<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Parts missing from Insert Substation Objects</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/28549/parts-missing-from-insert-substation-objects</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Parts missing from Insert Substation Objects</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/28549/parts-missing-from-insert-substation-objects</link><pubDate>Mon, 17 Dec 2018 18:25:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ae374078-8b3b-447a-8ca9-a5cfb3330dc0</guid><dc:creator>Sarvesh Kulkarni</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/28549/parts-missing-from-insert-substation-objects#comments</comments><description>Current Revision posted to OpenUtilities Wiki by Sarvesh Kulkarni on 12/17/2018 6:25:28 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 10.02.00.31&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;3D Layout Features&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Insert Substation Objects&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;After selecting the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool, expected parts are not listed on the resulting dialog for insertion.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;There are various methods of filter the results on the dialog. Make sure the desired part numbers are not filtered out of the results.&lt;/p&gt;
&lt;h3&gt;Select the appropriate Part Type filter&lt;/h3&gt;
&lt;p&gt;&lt;strong&gt;In Bentley Substation CONNECT and V8i SELECTseries 8&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &lt;strong&gt;Single&lt;/strong&gt; filter will show only part numbers that have a value of &lt;strong&gt;SGL&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Linear &lt;/strong&gt;filter will show only part numbers that have a value of &lt;strong&gt;X-X&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Repeating&lt;/strong&gt; filter will show only part numbers that have a value if &lt;strong&gt;REP&lt;/strong&gt; in the Part_Type field.&lt;br /&gt;&lt;br /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-62/pastedimage1545071048303v2.png" alt=" " /&gt;&lt;br /&gt;&lt;br /&gt;Use the &lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool to insert cables and bus parts, which should have a Part_Type value of &lt;strong&gt;VAR&lt;/strong&gt;.&lt;br /&gt;&lt;br /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-62/pastedimage1545071112999v3.png" alt=" " /&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;strong&gt;In Bentley Substation V8i SELECTseries 7 and earlier&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &lt;strong&gt;Single &lt;/strong&gt;filter will show only part numbers that have a value of &lt;strong&gt;SGL&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Variable&lt;/strong&gt; filter will show only part numbers that have a value of &lt;strong&gt;VAR&lt;/strong&gt; in the Part_Type field.&lt;br /&gt;The&amp;nbsp;&lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool&amp;nbsp;can also be used to insert cables and bus parts, which should have a Part_Type value of VAR&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Repeating&lt;/strong&gt; filter will show only part numbers that have a value if &lt;strong&gt;REP&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Values for Part_Type and other part number fields can be modified using [[Parts Database Manager]]. After modifying the records of part numbers used in the project, it may be necessary to update the project with the new information. See [[Parts database changes not reflected in project]].&lt;/p&gt;
&lt;h3&gt;Other filters&lt;/h3&gt;
&lt;p&gt;Try clearing the &lt;strong&gt;Apply project filter&lt;/strong&gt; check box in the &lt;strong&gt;Filters&lt;/strong&gt; pane. If the desired parts appear, consider modifying the project filter ([[Options]] &lt;strong&gt;&amp;gt; Project Options &amp;gt; Part Number Settings &amp;gt; General &amp;gt; Edit Filter&lt;/strong&gt;).&lt;/p&gt;
&lt;p&gt;Try clearing the &lt;strong&gt;Only parts with symbol for current drawing mode&lt;/strong&gt; check box in the &lt;strong&gt;Filters&lt;/strong&gt; pane. If the desired parts appear, symbols can be assigned to the 3D_Layout_Symbol field of part number records using the [[Parts Database Manager]].&lt;/p&gt;
&lt;p&gt;Custom, word-based filters can be created in the &lt;strong&gt;Filters&lt;/strong&gt; pane. Try deleting or modifying&amp;nbsp;filters found here.&lt;/p&gt;
&lt;p&gt;Try selecting the &amp;quot;All Parts&amp;quot; item in the &lt;strong&gt;Part Tree&lt;/strong&gt; pane. If the desired parts are visible with &amp;quot;All Parts&amp;quot; selected but not when a sub-category is selected, the part number record(s) can be modified using [[Parts Database Manager]] so the part number fits the desired category. The part number fields used to categorize the Part Tree are specified in [[Options]] &lt;strong&gt;&amp;gt; System Options &amp;gt; Part Number Settings&lt;/strong&gt;.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[Parts database changes not reflected in project]]&lt;/p&gt;
&lt;p&gt;[[Part_Type filter values]]&lt;/p&gt;
