After assigning values to symbol text on a symbol, the values do not transfer to other symbols for the device.
Or, after importing devices using "Import spreadsheets into BOM" on the BOM Explorer tab of Project Manager, the symbol text specified on the spreadsheet is not retained when the symbol for an imported device is inserted.
To share symbol text between symbols, ensure the "Shared Value" check box(es) are enabled for the attributes in question.
These settings are stored in the Multi_Language_UI.mdb file, typically found in "\promis-e Data\Databases\" or "\Substation Data\Databases\".
If the settings appear to have been reset, the software could be configured to use a different data folder or Language Database than previously used (local instead of network, for example) or the Multi_Language_UI.mdb file may have been overwritten.