<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Part_Type filter values</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Part_Type filter values</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values</link><pubDate>Tue, 12 Jun 2018 14:39:22 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:98ccc54e-005e-400f-9935-ac31433e1d12</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values#comments</comments><description>Current Revision posted to OpenUtilities Wiki by Matt_P on 6/12/2018 2:39:22 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation, Promis.e&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.12.137 - 08.11.13.140&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Component Management&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Parts Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;This article provides a list of values that can be assigned to the &lt;strong&gt;Part_Type&lt;/strong&gt; field in part number records and the purpose of each value. &lt;strong&gt;Part_Type&lt;/strong&gt; values assigned to part numbers can be changed using &lt;strong&gt;[[Parts Database Manager]]&lt;/strong&gt;.&lt;/p&gt;
&lt;h1&gt;Part_Type values&lt;/h1&gt;
&lt;table border="2" cellpadding="1" cellspacing="2"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Part_Type&lt;/td&gt;
&lt;td&gt;SS8&lt;/td&gt;
&lt;td&gt;SS7&lt;/td&gt;
&lt;td&gt;Description&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;ACK&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;(Substation) Parts with a Part_Type value of &lt;strong&gt;ACK &lt;/strong&gt;will be considered accessory kits and listed on &lt;strong&gt;Accessory Kit Manager&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;DIN&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of &lt;strong&gt;DIN&lt;/strong&gt; will be available for use with the &lt;strong&gt;Insert DIN Rail &lt;/strong&gt;tool (&lt;em&gt;Draw Panel Layout Accessories &lt;/em&gt;dialog).&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGClamp&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;(Substation) By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGClamp&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Terminator&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForTerminator&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGROD&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;(Substation) By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGROD&amp;nbsp;&lt;/strong&gt;will be included in the parts available for selection in the &lt;strong&gt;Ground Rod&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog and will be available when using the &lt;strong&gt;Insert Rod Object&lt;/strong&gt; tool. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForGndRod&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWire&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;(Substation) By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGWire&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Wire type&lt;/strong&gt; field&amp;nbsp;on the &lt;em&gt;Place Grounding Grid dialog&lt;/em&gt;. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]]&lt;strong&gt; &amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWROD&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;(Substation) By default, parts with a Part_Type value of &lt;strong&gt;GGWROD&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Ground Rod connector&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWeldingGndRod&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWT&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;(Substation) By default, parts with a Part_Type value of &lt;strong&gt;GGWT&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 3-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 3-wire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWX&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;(Substation) By default, parts with a Part_Type value of &lt;strong&gt;GGWX&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 4-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 4-wire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;REP&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;(Substation) Parts with a Part_Type value of &lt;strong&gt;REP&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Repeating&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;SGL&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;(Substation) Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;SGL&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Single&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;TER&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Beginning with version 08.11.12.120, devices assigned a part number that has a Part_Type value of &lt;strong&gt;TER&lt;/strong&gt; will be included when the &lt;strong&gt;Terminal/Plug &lt;/strong&gt;filter is applied on&amp;nbsp;&lt;em&gt;Insert Symbol By Device ID. &lt;/em&gt;Prior to this version, the software relied on the symbol type of the schematic symbol to determine if the device should appear under the &lt;strong&gt;Devices&lt;/strong&gt; or &lt;strong&gt;Terminal/Plug&lt;/strong&gt; filter.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;VAR&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;