&lt;p&gt;[[Part numbers missing from Insert Cable/Bus Object]]&lt;/p&gt;
&lt;p&gt;[[Quick Filtering in the Parts Database Manager]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: 3D Layout Features, Bentley Substation, en, Insert Substation Objects, Problem Solving&lt;/div&gt;
</description></item><item><title>Parts missing from Insert Substation Objects</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/28549/parts-missing-from-insert-substation-objects/revision/3</link><pubDate>Mon, 17 Dec 2018 18:25:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ae374078-8b3b-447a-8ca9-a5cfb3330dc0</guid><dc:creator>Sarvesh Kulkarni</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/28549/parts-missing-from-insert-substation-objects#comments</comments><description>Revision 3 posted to OpenUtilities Wiki by Sarvesh Kulkarni on 12/17/2018 6:25:28 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 10.02.00.31&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;3D Layout Features&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Insert Substation Objects&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;After selecting the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool, expected parts are not listed on the resulting dialog for insertion.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;There are various methods of filter the results on the dialog. Make sure the desired part numbers are not filtered out of the results.&lt;/p&gt;
&lt;h3&gt;Select the appropriate Part Type filter&lt;/h3&gt;
&lt;p&gt;&lt;strong&gt;In Bentley Substation CONNECT and V8i SELECTseries 8&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &lt;strong&gt;Single&lt;/strong&gt; filter will show only part numbers that have a value of &lt;strong&gt;SGL&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Linear &lt;/strong&gt;filter will show only part numbers that have a value of &lt;strong&gt;X-X&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Repeating&lt;/strong&gt; filter will show only part numbers that have a value if &lt;strong&gt;REP&lt;/strong&gt; in the Part_Type field.&lt;br /&gt;&lt;br /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-26/pastedimage1545071048303v2.png" alt=" " /&gt;&lt;br /&gt;&lt;br /&gt;Use the &lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool to insert cables and bus parts, which should have a Part_Type value of &lt;strong&gt;VAR&lt;/strong&gt;.&lt;br /&gt;&lt;br /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-26/pastedimage1545071112999v3.png" alt=" " /&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;strong&gt;In Bentley Substation V8i SELECTseries 7 and earlier&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &lt;strong&gt;Single &lt;/strong&gt;filter will show only part numbers that have a value of &lt;strong&gt;SGL&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Variable&lt;/strong&gt; filter will show only part numbers that have a value of &lt;strong&gt;VAR&lt;/strong&gt; in the Part_Type field.&lt;br /&gt;The&amp;nbsp;&lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool&amp;nbsp;can also be used to insert cables and bus parts, which should have a Part_Type value of VAR&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Repeating&lt;/strong&gt; filter will show only part numbers that have a value if &lt;strong&gt;REP&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Values for Part_Type and other part number fields can be modified using [[Parts Database Manager]]. After modifying the records of part numbers used in the project, it may be necessary to update the project with the new information. See [[Parts database changes not reflected in project]].&lt;/p&gt;
&lt;h3&gt;Other filters&lt;/h3&gt;
&lt;p&gt;Try clearing the &lt;strong&gt;Apply project filter&lt;/strong&gt; check box in the &lt;strong&gt;Filters&lt;/strong&gt; pane. If the desired parts appear, consider modifying the project filter ([[Options]] &lt;strong&gt;&amp;gt; Project Options &amp;gt; Part Number Settings &amp;gt; General &amp;gt; Edit Filter&lt;/strong&gt;).&lt;/p&gt;
&lt;p&gt;Try clearing the &lt;strong&gt;Only parts with symbol for current drawing mode&lt;/strong&gt; check box in the &lt;strong&gt;Filters&lt;/strong&gt; pane. If the desired parts appear, symbols can be assigned to the 3D_Layout_Symbol field of part number records using the [[Parts Database Manager]].&lt;/p&gt;
&lt;p&gt;Custom, word-based filters can be created in the &lt;strong&gt;Filters&lt;/strong&gt; pane. Try deleting or modifying&amp;nbsp;filters found here.&lt;/p&gt;
&lt;p&gt;Try selecting the &amp;quot;All Parts&amp;quot; item in the &lt;strong&gt;Part Tree&lt;/strong&gt; pane. If the desired parts are visible with &amp;quot;All Parts&amp;quot; selected but not when a sub-category is selected, the part number record(s) can be modified using [[Parts Database Manager]] so the part number fits the desired category. The part number fields used to categorize the Part Tree are specified in [[Options]] &lt;strong&gt;&amp;gt; System Options &amp;gt; Part Number Settings&lt;/strong&gt;.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[Parts database changes not reflected in project]]&lt;/p&gt;
