<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>How to Disable ProjectWise Desktop Integration with Substation CONNECT</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/40467/how-to-disable-projectwise-desktop-integration-with-substation-connect</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to Disable ProjectWise Desktop Integration with Substation CONNECT</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/40467/how-to-disable-projectwise-desktop-integration-with-substation-connect</link><pubDate>Fri, 23 Jul 2021 06:22:36 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:82e154f9-31fa-47e0-aede-6147ec089699</guid><dc:creator>Satish Saptasagar</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/40467/how-to-disable-projectwise-desktop-integration-with-substation-connect#comments</comments><description>Current Revision posted to OpenUtilities Wiki by Satish Saptasagar on 7/23/2021 6:22:36 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenUtilities Substation CONNECT&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="background-color:transparent;color:#000000;float:none;font-family:Verdana,Arial,Helvetica,sans-serif;font-size:11px;font-style:normal;font-weight:400;letter-spacing:normal;text-align:left;text-decoration:none;text-indent:0px;text-transform:none;white-space:normal;"&gt;10.00.XX.XX to 10.10.XX.XX&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ProjectWise&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;When Substation CONNECT is launched, below dialog appears which prompts to connect to ProjectWise Datasource. It can take a while before the software search for available datasources. This increases the time required to open the software and start working with it. Also, some users may not be integrated in a ProjectWise environment and may be working locally. For them this dialog is redundant.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-62/8625.pw1.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;Steps given below would allow users to disable this dialog to appear while start up.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Change ProjectWise Installation:&amp;nbsp;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/span&gt;1. Go to Control Panel &amp;gt; Program and Features and select ProjectWise Explorer&lt;br /&gt;&lt;br /&gt;2. Right click and select Change from the context menu&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-62/6153.pw3.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;3. Click Next on the subsequent dialog and get to the below dialog.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/700x400/__key/communityserver-wikis-components-files/00-00-00-00-62/3857.pw4.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;4. Expand ProjectWise Explorer and Tools and then uncheck iDesktop Integration&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/700x400/__key/communityserver-wikis-components-files/00-00-00-00-62/7103.pw5.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;5. Then click Modify to apply the changes made&lt;br /&gt;&lt;br /&gt;Note: This change will be applicable to all applications that use ProjectWise Integration on the machine&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Without Changing ProjectWise Installation:&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;If you do not want to change the ProjectWise installation and still want to disable desktop integration with ProjectWise then:&lt;br /&gt;&lt;br /&gt;1. Go to &lt;strong&gt;C:\Program Files\Bentley\OpenUtilities Substation CONNECT Edition\Substation\config\appl&lt;/strong&gt;.&lt;br /&gt;&lt;br /&gt;2. Open &lt;strong&gt;pw.cfg&lt;/strong&gt; file in Notepad&lt;br /&gt;&lt;br /&gt;3. Remove the &amp;#39;#&amp;#39; sign before the highlighted variable and save it&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/600x240/__key/communityserver-wikis-components-files/00-00-00-00-62/5611.pw6.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sarvesh Kulkarni&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, ProjectWise, disable, substation, integration, Bentley Substation, en, ProjectWise integration&lt;/div&gt;
</description></item><item><title>How to Disable ProjectWise Desktop Integration with Substation CONNECT</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/40467/how-to-disable-projectwise-desktop-integration-with-substation-connect/revision/1</link><pubDate>Wed, 12 Dec 2018 19:32:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:82e154f9-31fa-47e0-aede-6147ec089699</guid><dc:creator>Sarvesh Kulkarni</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/40467/how-to-disable-projectwise-desktop-integration-with-substation-connect#comments</comments><description>Revision 1 posted to OpenUtilities Wiki by Sarvesh Kulkarni on 12/12/2018 7:32:48 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Substation CONNECT&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="background-color:transparent;color:#000000;float:none;font-family:Verdana,Arial,Helvetica,sans-serif;font-size:11px;font-style:normal;font-weight:400;letter-spacing:normal;text-align:left;text-decoration:none;text-indent:0px;text-transform:none;white-space:normal;"&gt;through 10.02.00.31&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ProjectWise&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;When Substation CONNECT is launched, below dialog appears which prompts to connect to ProjectWise Datasource. It can take a while before the software search for available datasources. This increases the time required to open the software and start working with it. Also, some users may not be integrated in a ProjectWise environment and may be working locally. For them this dialog is redundant.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-26/8625.pw1.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;Steps given below would allow users to disable this dialog to appear while start up.