&lt;p&gt;(Substation) Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;VAR&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool. In SS7, parts with the &lt;strong&gt;VAR&lt;/strong&gt; part type were also available on &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; when the &amp;quot;Variable&amp;quot; filter was applied.&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;X-X&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;(Substation) Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;X-X&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Linear&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool. This value was not used prior to SS8. It is used in place of VAR which is now for cable and bus parts only.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style="margin-left:60px;"&gt;&lt;strong&gt;&amp;bull;&lt;/strong&gt; - indicates the Part_Type described in that row is used in the version indicated in that column.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[Part numbers missing from Insert Cable/Bus Object]]&lt;/p&gt;
&lt;p&gt;[[Parts missing from Insert Substation Objects]]&lt;/p&gt;
&lt;p&gt;[[Terminals, plugs missing from Insert Symbol By Device ID]]&lt;/p&gt;
&lt;p&gt;[[Parts Database Manager]]&lt;/p&gt;
&lt;p&gt;[[3D Layout Settings]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: parts database, 3D Layout Features, promis.e, Insert Cable_Bus Object, Insert Symbol By Part Number, Accessory Kit Manager, Grounding Grid, Bentley Substation, en, Insert Substation Objects, Place Grounding Grid, Component Management, Component Features&lt;/div&gt;
</description></item><item><title>Part_Type filter values</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values/revision/5</link><pubDate>Fri, 01 Dec 2017 16:04:14 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:98ccc54e-005e-400f-9935-ac31433e1d12</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values#comments</comments><description>Revision 5 posted to OpenUtilities Wiki by Matt_P on 12/1/2017 4:04:14 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation, Promis.e&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.12.137 - 08.11.13.140&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Component Management&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Parts Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;This article provides a list of values that can be assigned to the &lt;strong&gt;Part_Type&lt;/strong&gt; field in part number records and the purpose of each value. &lt;strong&gt;Part_Type&lt;/strong&gt; values assigned to part numbers can be changed using [[Parts Database Manager]].&lt;/p&gt;
&lt;h1&gt;Part_Type values&lt;/h1&gt;
&lt;table border="2" cellpadding="1" cellspacing="2"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Part_Type&lt;/td&gt;
&lt;td&gt;SS8&lt;/td&gt;
&lt;td&gt;SS7&lt;/td&gt;
&lt;td&gt;Description&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;DIN&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of &lt;strong&gt;DIN&lt;/strong&gt; will be available for use with the &lt;strong&gt;Insert DIN Rail &lt;/strong&gt;tool (&lt;em&gt;Draw Panel Layout Accessories &lt;/em&gt;dialog).&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGClamp&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGClamp&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Terminator&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForTerminator&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGROD&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGROD&amp;nbsp;&lt;/strong&gt;will be included in the parts available for selection in the &lt;strong&gt;Ground Rod&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog and will be available when using the &lt;strong&gt;Insert Rod Object&lt;/strong&gt; tool. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForGndRod&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWire&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGWire&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Wire type&lt;/strong&gt; field&amp;nbsp;on the &lt;em&gt;Place Grounding Grid dialog&lt;/em&gt;. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]]&lt;strong&gt; &amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWROD&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWROD&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Ground Rod connector&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWeldingGndRod&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWT&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWT&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 3-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 3-wire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWX&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWX&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 4-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 4-wire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;REP&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of &lt;strong&gt;REP&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Repeating&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;SGL&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;SGL&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Single&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;TER&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Beginning with version 08.11.12.120, devices assigned a part number that has a Part_Type value of &lt;strong&gt;TER&lt;/strong&gt; will be included when the &lt;strong&gt;Terminal/Plug &lt;/strong&gt;filter is applied on&amp;nbsp;&lt;em&gt;Insert Symbol By Device ID. &lt;/em&gt;Prior to this version, the software relied on the symbol type of the schematic symbol to determine if the device should appear under the &lt;strong&gt;Devices&lt;/strong&gt; or &lt;strong&gt;Terminal/Plug&lt;/strong&gt; filter.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;VAR&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;
&lt;p&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;VAR&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool.&lt;/p&gt;
&lt;p&gt;In SS7, parts with the &lt;strong&gt;VAR&lt;/strong&gt; part type were also available on &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; when the &amp;quot;Variable&amp;quot; filter was applied.&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;X-X&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;X-X&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Linear&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool. This value was not used prior to SS8. It is used in place of VAR which is now for cable and bus parts only.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style="margin-left:60px;"&gt;&lt;strong&gt;&amp;bull;&lt;/strong&gt; - indicates the Part_Type described in that row is used in the version indicated in that column.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[Part numbers missing from Insert Cable/Bus Object]]&lt;/p&gt;
&lt;p&gt;[[Parts missing from Insert Substation Objects]]&lt;/p&gt;
&lt;p&gt;[[Terminals, plugs missing from Insert Symbol By Device ID]]&lt;/p&gt;
&lt;p&gt;[[Parts Database Manager]]&lt;/p&gt;
&lt;p&gt;[[3D Layout Settings]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: parts database, 3D Layout Features, promis.e, Insert Cable_Bus Object, Insert Symbol By Part Number, Grounding Grid, Bentley Substation, en, Insert Substation Objects, Place Grounding Grid, Component Management, Component Features&lt;/div&gt;
</description></item><item><title>Part_Type filter values</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values/revision/4</link><pubDate>Wed, 07 Sep 2016 19:11:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:98ccc54e-005e-400f-9935-ac31433e1d12</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values#comments</comments><description>Revision 4 posted to OpenUtilities Wiki by Matt_P on 9/7/2016 7:11:28 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation, Promis.e&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.12.137 - 08.11.13.57&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Component Management&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Parts Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;This article provides a list of values that can be assigned to the &lt;strong&gt;Part_Type&lt;/strong&gt; field in part number records and the purpose of each value. &lt;strong&gt;Part_Type&lt;/strong&gt; values assigned to part numbers can be changed using [[Parts Database Manager]].&lt;/p&gt;
&lt;h1&gt;Part_Type values&lt;/h1&gt;
&lt;table border="2" cellpadding="1" cellspacing="2"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Part_Type&lt;/td&gt;
&lt;td&gt;SS8&lt;/td&gt;
&lt;td&gt;SS7&lt;/td&gt;
&lt;td&gt;Description&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGClamp&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGClamp&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Terminator&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForTerminator&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGROD&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGROD&amp;nbsp;&lt;/strong&gt;will be included in the parts available for selection in the &lt;strong&gt;Ground Rod&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog and will be available when using the &lt;strong&gt;Insert Rod Object&lt;/strong&gt; tool. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForGndRod&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWire&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGWire&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Wire type&lt;/strong&gt; field&amp;nbsp;on the &lt;em&gt;Place Grounding Grid dialog&lt;/em&gt;. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]]&lt;strong&gt; &amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWROD&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWROD&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Ground Rod connector&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWeldingGndRod&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWT&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWT&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 3-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 3-wire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWX&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWX&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 4-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 4-wire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;REP&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of &lt;strong&gt;REP&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Repeating&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;SGL&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;SGL&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Single&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;TER&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Beginning with version 08.11.12.120, devices assigned a part number that has a Part_Type value of &lt;strong&gt;TER&lt;/strong&gt; will be included when the &lt;strong&gt;Terminal/Plug &lt;/strong&gt;filter is applied on&amp;nbsp;&lt;em&gt;Insert Symbol By Device ID. &lt;/em&gt;Prior to this version, the software relied on the symbol type of the schematic symbol to determine if the device should appear under the &lt;strong&gt;Devices&lt;/strong&gt; or &lt;strong&gt;Terminal/Plug&lt;/strong&gt; filter.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;VAR&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;
&lt;p&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;VAR&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool.&lt;/p&gt;
&lt;p&gt;In SS7, parts with the &lt;strong&gt;VAR&lt;/strong&gt; part type were also available on &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; when the &amp;quot;Variable&amp;quot; filter was applied.&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;X-X&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;X-X&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Linear&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style="margin-left:60px;"&gt;&lt;strong&gt;&amp;bull;&lt;/strong&gt; - indicates the Part_Type described in that row is used in the version indicated in that column.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[Part numbers missing from Insert Cable/Bus Object]]&lt;/p&gt;
&lt;p&gt;[[Parts missing from Insert Substation Objects]]&lt;/p&gt;
&lt;p&gt;[[Terminals, plugs missing from Insert Symbol By Device ID]]&lt;/p&gt;
&lt;p&gt;[[Parts Database Manager]]&lt;/p&gt;
&lt;p&gt;[[3D Layout Settings]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: parts database, Grounding Grid, Bentley Substation, en, SELECTsupport, Component Management&lt;/div&gt;
</description></item><item><title>Part_Type filter values</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values/revision/3</link><pubDate>Fri, 15 Jul 2016 15:28:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:98ccc54e-005e-400f-9935-ac31433e1d12</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values#comments</comments><description>Revision 3 posted to OpenUtilities Wiki by Matt_P on 7/15/2016 3:28:15 PM&lt;br /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.12.137 - 08.11.13.52&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Component Management&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Parts Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;This article provides a list of values that can be assigned to the &lt;strong&gt;Part_Type&lt;/strong&gt; field in part number records and the purpose of each value. &lt;strong&gt;Part_Type&lt;/strong&gt; values assigned to part numbers can be changed using [[Parts Database Manager]].&lt;/p&gt;
&lt;h1&gt;Part_Type values&lt;/h1&gt;
&lt;table cellpadding="1" cellspacing="2" border="2"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Part_Type&lt;/td&gt;
&lt;td&gt;SS8&lt;/td&gt;
&lt;td&gt;SS7&lt;/td&gt;
&lt;td&gt;Description&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGClamp&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGWT&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Terminator&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForTerminator&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGROD&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGROD&amp;nbsp;&lt;/strong&gt;will be included in the parts available for selection in the &lt;strong&gt;Ground Rod&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog and will be available when using the &lt;strong&gt;Insert Rod Object&lt;/strong&gt; tool. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForGndRod&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWire&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGWire&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Wire type&lt;/strong&gt; field&amp;nbsp;on the &lt;em&gt;Place Grounding Grid dialog&lt;/em&gt;. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]]&lt;strong&gt; &amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWROD&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWROD&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Ground Rod connector&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWeldingGndRod&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWT&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWT&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 3-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 3-wire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWX&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWX&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 4-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 4-wire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;REP&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of &lt;strong&gt;REP&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Repeating&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;SGL&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;SGL&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Single&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;TER&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Beginning with version 08.11.12.120, devices assigned a part number that has a Part_Type value of &lt;strong&gt;TER&lt;/strong&gt; will be included when the &lt;strong&gt;Terminal/Plug &lt;/strong&gt;filter is applied on&amp;nbsp;&lt;em&gt;Insert Symbol By Device ID. &lt;/em&gt;Prior to this version, the software relied on the symbol type of the schematic symbol to determine if the device should appear under the &lt;strong&gt;Devices&lt;/strong&gt; or &lt;strong&gt;Terminal/Plug&lt;/strong&gt; filter.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;VAR&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;
&lt;p&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;VAR&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool.&lt;/p&gt;
&lt;p&gt;In SS7, parts with the &lt;strong&gt;VAR&lt;/strong&gt; part type were also available on &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; when the &amp;quot;Variable&amp;quot; filter was applied.&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;X-X&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;X-X&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Linear&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style="margin-left:60px;"&gt;&lt;strong&gt;&amp;bull;&lt;/strong&gt; - indicates the Part_Type described in that row is used in the version indicated in that column.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[Part numbers missing from Insert Cable/Bus Object]]&lt;/p&gt;
&lt;p&gt;[[Parts missing from Insert Substation Objects]]&lt;/p&gt;
&lt;p&gt;[[Terminals, plugs missing from Insert Symbol By Device ID]]&lt;/p&gt;
&lt;p&gt;[[Parts Database Manager]]&lt;/p&gt;
&lt;p&gt;[[3D Layout Settings]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" height="60" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: parts database, Grounding Grid, Bentley Substation, en, SELECTsupport, Component Management&lt;/div&gt;
</description></item><item><title>Part_Type filter values</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values/revision/2</link><pubDate>Fri, 15 Jul 2016 15:26:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:98ccc54e-005e-400f-9935-ac31433e1d12</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values#comments</comments><description>Revision 2 posted to OpenUtilities Wiki by Matt_P on 7/15/2016 3:26:35 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.12.137 - 08.11.13.52&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Component Management&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Parts Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;This article provides a list of values that can be assigned to the &lt;strong&gt;Part_Type&lt;/strong&gt; field in part number records and the purpose of each value. &lt;strong&gt;Part_Type&lt;/strong&gt; values assigned to part numbers can be changed using [[Parts Database Manager]].&lt;/p&gt;
&lt;h1&gt;Part_Type values&lt;/h1&gt;
&lt;table style="width:75%;" cellpadding="1" cellspacing="2" border="2"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Part_Type&lt;/td&gt;
&lt;td&gt;SS8&lt;/td&gt;
&lt;td&gt;SS7&lt;/td&gt;
&lt;td&gt;Description&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGClamp&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGWT&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Terminator&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForTerminator&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGROD&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGROD&amp;nbsp;&lt;/strong&gt;will be included in the parts available for selection in the &lt;strong&gt;Ground Rod&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog and will be available when using the &lt;strong&gt;Insert Rod Object&lt;/strong&gt; tool. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForGndRod&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWire&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGWire&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Wire type&lt;/strong&gt; field&amp;nbsp;on the &lt;em&gt;Place Grounding Grid dialog&lt;/em&gt;. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]]&lt;strong&gt; &amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWROD&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWROD&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Ground Rod connector&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWeldingGndRod&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWT&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWT&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 3-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 3-wire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWX&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWX&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 4-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 4-wire&lt;/strong&gt;.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;REP&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of &lt;strong&gt;REP&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Repeating&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;SGL&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;SGL&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Single&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;TER&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;Beginning with version 08.11.12.120, devices assigned a part number that has a Part_Type value of &lt;strong&gt;TER&lt;/strong&gt; will be included when the &lt;strong&gt;Terminal/Plug &lt;/strong&gt;filter is applied on&amp;nbsp;&lt;em&gt;Insert Symbol By Device ID. &lt;/em&gt;Prior to this version, the software relied on the symbol type of the schematic symbol to determine if the device should appear under the &lt;strong&gt;Devices&lt;/strong&gt; or &lt;strong&gt;Terminal/Plug&lt;/strong&gt; filter.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;VAR&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td&gt;
&lt;p&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;VAR&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool.&lt;/p&gt;
&lt;p&gt;In SS7, parts with the &lt;strong&gt;VAR&lt;/strong&gt; part type were also available on &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; when the &amp;quot;Variable&amp;quot; filter was applied.&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;X-X&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&amp;bull;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;X-X&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Linear&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style="margin-left:60px;"&gt;&lt;strong&gt;&amp;bull;&lt;/strong&gt; - indicates the Part_Type described in that row is used in the version indicated in that column.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[Part numbers missing from Insert Cable/Bus Object]]&lt;/p&gt;
&lt;p&gt;[[Parts missing from Insert Substation Objects]]&lt;/p&gt;
&lt;p&gt;[[Terminals, plugs missing from Insert Symbol By Device ID]]&lt;/p&gt;
&lt;p&gt;[[Parts Database Manager]]&lt;/p&gt;
&lt;p&gt;[[3D Layout Settings]]&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" height="60" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: parts database, Grounding Grid, Bentley Substation, en, SELECTsupport, Component Management&lt;/div&gt;
</description></item><item><title>Part_Type filter values</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values/revision/1</link><pubDate>Thu, 14 Jul 2016 21:53:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:98ccc54e-005e-400f-9935-ac31433e1d12</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/29886/part_5f00_type-filter-values#comments</comments><description>Revision 1 posted to OpenUtilities Wiki by Matt_P on 7/14/2016 9:53:28 PM&lt;br /&gt;
&lt;table style="border-top:#dce5f0 0px solid;border-right:#dce5f0 0px solid;border-bottom:#dce5f0 0px solid;border-left:#dce5f0 0px solid;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.12.137 - 08.11.13.52&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Component Management&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Parts Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;This article provides a list of values that can be assigned to the &lt;strong&gt;Part_Type&lt;/strong&gt; field in part number records and the purpose of each value. &lt;strong&gt;Part_Type&lt;/strong&gt; values assigned to part numbers can be changed using [[Parts Database Manager]].&lt;/p&gt;
&lt;h1&gt;Part_Type values&lt;/h1&gt;
&lt;p&gt;
&lt;table cellspacing="2" cellpadding="1" width="75%" border="2"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Part_Type&lt;/td&gt;
&lt;td&gt;SS8&lt;/td&gt;
&lt;td&gt;SS7&lt;/td&gt;
&lt;td&gt;Description&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGClamp&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGWT&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Terminator&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForTerminator&lt;/strong&gt;.&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGROD&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGROD&amp;nbsp;&lt;/strong&gt;will be included in the parts available for selection in the &lt;strong&gt;Ground Rod&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog and will be available when using the &lt;strong&gt;Insert Rod Object&lt;/strong&gt; tool. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForGndRod&lt;/strong&gt;.&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWire&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;GGWire&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Wire type&lt;/strong&gt; field&amp;nbsp;on the &lt;em&gt;Place Grounding Grid dialog&lt;/em&gt;. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]]&lt;strong&gt; &amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWire&lt;/strong&gt;.&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWROD&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWROD&lt;/strong&gt;  will be included in the parts available for selection in the &lt;strong&gt;Ground Rod connector&lt;/strong&gt;&amp;nbsp;field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; PartTypeForWeldingGndRod&lt;/strong&gt;.&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWT&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWT&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 3-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 3-wire&lt;/strong&gt;.&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;GGWX&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;By default, parts with a Part_Type value of &lt;strong&gt;GGWX&lt;/strong&gt;&amp;nbsp;will be included in the parts available for selection in the &lt;strong&gt;Connector 4-wire&lt;/strong&gt; field on the &lt;em&gt;Place Grounding Grid&lt;/em&gt; dialog. To have the software filter on a different Part_Type value, specify the value in [[3D Layout Settings]] &lt;strong&gt;&amp;gt; Project Settings &amp;gt; Grounding Grid &amp;gt; Connector 4-wire&lt;/strong&gt;.&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;REP&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of &lt;strong&gt;REP&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Repeating&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;SGL&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;SGL&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Single&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;TER&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;VAR&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;
&lt;p&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;VAR&lt;/strong&gt; will be included in the parts available for selection in the &lt;strong&gt;Insert Cable/Bus Object&lt;/strong&gt; tool. &lt;/p&gt;
&lt;p&gt;In SS7, parts with the &lt;strong&gt;VAR&lt;/strong&gt; part type were also available on &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; when the &amp;quot;Variable&amp;quot; filter was applied.&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;X-X&lt;/td&gt;
&lt;td&gt;•&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;Parts with a Part_Type value of&amp;nbsp;&lt;strong&gt;X-X&lt;/strong&gt; will be included in the parts available for selection when the &amp;quot;Linear&amp;quot; &lt;strong&gt;Substation Filter&lt;/strong&gt; is applied when using the &lt;strong&gt;Insert Substation Objects&lt;/strong&gt; tool.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[Part numbers missing from Insert Cable/Bus Object]]&lt;/p&gt;
&lt;p&gt;[[Parts missing from Insert Substation Objects]]&lt;/p&gt;
&lt;p&gt;[[Terminals, plugs missing from Insert Symbol By Device ID]]&lt;/p&gt;
&lt;p&gt;[[Parts Database Manager]]&lt;/p&gt;
&lt;p&gt;[[3D Layout Settings]]&lt;/p&gt;&lt;img style="border-left-width:0px;border-right-width:0px;border-bottom-width:0px;border-top-width:0px;" alt=" " src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" /&gt; 
&lt;table style="border-top:#dce5f0 0px solid;border-right:#dce5f0 0px solid;border-bottom:#dce5f0 0px solid;border-left:#dce5f0 0px solid;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: parts database, Grounding Grid, Bentley Substation, en, SELECTsupport, Component Management&lt;/div&gt;