<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>ProjectWise dialog does not appear for attaching reference, opening file</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>ProjectWise dialog does not appear for attaching reference, opening file</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file</link><pubDate>Tue, 15 May 2018 19:29:49 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:27ba1b8c-97f0-42f1-bb83-e4cf4bcb5bca</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file#comments</comments><description>Current Revision posted to OpenUtilities Wiki by Matt_P on 5/15/2018 7:29:49 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation, Promis.e&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.13.140&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ProjectWise Integration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;&lt;em&gt;When I&amp;nbsp;try to attach&amp;nbsp;a file as a reference, the standard&amp;nbsp;file system&amp;nbsp;explorer dialog opens instead of the&lt;/em&gt; Select CAD File&lt;em&gt; dialog, so I cannot browse files stored in ProjectWise.&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;The problem may also occur with &lt;strong&gt;File &amp;gt; Open&lt;/strong&gt; or other tools.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;Ensure the [[Install the ProjectWise custom module for ProjectWise Explorer|custom module for ProjectWise Explorer is installed]] and the &lt;strong&gt;[[Setup]] &amp;gt; ProjectWise&lt;/strong&gt; dialog is configured properly.&lt;/p&gt;
&lt;p&gt;If ProjectWise integration is installed and configured properly try the following.&lt;/p&gt;
&lt;h3&gt;Option 1&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Open &lt;strong&gt;[[Setup]] &lt;/strong&gt;and select the &lt;strong&gt;ProjectWise&lt;/strong&gt; tab.&lt;/li&gt;
&lt;li&gt;Clear the &lt;strong&gt;Enable ProjectWise integration &lt;/strong&gt;check box, click &lt;strong&gt;OK&lt;/strong&gt;.&lt;/li&gt;
&lt;li&gt;Close Bentley Substation/Promise.&lt;/li&gt;
&lt;li&gt;Open Bentley Substation/Promis.e.&lt;/li&gt;
&lt;li&gt;Open &lt;strong&gt;[[Setup]] &lt;/strong&gt;and select the &lt;strong&gt;ProjectWise&lt;/strong&gt; tab.&lt;/li&gt;
&lt;li&gt;Set the &lt;strong&gt;Enable ProjectWise integration &lt;/strong&gt;check box, click &lt;strong&gt;OK&lt;/strong&gt;.&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;Option 2&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Select &lt;strong&gt;Workspace &amp;gt; Configuration&lt;/strong&gt; from the main pull down menus in Bentley Substation/Promis.e.&lt;/li&gt;
&lt;li&gt;Look for a &lt;strong&gt;PW_DISABLE_INTEGRATION&lt;/strong&gt; variable. If it exists and is set to 1, that may be the problem. This would be coming from the &lt;strong&gt;pw.cfg &lt;/strong&gt;file, found in a path like:&lt;br /&gt;C:\Program Files (x86)\Bentley\Substation V8i\Substation\config\appl\&lt;br /&gt;or&lt;br /&gt;C:\Program Files (x86)\Bentley\promise V8i\promise\config\appl&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;There is logic in the &lt;strong&gt;pw.cfg&lt;/strong&gt; file&amp;nbsp;that&amp;nbsp;sets PW_DISABLE_INTEGRATION if it does not find what it likes. The following procedure resolved the problem for one user.&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Open pw.cfg in a text editor such as Notepad.&lt;/li&gt;
&lt;li&gt;Comment out the &lt;span style="font-family:courier new,courier;"&gt;PW_DISABLE_INTEGRATION_FROM_DESKTOP=1&lt;/span&gt; line by inserting&amp;nbsp;a &lt;strong&gt;#&lt;/strong&gt; at the beginning of the line if one is not present already:&lt;br /&gt;&lt;span style="font-family:courier new,courier;"&gt;#PW_DISABLE_INTEGRATION_FROM_DESKTOP=1&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;Restart Bentley Substation/Promis.e&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;[[Install ProjectWise integration]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, Bentley Substation, en, ProjectWise integration&lt;/div&gt;
</description></item><item><title>ProjectWise dialog does not appear for attaching reference, opening file</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file/revision/4</link><pubDate>Tue, 15 May 2018 19:29:00 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:27ba1b8c-97f0-42f1-bb83-e4cf4bcb5bca</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file#comments</comments><description>Revision 4 posted to OpenUtilities Wiki by Matt_P on 5/15/2018 7:29:00 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation, Promis.e&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.13.140&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ProjectWise Integration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;&lt;em&gt;When I&amp;nbsp;try to attach&amp;nbsp;a file as a reference, the standard&amp;nbsp;file system&amp;nbsp;explorer dialog opens instead of the&lt;/em&gt; Select CAD File&lt;em&gt; dialog allowing me to browse files stored in ProjectWise.&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Problem may also occur with &lt;strong&gt;File &amp;gt; Open&lt;/strong&gt; or other tools.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;Ensure the [[Install the ProjectWise custom module for ProjectWise Explorer|custom module for ProjectWise Explorer is installed]] and the &lt;strong&gt;[[Setup]] &amp;gt; ProjectWise&lt;/strong&gt; dialog is configured properly.&lt;/p&gt;
&lt;p&gt;If ProjectWise integration is installed and configured properly try the following.&lt;/p&gt;
&lt;h3&gt;Option 1&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Open &lt;strong&gt;[[Setup]] &lt;/strong&gt;and select the &lt;strong&gt;ProjectWise&lt;/strong&gt; tab.&lt;/li&gt;
&lt;li&gt;Clear the &lt;strong&gt;Enable ProjectWise integration &lt;/strong&gt;check box, click &lt;strong&gt;OK&lt;/strong&gt;.&lt;/li&gt;
&lt;li&gt;Close Bentley Substation/Promise.&lt;/li&gt;
&lt;li&gt;Open Bentley Substation/Promis.e.&lt;/li&gt;
&lt;li&gt;Open &lt;strong&gt;[[Setup]] &lt;/strong&gt;and select the &lt;strong&gt;ProjectWise&lt;/strong&gt; tab.&lt;/li&gt;
&lt;li&gt;Set the &lt;strong&gt;Enable ProjectWise integration &lt;/strong&gt;check box, click &lt;strong&gt;OK&lt;/strong&gt;.&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;Option 2&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Select &lt;strong&gt;Workspace &amp;gt; Configuration&lt;/strong&gt; from the main pull down menus in Bentley Substation/Promis.e.&lt;/li&gt;
&lt;li&gt;Look for a &lt;strong&gt;PW_DISABLE_INTEGRATION&lt;/strong&gt; variable. If it exists and is set to 1, that may be the problem. This would be coming from the &lt;strong&gt;pw.cfg &lt;/strong&gt;file, found in a path like:&lt;br /&gt;C:\Program Files (x86)\Bentley\Substation V8i\Substation\config\appl\&lt;br /&gt;or&lt;br /&gt;C:\Program Files (x86)\Bentley\promise V8i\promise\config\appl&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;There is logic in the &lt;strong&gt;pw.cfg&lt;/strong&gt; file&amp;nbsp;that&amp;nbsp;sets PW_DISABLE_INTEGRATION if it does not find what it likes. The following procedure resolved the problem for one user.&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Open pw.cfg in a text editor such as Notepad.&lt;/li&gt;
&lt;li&gt;Comment out the &lt;span style="font-family:courier new,courier;"&gt;PW_DISABLE_INTEGRATION_FROM_DESKTOP=1&lt;/span&gt; line by inserting&amp;nbsp;a &lt;strong&gt;#&lt;/strong&gt; at the beginning of the line if one is not present already:&lt;br /&gt;&lt;span style="font-family:courier new,courier;"&gt;#PW_DISABLE_INTEGRATION_FROM_DESKTOP=1&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;Restart Bentley Substation/Promis.e&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;[[Install ProjectWise integration]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, Bentley Substation, en, ProjectWise integration&lt;/div&gt;
</description></item><item><title>ProjectWise dialog does not appear for attaching reference, opening file</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file/revision/3</link><pubDate>Tue, 24 Apr 2018 20:53:53 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:27ba1b8c-97f0-42f1-bb83-e4cf4bcb5bca</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file#comments</comments><description>Revision 3 posted to OpenUtilities Wiki by Matt_P on 4/24/2018 8:53:53 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation, Promis.e&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.12.140&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ProjectWise Integration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;&lt;em&gt;When I&amp;nbsp;try to attach&amp;nbsp;a file as a reference, the standard&amp;nbsp;file system&amp;nbsp;explorer dialog opens instead of a dialog allowing me to browse files stored in ProjectWise.&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Problem may also occur with &lt;strong&gt;File &amp;gt; Open&lt;/strong&gt; or other tools.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;Ensure the [[Install the ProjectWise custom module for ProjectWise Explorer|custom module for ProjectWise Explorer is installed]] and the &lt;strong&gt;[[Setup]] &amp;gt; ProjectWise&lt;/strong&gt; dialog is configured properly.&lt;/p&gt;
&lt;p&gt;If ProjectWise integration is installed and configured properly try the following.&lt;/p&gt;
&lt;h3&gt;Option 1&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Open &lt;strong&gt;[[Setup]] &lt;/strong&gt;and select the &lt;strong&gt;ProjectWise&lt;/strong&gt; tab.&lt;/li&gt;
&lt;li&gt;Clear the &lt;strong&gt;Enable ProjectWise integration &lt;/strong&gt;check box, click &lt;strong&gt;OK&lt;/strong&gt;.&lt;/li&gt;
&lt;li&gt;Close Bentley Substation/Promise.&lt;/li&gt;
&lt;li&gt;Open Bentley Substation/Promis.e.&lt;/li&gt;
&lt;li&gt;Open &lt;strong&gt;[[Setup]] &lt;/strong&gt;and select the &lt;strong&gt;ProjectWise&lt;/strong&gt; tab.&lt;/li&gt;
&lt;li&gt;Set the &lt;strong&gt;Enable ProjectWise integration &lt;/strong&gt;check box, click &lt;strong&gt;OK&lt;/strong&gt;.&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;Option 2&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Select &lt;strong&gt;Workspace &amp;gt; Configuration&lt;/strong&gt; from the main pull down menus in Bentley Substation/Promis.e.&lt;/li&gt;
&lt;li&gt;Look for a &lt;strong&gt;PW_DISABLE_INTEGRATION&lt;/strong&gt; variable. If it exists and is set to 1, that may be the problem. This would be coming from the &lt;strong&gt;pw.cfg &lt;/strong&gt;file, found in a path like:&lt;br /&gt;C:\Program Files (x86)\Bentley\Substation V8i\Substation\config\appl\&lt;br /&gt;or&lt;br /&gt;C:\Program Files (x86)\Bentley\promise V8i\promise\config\appl&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;There is logic in the &lt;strong&gt;pw.cfg&lt;/strong&gt; file&amp;nbsp;that&amp;nbsp;sets PW_DISABLE_INTEGRATION if it does not find what it likes. The following procedure resolved the problem for one user.&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Open pw.cfg in a text editor such as Notepad.&lt;/li&gt;
&lt;li&gt;Comment out the &lt;span style="font-family:courier new,courier;"&gt;PW_DISABLE_INTEGRATION_FROM_DESKTOP=1&lt;/span&gt; line by inserting&amp;nbsp;a &lt;strong&gt;#&lt;/strong&gt; at the beginning of the line if one is not present already:&lt;br /&gt;&lt;span style="font-family:courier new,courier;"&gt;#PW_DISABLE_INTEGRATION_FROM_DESKTOP=1&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;Restart Bentley Substation/Promis.e&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;[[Install ProjectWise integration]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, Bentley Substation, en, ProjectWise integration&lt;/div&gt;
</description></item><item><title>ProjectWise dialog does not appear for attaching reference, opening file</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file/revision/2</link><pubDate>Fri, 15 Jan 2016 16:55:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:27ba1b8c-97f0-42f1-bb83-e4cf4bcb5bca</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file#comments</comments><description>Revision 2 posted to OpenUtilities Wiki by Matt_P on 1/15/2016 4:55:44 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation, promis.e&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.12.137&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ProjectWise Integration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;&lt;em&gt;When I&amp;nbsp;try to attach&amp;nbsp;a file as a reference, the standard&amp;nbsp;file system&amp;nbsp;explorer dialog opens instead of a dialog allowing me to browse files stored in ProjectWise.&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Problem may also occur with &lt;strong&gt;File &amp;gt; Open&lt;/strong&gt; or other tools.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;Ensure ProjectWise integration is [[Install ProjectWise integration|installed]] and configured properly on the [[Setup]] dialog.&lt;/p&gt;
&lt;p&gt;If ProjectWise integration is installed and configured properly, check &lt;strong&gt;Workspace &amp;gt; Configuration&lt;/strong&gt; in Bentley Substation/promis.e.&lt;/p&gt;
&lt;p&gt;Look for a &lt;strong&gt;PW_DISABLE_INTEGRATION&lt;/strong&gt; variable. If it exists and is set to 1, that may be the problem. This would be coming from the &lt;strong&gt;pw.cfg &lt;/strong&gt;file, found in a path like:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;C:\Program Files (x86)\Bentley\Substation V8i\Substation\config\appl\&lt;/p&gt;
&lt;p&gt;or&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;C:\Program Files (x86)\Bentley\promise V8i\promise\config\appl&lt;/p&gt;
&lt;p&gt;There is logic in the &lt;strong&gt;pw.cfg&lt;/strong&gt; file&amp;nbsp;that&amp;nbsp;sets PW_DISABLE_INTEGRATION if it does not find what it likes. The following procedure resolved the problem for one user.&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Open pw.cfg in a text editor such as Notepad.&lt;/li&gt;
&lt;li&gt;Comment out the &lt;span style="font-family:courier new,courier;"&gt;PW_DISABLE_INTEGRATION_FROM_DESKTOP=1&lt;/span&gt; line by inserting&amp;nbsp;a &lt;strong&gt;#&lt;/strong&gt; at the beginning of the line if one is not present already:&lt;br /&gt;&lt;span style="font-family:courier new,courier;"&gt;#PW_DISABLE_INTEGRATION_FROM_DESKTOP=1&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;Restart Bentley Substation/promis.e&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;[[Install ProjectWise integration]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" height="60" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, Bentley Substation, en, SELECTsupport, ProjectWise integration&lt;/div&gt;
</description></item><item><title>ProjectWise dialog does not appear for attaching reference, opening file</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file/revision/1</link><pubDate>Fri, 15 Jan 2016 16:46:17 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:27ba1b8c-97f0-42f1-bb83-e4cf4bcb5bca</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/26301/projectwise-dialog-does-not-appear-for-attaching-reference-opening-file#comments</comments><description>Revision 1 posted to OpenUtilities Wiki by Matt_P on 1/15/2016 4:46:17 PM&lt;br /&gt;
&lt;table style="border-top:#dce5f0 0px solid;border-right:#dce5f0 0px solid;border-bottom:#dce5f0 0px solid;border-left:#dce5f0 0px solid;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation, promis.e&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.12.137 &lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ProjectWise Integration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;&lt;em&gt;When I&amp;nbsp;try to attach&amp;nbsp;a file as a reference, the standard&amp;nbsp;file system&amp;nbsp;explorer dialog opens instead of a dialog allowing me to browse files stored in ProjectWise.&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Problem may also occur with &lt;strong&gt;File &amp;gt; Open&lt;/strong&gt; or other tools.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;Ensure ProjectWise integration is [[Install ProjectWise integration|installed]] and configured properly on the [[Setup]] dialog.&lt;/p&gt;
&lt;p&gt;If ProjectWise integration is installed and configured properly, check &lt;strong&gt;Workspace &amp;gt; Configuration&lt;/strong&gt; in Bentley Substation/promis.e.&lt;/p&gt;
&lt;p&gt;Look for a &lt;strong&gt;PW_DISABLE_INTEGRATION&lt;/strong&gt; variable. If it exists and is set to 1, that may be the problem. This would be coming from the &lt;strong&gt;pw.cfg &lt;/strong&gt;file, found in a path like:&lt;/p&gt;
&lt;p&gt;C:\Program Files (x86)\Bentley\Substation V8i\Substation\config\appl\&lt;/p&gt;
&lt;p&gt;or &lt;/p&gt;
&lt;p&gt;C:\Program Files (x86)\Bentley\promise V8i\promise\config\appl&lt;/p&gt;
&lt;p&gt;There is logic in the &lt;strong&gt;pw.cfg&lt;/strong&gt; file&amp;nbsp;that&amp;nbsp;sets PW_DISABLE_INTEGRATION if it does not find what it likes. The following procedure resolved the problem for one user.&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Open pw.cfg in a text editor such as Notepad.&lt;/li&gt;
&lt;li&gt;Comment out the PW_DISABLE_INTEGRATION_FROM_DESKTOP=1 line by inserting&amp;nbsp;a &lt;strong&gt;#&lt;/strong&gt; at the beginning of the line if one is not present already. &lt;/li&gt;
&lt;li&gt;Restart Bentley Substation/promis.e &lt;/li&gt;&lt;/ol&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;[[Install ProjectWise integration]]&lt;/p&gt;&lt;img style="border-left-width:0px;border-right-width:0px;border-bottom-width:0px;border-top-width:0px;" alt=" " src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" /&gt; 
&lt;table style="border-top:#dce5f0 0px solid;border-right:#dce5f0 0px solid;border-bottom:#dce5f0 0px solid;border-left:#dce5f0 0px solid;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, Bentley Substation, en, SELECTsupport, ProjectWise integration&lt;/div&gt;
</description></item></channel></rss>