Product(s): Bentley Substation CONNECT Version(s): 10.04.XX.XX Environment: N/A Area: Wire Numbering Subarea: Automatic Wire numbering Background: The Automatic Wire Number dialog enables users…
      • over 4 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Automatic Wire Number - Wire Number - Substation CONNECT

      Satish Saptasagar
      Satish Saptasagar
      Automatic Wire Number - Wire Number - Substation CONNECT
      • over 4 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Wire Numbering - Substation CONNECT

      Satish Saptasagar
      Satish Saptasagar
      Wire Numbering - Substation CONNECT
      • over 4 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Automatic Wire Number Scheme (Odd & Even) - Promis.e CONNECT

      Scott Walker
      Scott Walker
      Product(s): Promis.e CONNECT Version(s): 10.02.00.XX Environment: N/A Area: Wire Numbering Subarea: Automatic Wire Number Background: The Automatic Wire Number dialog enables users to automatically…
      • over 4 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Wire Numbering - Promis.e CONNECT

      Satish Saptasagar
      Satish Saptasagar
      Wire Numbering - Promis.e CONNECT
      • over 4 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • SS7 Wire management - Part 2

      Richard Derengowski
      Richard Derengowski
      New wire management functionality in SELECTseries 7 of promis.e and Bentley Substation. Part 2 of 2 parts.
      • wires part 2.mp4
      • View
      • Hide
      • over 10 years ago
      • OpenUtilities
      • Promis.e | OpenUtilities Substation Files
    • SS7 Wire management - Part 1

      Richard Derengowski
      Richard Derengowski
      New wire management functionality in SELECTseries 7 of promis.e and Bentley Substation. Part 1 of 2 parts.
      • wires part 1.mp4
      • View
      • Hide
      • over 10 years ago
      • OpenUtilities
      • Promis.e | OpenUtilities Substation Files
    • Nothing happens when using Automatic Wire Numbering

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.12.140 Environment: N/A Area: Wire Numbering Subarea: Automatic Wire Numbering Problem Description When trying to use Automatic…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • How to Print Wirelabels

      Waqar Mukarram
      Waqar Mukarram
      Hi, I would like to print the "wiring labels" for the wires that I am using in my project as well their quantities. Is there any way to do that in Promis-E? Preferably I would like to export them to an excel file or a notepad file.
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Substation | Promis.e Forum
    • Panduit Labels

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Reports_Output Features Subarea: Reporting Background The Panduit Labels tool generates a list…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Make wire number appear on other segments

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Wire Numbering Subarea: Add Wire Label After assigning a wire number to a potential, how do I…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Make gauge and color appear with wire numbers

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Administration Features Subarea: Options How do I make gauge and color or other wire properties…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Cant use same wire number even if installation and location is different. Is it even possible?

      John Le
      John Le
      I cant seem to use the same wire tag even if I change the installation and location to be different, shown in the picture below. I was assuming wire tags work like device IDs where you can have the same device ID if you have different installation/locations…
      • Answered
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Substation | Promis.e Forum
    • Problems associated with offline pages

      Satish Saptasagar
      Satish Saptasagar
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Project Management Subarea: Project Manager Problem Description Various undesirable behavior…
      • over 3 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Wire Tag Installation and Location Fields

      Matt_P
      Matt_P
      Product(s): Promis.e, Substation Version(s): through 08.11.13.140 Environment: N/A Area: Wire Numbering Subarea: Automatic Wire Numbering How do you use the Installation and Location fields on…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Error - You must select a profile or use it as the same as option!

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): 08.11.13.140 Environment: N\A Area: Wire Numbering Subarea: Automatic Wire Numbering Error or Warning Message Warning You must select a…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Wire number based on Device ID

      adamh1
      adamh1
      Hello! Promise SS8 08.11.13.57. Looking for a possibility to (automatically) build the wire number based on the Device ID (TargetDevice in the Wiring Manager) of the device it connects to. Not terminal, not PLC, but the instrument. Closest I cam is…
      • over 6 years ago
      • OpenUtilities
      • OpenUtilities Substation | Promis.e Forum
    • When to Add Wire Numbers

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): All Environment: N/A Area: Wire Numbering Subarea: Automatic Wire Numbering When is the best stage of project design to assign wire numbers…
      • over 6 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Wire numbers not in the correct format

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.73 Environment: N/A Area: Wire Numbering Subarea: Automatic Wire Numbering Problem Description Wire tags, also known as…
      • over 6 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Promis-e has developed a couple of issues?

      Alan Lumley
      Alan Lumley
      Promis-e has developed a couple of issues 1 – if I open a schematic all of the wire numbers disappear 2 – if I select a wire, I cannot extend it Previously I was able to select a wire, then select an end, then stretch the wire Regards…
      • over 7 years ago
      • OpenUtilities
      • OpenUtilities Substation | Promis.e Forum
    • Question marks in wire numbers

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.96 Environment: N\A Area: Wire Numbering Subarea: Modify Wire Label Problem Description Why are question marks appearing…
      • over 6 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Automatic Wire Number

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.73 Environment: N/A Area: Wire Numbering Subarea: Automatic Wire Numbering Background The Automatic Wire Number dialog…
      • over 6 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • View related content from anywhere
    • More
    • Cancel
    >
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies