Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenUtilities
  • Product Communities
OpenUtilities
OpenUtilities Wiki Configuration Variables - Promis.e
    • Sign In
    • +OpenUtilities
    • Access Service Request Manager
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities sisNET - English
    • +OpenUtilities Substation
    • Promis.e Paths
    • -Promis.e Wiki
      • -CONNECT Edition - Promis.e
        • +Administration Features - Promis.e CONNECT
        • +Automation Features - Promis.e CONNECT
        • +Component Features - Promis.e CONNECT
        • +Component Management - Promis.e CONNECT
        • +Database Platform Support - Promis.e CONNECT
        • +Drawing Management - Promis.e Connect
        • -Installation_Configuration - Promis.e CONNECT Edition
          • Application Data (per-user configuration) - Promis.e CONNECT
          • +Compatibility Chart - Promis.e CONNECT Edition
          • Configuration Files - Promis.e
          • Configuration Variables - Promis.e
          • Deployment Guide - Promis.e CONNECT Edition
          • How to Configure WorkSpace & WorkSet on Network Location for Promis.e CONNECT
          • How to create App Data Folder Deployment in Promis.e Connect
          • How to create Deployment Image-Promis.e CONNECT
          • How to Deploy Custom Parts Database Manager layout
          • How to do clean installation- Promis.e CONNECT
          • How to Download Promis.e CONNECT - Promis.e CONNECT
          • How to install Promis.e CONNECT
          • How to Silent Install Promis.e CONNECT
          • +Installation Errors - Installation_Configuration - Promis.e CONNECT Edition
          • Migrating Promis.e from V8i to CONNECT Edition
          • Program Folder - Promise CONNECT
          • Promis.e CONNECT Edition System Requirements
          • Seed files not correct after restoring project in Promis.e CONNECT
          • To change Dialog Layout Configuration location to Registry files from per user App Data folder
          • +WorkSpace & WorkSet - Promis.e CONNECT Edition
        • +Maintenance Features - Promis.e CONNECT
        • +Migration - Promis.e CONNECT
        • +OS & Hardware Support - Promis.e CONNECT
        • +Panel Layout Mode - Promis.e CONNECT
        • +Power Platform Support - Promis.e CONNECT
        • +Print and Plot features Promis.e CONNECT
        • +Project Management - Promis.e CONNECT
        • +ProjectWise Integration - Promis.e CONNECT
        • +Reports_Output Features - Promis.e CONNECT
        • +Resolved issues in Promis.e Releases
        • +Wire Numbering - Promis.e CONNECT
        • +Wiring Feature - Promis.e CONNECT
      • About Promis.e
      • +Administration Features - Promis.e
      • +APIs_VBA - Promis.e
      • +Automation Features - Promis.e
      • +Component Features - Promis.e
      • +Component Management - Promis.e
      • +CONNECT Services - Promis.e
      • +Data Manager - Promis.e
      • +Database Platform Support - Promis.e
      • +Display - Promis.e
      • +Drawing Management - Promis.e
      • +Engineering Design Considerations - Promis.e
      • Error - Object reference...General
      • +Find_Replace - Promis.e
      • Finding the Tutorial
      • +Installation_Configuration - Promis.e
      • +Interoperability - Promis.e
      • +Licensing - Promis.e
      • +Maintenance Features - Promis.e
      • +Migration - Promis.e
      • +OS Support - Promis.e
      • +Panel Layout - Promis.e
      • +Performance - Promis.e
      • +PowerPlatform Support - Promis.e
      • +Print_Publish Features - Promis.e
      • +ProjectWise Integration - Promis.e
      • Promis.e Help file
      • +Reports_Output Features - Promis.e
      • +Template Management - Promis.e
      • +Text Tools - Promis.e
      • Training FAQs
      • +Wire Numbering - Promis.e
      • +Wiring Features - Promis.e
      • +Project Management - Promis.e
      • Promis.e Title
      • Working from home with Promise.e
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    Configuration Variables - Promis.e

    Product(s): Promis.e CONNECT Edition
    Version(s): 10
    Environment: N/A
    Area: Installation_Configuration
    Subarea: N/A

    In the CONNECT Edition, the software utilizes the native Power Platform configuration system to locate the dataset, connect to the project database, and specify various default settings.

    Note: Power Platform is the MicroStation core application that underlies the CONNECT Edition product.

    New configuration variables have been introduced that can be set in any configuration file to configure the software. The purpose of this article is to provide a comprehensive list of the application specific variables that are used to configure the software and explain their purpose.

    Promis.e Configuration Variables

    Application variables are prefixed with “ELEC_” to set them apart from the standard Power Platform variables.

    The following table provides a complete list of the application specific variables and defines what if any dialog boxes within the software can set their values:

    Variable Name

    Description

    Dialogs that Control the Variable

    ELEC_DRAWING_STANDARD

    Drawing standard (IEC vs ANSI-IEEE)

     

    -

    ELEC_WORKSETSTANDARDS

    Promis.e WorkSet standards folder

    -           

    ELEC_WORKSETDGNS

    Location where DGN files will be stored

    -           

    ELEC_DEFAULT_PROJECT_DIR

    The default folder that the Project Manager sets focus to

    - Configuration Variables

    ELEC_ACTIVEPARTSDATABASE

    Active parts database name

    - Configuration Variables

    ELEC_PARTS_DB_MAPPING_PATH

    Path to the parts database mapping file which defines the connection to the parts database

    - Configuration Variables

    ELEC_CATALOG_PATH

    All catalogs found in the path specified will be loaded. Users can specify multiple paths delimited by a semi-colon if they want to load catalogs from multiple locations (i.e. some catalogs on the local machine and some on a network share)

    - Configuration Variables

    ELEC_LANGUAGE_DB_PATH

    Path to the Multi-language.mdb file

    -           

    ELEC_SYSTEM_OPTION_PROFILE

    Path to the system option profile XML file

    - Configuration Variables

    ELEC_PROJECT_OPTION_PROFILE

    Path to the project option profile XML file

    - Configuration Variables

    ELEC_USER_OPTION_PROFILE

    Path to the user option profile XML file

    - Configuration Variables

    ELEC_PRJ_PROFILE_DIR

    Path to the project profiles

    - Configuration Variables

    ELEC_PAGE_FORMAT_DIR

    Path to the page formats

    - Configuration Variables

    ELEC_TEMPLATES_GRAPHICPLAN_DIR

    Path to the graphical plan templates folder

    - Configuration Variables

    ELEC_TEMPLATES_PAGE_DIR

    Path to the page templates folder

    - Configuration Variables

    ELEC_TEMPLATES_REPORT_DIR

    Path to the report templates folder

    - Configuration Variables

    ELEC_ENABLE_MANAGED_CONFIGURATION

    True/False variable that enables or disables the ProjectWise Managed Workspace integration

    Refer to the Managed WorkSpace Configuration guide for instructions on how to configure a managed WorkSpace which makes use of additional variables not discussed here.

    ELEC_SHOW_PWCHECKIN_DIALOG

    Specifies whether the ProjectWise Check In dialog should be displayed when a file is closed or if the file should be automatically checked it in.

    -           

    These configuration variables can be set in any configuration file. To understand how these variables are used in the configuration files that are delivered with a default installation of the software, please refer to the Configuration Files article.

    • CONNECT Edition
    • Administration
    • Proims.e
    • en
    • Installation_Configuration
    • Promis.e CONNECT Edition
    • Share
    • History
    • More
    • Cancel
    • Scott Walker Created by Bentley Colleague Scott Walker
    • When: Tue, Mar 5 2019 11:18 AM
    • Jesse Dringoli Last revision by Bentley Colleague Communities MVP Jesse Dringoli
    • When: Fri, Mar 27 2020 2:31 PM
    • Revisions: 5
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies