Error - Session will timeout in 2 minutes


 Product(s):Promis.e, Bentley Substation
 Version(s):through 08.11.12.137
 Environment:N\A
 Area:Licensing
 Subarea:N\A

Error or Warning Message

The following message or similar appears after about 13 minutes of use, but the License Management Tool indicates the product is Activated.

Information
This session of promis-e V8i (SELECTseries 7) will timeout in
2 minutes. To activate this product please refer to promise
Help or contact your system administrator

After the two minutes expire, the application closes.

Explanation

Promis.e and Bentley Substation do not have a 15 minute trial mode. The above message can occur when the software is prevented from starting normally and using its license.

How to Avoid

Do not alter a .ucf file try to make the software start as a form of plain MicroStation

Do not specify the following in a .ucf file:

MS_INITAPPS =
MS_DGNAPPS =

The untitled.ucf file supplied with the software does not include the above lines. The .ucf files would be stored in the Workspace\Users folder, which is typically

C:\ProgramData\Bentley\promise V8i\WorkSpace\Users\

C:\ProgramData\Bentley\Substation V8i\WorkSpace\Users

Reinstall

In one case, no .ucf file was modified as described above. In that case performing a [[Clean Installation]] resolved the issue.

 Original Author:Matt_P