&lt;p&gt;[[Part_Type filter values]]&lt;/p&gt;
&lt;p&gt;[[Part numbers missing from Insert Cable/Bus Object]]&lt;/p&gt;
&lt;p&gt;[[Quick Filtering in the Parts Database Manager]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: 3D Layout Features, Bentley Substation, en, Insert Substation Objects, Problem Solving&lt;/div&gt;
</description></item><item><title>Parts missing from Insert Substation Objects</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/28549/parts-missing-from-insert-substation-objects/revision/2</link><pubDate>Wed, 20 Dec 2017 15:33:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ae374078-8b3b-447a-8ca9-a5cfb3330dc0</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/28549/parts-missing-from-insert-substation-objects#comments</comments><description>Revision 2 posted to OpenUtilities Wiki by Matt_P on 12/20/2017 3:33:27 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.13.140&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;3D Layout Features&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Insert Substation Objects&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;After selecting the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool, expected parts are not listed on the resulting dialog for insertion.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;There are various methods of filter the results on the dialog. Make sure the desired part numbers are not filtered out of the results.&lt;/p&gt;
&lt;h3&gt;Select the appropriate Part Type filter&lt;/h3&gt;
&lt;p&gt;&lt;strong&gt;In Bentley Substation V8i SELECTseries 8&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &lt;strong&gt;Single&lt;/strong&gt; filter will show only part numbers that have a value of &lt;strong&gt;SGL&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Linear &lt;/strong&gt;filter will show only part numbers that have a value of &lt;strong&gt;X-X&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Repeating&lt;/strong&gt; filter will show only part numbers that have a value if &lt;strong&gt;REP&lt;/strong&gt; in the Part_Type field.&lt;br /&gt;&lt;br /&gt;Use the &lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool to insert cables and bus parts, which should have a Part_Type value of &lt;strong&gt;VAR&lt;/strong&gt;.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;strong&gt;In Bentley Substation V8i SELECTseries 7 and earlier&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &lt;strong&gt;Single &lt;/strong&gt;filter will show only part numbers that have a value of &lt;strong&gt;SGL&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Variable&lt;/strong&gt; filter will show only part numbers that have a value of &lt;strong&gt;VAR&lt;/strong&gt; in the Part_Type field.&lt;br /&gt;The&amp;nbsp;&lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool&amp;nbsp;can also be used to insert cables and bus parts, which should have a Part_Type value of VAR&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Repeating&lt;/strong&gt; filter will show only part numbers that have a value if &lt;strong&gt;REP&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Values for Part_Type and other part number fields can be modified using [[Parts Database Manager]]. After modifying the records of part numbers used in the project, it may be necessary to update the project with the new information. See [[Parts database changes not reflected in project]].&lt;/p&gt;
&lt;h3&gt;Other filters&lt;/h3&gt;
&lt;p&gt;Try clearing the &lt;strong&gt;Apply project filter&lt;/strong&gt; check box in the &lt;strong&gt;Filters&lt;/strong&gt; pane. If the desired parts appear, consider modifying the project filter ([[Options]] &lt;strong&gt;&amp;gt; Project Options &amp;gt; Part Number Settings &amp;gt; General &amp;gt; Edit Filter&lt;/strong&gt;).&lt;/p&gt;
&lt;p&gt;Try clearing the &lt;strong&gt;Only parts with symbol for current drawing mode&lt;/strong&gt; check box in the &lt;strong&gt;Filters&lt;/strong&gt; pane. If the desired parts appear, symbols can be assigned to the 3D_Layout_Symbol field of part number records using the [[Parts Database Manager]].&lt;/p&gt;
&lt;p&gt;Custom, word-based filters can be created in the &lt;strong&gt;Filters&lt;/strong&gt; pane. Try deleting or modifying&amp;nbsp;filters found here.&lt;/p&gt;
&lt;p&gt;Try selecting the &amp;quot;All Parts&amp;quot; item in the &lt;strong&gt;Part Tree&lt;/strong&gt; pane. If the desired parts are visible with &amp;quot;All Parts&amp;quot; selected but not when a sub-category is selected, the part number record(s) can be modified using [[Parts Database Manager]] so the part number fits the desired category. The part number fields used to categorize the Part Tree are specified in [[Options]] &lt;strong&gt;&amp;gt; System Options &amp;gt; Part Number Settings&lt;/strong&gt;.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[Parts database changes not reflected in project]]&lt;/p&gt;
&lt;p&gt;[[Part_Type filter values]]&lt;/p&gt;
&lt;p&gt;[[Part numbers missing from Insert Cable/Bus Object]]&lt;/p&gt;
&lt;p&gt;[[Quick Filtering in the Parts Database Manager]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: 3D Layout Features, Bentley Substation, en, Insert Substation Objects, Problem Solving&lt;/div&gt;
</description></item><item><title>Parts missing from Insert Substation Objects</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/28549/parts-missing-from-insert-substation-objects/revision/1</link><pubDate>Wed, 25 May 2016 15:52:54 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ae374078-8b3b-447a-8ca9-a5cfb3330dc0</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/28549/parts-missing-from-insert-substation-objects#comments</comments><description>Revision 1 posted to OpenUtilities Wiki by Matt_P on 5/25/2016 3:52:54 PM&lt;br /&gt;
&lt;table style="border-top:#dce5f0 0px solid;border-right:#dce5f0 0px solid;border-bottom:#dce5f0 0px solid;border-left:#dce5f0 0px solid;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;3D Layout Features&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Insert Substation Objects&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;After selecting the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool, expected parts are not listed on the resulting dialog for insertion. &lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;There are various methods of filter the results on the dialog. Make sure the desired part numbers are not filtered out of the results.&lt;/p&gt;
&lt;h3&gt;Select the appropriate Part Type filter&lt;/h3&gt;
&lt;p&gt;&lt;strong&gt;In Bentley Substation V8i SELECTseries 8&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &lt;strong&gt;Single&lt;/strong&gt; filter will show only part numbers that have a value of &lt;strong&gt;SGL&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Linear &lt;/strong&gt;filter will show only part numbers that have a value of &lt;strong&gt;X-X&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Repeating&lt;/strong&gt; filter will show only part numbers that have a value if &lt;strong&gt;REP&lt;/strong&gt; in the Part_Type field.&lt;br /&gt;&lt;br /&gt;Use the &lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool to insert cables and bus parts, which should have a Part_Type value of &lt;strong&gt;VAR&lt;/strong&gt;.&lt;/li&gt;&lt;/ul&gt;
&lt;p&gt;&lt;strong&gt;In Bentley Substation V8i SELECTseries 7 and earlier&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The &lt;strong&gt;Single &lt;/strong&gt;filter will show only part numbers that have a value of &lt;strong&gt;SGL&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Variable&lt;/strong&gt; filter will show only part numbers that have a value of &lt;strong&gt;VAR&lt;/strong&gt; in the Part_Type field.&lt;br /&gt;The&amp;nbsp;&lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool&amp;nbsp;can also be used to insert cables and bus parts, which should have a Part_Type value of VAR&lt;/li&gt;
&lt;li&gt;The &lt;strong&gt;Repeating&lt;/strong&gt; filter will show only part numbers that have a value if &lt;strong&gt;REP&lt;/strong&gt; in the Part_Type field.&lt;/li&gt;&lt;/ul&gt;
&lt;p&gt;Values for Part_Type and other part number fields can be modified using [[Parts Database Manager]].&lt;/p&gt;
&lt;h3&gt;Other filters&lt;/h3&gt;
&lt;p&gt;Try clearing the &lt;strong&gt;Apply project filter&lt;/strong&gt; check box in the &lt;strong&gt;Filters&lt;/strong&gt; pane. If the desired parts appear, consider modifying the project filter ([[Options]] &lt;strong&gt;&amp;gt; Project Options &amp;gt; Part Number Settings &amp;gt; General &amp;gt; Edit Filter&lt;/strong&gt;).&lt;/p&gt;
&lt;p&gt;Try clearing the &lt;strong&gt;Only parts with symbol for current drawing mode&lt;/strong&gt; check box in the &lt;strong&gt;Filters&lt;/strong&gt; pane. If the desired parts appear, symbols can be assigned to the 3D_Layout_Symbol field of part number records using the [[Parts Database Manager]].&lt;/p&gt;
&lt;p&gt;Custom, word-based filters can be created in the &lt;strong&gt;Filters&lt;/strong&gt; pane. Try deleting or modifying&amp;nbsp;filters found here.&lt;/p&gt;
&lt;p&gt;Try selecting the &amp;quot;All Parts&amp;quot; item in the &lt;strong&gt;Part Tree&lt;/strong&gt; pane. If the desired parts are visible with &amp;quot;All Parts&amp;quot; selected but not when a sub-category is selected, the part number record(s) can be modified using [[Parts Database Manager]] so the part number fits the desired category. The part number fields used to categorize the Part Tree are specified in [[Options]] &lt;strong&gt;&amp;gt; System Options &amp;gt; Part Number Settings&lt;/strong&gt;.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[Quick Filtering in the Parts Database Manager]]&lt;/p&gt;
&lt;p&gt;[[Part numbers missing from Insert Cable/Bus Object]]&lt;/p&gt;&lt;img style="border-left-width:0px;border-right-width:0px;border-bottom-width:0px;border-top-width:0px;" alt=" " src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" /&gt; 
&lt;table style="border-top:#dce5f0 0px solid;border-right:#dce5f0 0px solid;border-bottom:#dce5f0 0px solid;border-left:#dce5f0 0px solid;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: 3D Layout Features, Bentley Substation, en, Insert Substation Objects, SELECTsupport&lt;/div&gt;
</description></item></channel></rss>