Configuration Variables - Bentley Substation v10.00-10.02


Product(s):Bentley Substation CONNECT Edition
Version(s):10.00 - 10.02
Environment:N/A
Area:Installation_Configuration
Subarea:N/A

Overview

In the CONNECT Edition, the software utilizes the native Power Platform configuration system to locate the dataset, connect to the project database, and specify various default settings.

Note: Power Platform is the MicroStation core application that underlies the CONNECT Edition product.

New configuration variables have been introduced that can be set in any configuration file to configure the software. The purpose of this article is to provide a comprehensive list of the application specific variables that are used to configure the software and explain their purpose.

Substation Configuration Variables

Application variables are prefixed with “ELEC_” to set them apart from the standard Power Platform variables.

The following table provides a complete list of the application specific variables and defines what if any dialog boxes within the software can set their values:

Variable Name

Description

Dialogs that Control the Variable

ELEC_DRAWING_STANDARD

Drawing standard (IEC vs ANSI-IEEE)

 

- Installer

ELEC_WORKSETSTANDARDS

Substation WorkSet standards folder

-           

ELEC_WORKSETDGNS

Location where DGN files will be stored

-           

ELEC_DATABASE_SERVER

Project database SQL server name

- Installer

- New Project

ELEC_PRJ_DB_CONNECTIONSTRING

Project database connection string

- New Project

- WorkSpace Configuration Variables

ELEC_PRJ_DB_NAME

Project database name

 

- New / Modify Project

- WorkSpace Configuration Variables

ELEC_PRJ_DB_PER_PROJECT

Separate database per project setting

- New Project

- WorkSpace Configuration Variables

ELEC_ACTIVEPARTSDATABASE

Active parts database name

- New / Modify Project

- WorkSpace Configuration Variables

ELEC_PARTS_DB_MAPPING_PATH

Path to the parts database mapping file which defines the connection to the parts database

- WorkSpace Configuration Variables

 

ELEC_CATALOG_PATH

Path to catalogs

- New / Modify Project

- WorkSpace Configuration Variables

ELEC_LANGUAGE_DB_PATH

Path to the Multi-language.mdb file

-           

ELEC_SYSTEM_OPTION_PROFILE

Path to the system option profile XML file

- WorkSpace Configuration Variables

ELEC_PROJECT_OPTION_PROFILE

Path to the project option profile XML file

- WorkSpace Configuration Variables

ELEC_USER_OPTION_PROFILE

Path to the user option profile XML file

- WorkSpace Configuration Variables

ELEC_PRJ_PROFILE_DIR

Path to the project profiles

- WorkSpace Configuration Variables

ELEC_PAGE_FORMAT_DIR

Path to the page formats

- WorkSpace Configuration Variables

ELEC_TEMPLATES_GRAPHICPLAN_DIR

Path to the graphical plan templates folder

- WorkSpace Configuration Variables

ELEC_TEMPLATES_PAGE_DIR

Path to the page templates folder

- WorkSpace Configuration Variables

ELEC_TEMPLATES_REPORT_DIR

Path to the report templates folder

- WorkSpace Configuration Variables

ELEC_SHOW_PWCHECKIN_DIALOG

Specifies whether the ProjectWise Check In dialog should be displayed when a file is closed or if the file should be automatically checked it in.

-           

These configuration variables can be set in any configuration file. To understand how these variables are used in the configuration files that are delivered with a default installation of the software, please refer to the Configuration Files article.