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Change ProjectWise Installation:&amp;nbsp;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/span&gt;1. Go to Control Panel &amp;gt; Program and Features and select ProjectWise Explorer&lt;br /&gt;&lt;br /&gt;2. Right click and select Change from the context menu&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-26/6153.pw3.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;3. Click Next on the subsequent dialog and get to the below dialog.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/700x400/__key/communityserver-wikis-components-files/00-00-00-00-26/3857.pw4.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;4. Expand ProjectWise Explorer and Tools and then uncheck iDesktop Integration&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/700x400/__key/communityserver-wikis-components-files/00-00-00-00-26/7103.pw5.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;5. Then click Modify to apply the changes made&lt;br /&gt;&lt;br /&gt;Note: This change will be applicable to all applications that use ProjectWise Integration on the machine&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Without Changing ProjectWise Installation:&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;If you do not want to change the ProjectWise installation and still want to disable desktop integration with ProjectWise then:&lt;br /&gt;&lt;br /&gt;1. Go to &lt;strong&gt;C:\Program Files\Bentley\Bentley Substation CONNECT Edition\Substation\config\appl&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;2. Open &lt;strong&gt;pw.cfg&lt;/strong&gt; file in Notepad&lt;br /&gt;&lt;br /&gt;3. Remove the &amp;#39;#&amp;#39; sign before the highlighted variable and save it&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/600x240/__key/communityserver-wikis-components-files/00-00-00-00-26/5611.pw6.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sarvesh Kulkarni&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, ProjectWise, disable, substation, integration, Bentley Substation, en, ProjectWise integration&lt;/div&gt;
</description></item><item><title>How to Disable ProjectWise Desktop Integration with Substation CONNECT</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/40467/how-to-disable-projectwise-desktop-integration-with-substation-connect/revision/2</link><pubDate>Wed, 12 Dec 2018 19:32:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:82e154f9-31fa-47e0-aede-6147ec089699</guid><dc:creator>Sarvesh Kulkarni</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/40467/how-to-disable-projectwise-desktop-integration-with-substation-connect#comments</comments><description>Revision 2 posted to OpenUtilities Wiki by Sarvesh Kulkarni on 12/12/2018 7:32:48 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Substation CONNECT&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="background-color:transparent;color:#000000;float:none;font-family:Verdana,Arial,Helvetica,sans-serif;font-size:11px;font-style:normal;font-weight:400;letter-spacing:normal;text-align:left;text-decoration:none;text-indent:0px;text-transform:none;white-space:normal;"&gt;through 10.02.00.31&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;ProjectWise&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;When Substation CONNECT is launched, below dialog appears which prompts to connect to ProjectWise Datasource. It can take a while before the software search for available datasources. This increases the time required to open the software and start working with it. Also, some users may not be integrated in a ProjectWise environment and may be working locally. For them this dialog is redundant.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-62/8625.pw1.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;Steps given below would allow users to disable this dialog to appear while start up.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Change ProjectWise Installation:&amp;nbsp;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/span&gt;1. Go to Control Panel &amp;gt; Program and Features and select ProjectWise Explorer&lt;br /&gt;&lt;br /&gt;2. Right click and select Change from the context menu&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-62/6153.pw3.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;3. Click Next on the subsequent dialog and get to the below dialog.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/700x400/__key/communityserver-wikis-components-files/00-00-00-00-62/3857.pw4.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;4. Expand ProjectWise Explorer and Tools and then uncheck iDesktop Integration&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/700x400/__key/communityserver-wikis-components-files/00-00-00-00-62/7103.pw5.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;5. Then click Modify to apply the changes made&lt;br /&gt;&lt;br /&gt;Note: This change will be applicable to all applications that use ProjectWise Integration on the machine&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Without Changing ProjectWise Installation:&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;If you do not want to change the ProjectWise installation and still want to disable desktop integration with ProjectWise then:&lt;br /&gt;&lt;br /&gt;1. Go to &lt;strong&gt;C:\Program Files\Bentley\Bentley Substation CONNECT Edition\Substation\config\appl&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;2. Open &lt;strong&gt;pw.cfg&lt;/strong&gt; file in Notepad&lt;br /&gt;&lt;br /&gt;3. Remove the &amp;#39;#&amp;#39; sign before the highlighted variable and save it&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/600x240/__key/communityserver-wikis-components-files/00-00-00-00-62/5611.pw6.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Sarvesh Kulkarni&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, ProjectWise, disable, substation, integration, Bentley Substation, en, ProjectWise integration&lt;/div&gt;