Configuration Variables - Bentley Substation v10.03+


Product(s):Bentley Substation CONNECT Edition
Version(s):10.03+
Environment:N/A
Area:Installation_Configuration
Subarea:N/A

In the CONNECT Edition, the software utilizes the native Power Platform configuration system to locate the dataset, connect to the project database, and specify various default settings.

Note: Power Platform is the MicroStation core application that underlies the CONNECT Edition product.

New configuration variables have been introduced that can be set in any configuration file to configure the software. The purpose of this article is to provide a comprehensive list of the application specific variables that are used to configure the software and explain their purpose.

Bentley Substation Configuration Variables

Application variables are prefixed with “ELEC_” to set them apart from the standard Power Platform variables.

The following table provides a complete list of the application specific variables and defines what if any dialog boxes within the software can set their values:

Variable Name

Description

Dialogs that Control the Variable

ELEC_DRAWING_STANDARD

Drawing standard (IEC vs ANSI-IEEE)

 

-

ELEC_WORKSETSTANDARDS

Substation WorkSet standards folder

-           

ELEC_WORKSETDGNS

Location where DGN files will be stored

-           

ELEC_DEFAULT_PROJECT_DIR

The default folder that the Project Manager sets focus to

- Configuration Variables

ELEC_ACTIVEPARTSDATABASE

Active parts database name

- Configuration Variables

ELEC_PARTS_DB_MAPPING_PATH

Path to the parts database mapping file which defines the connection to the parts database

- Configuration Variables

ELEC_CATALOG_PATH

All catalogs found in the path specified will be loaded. Users can specify multiple paths delimited by a semi-colon if they want to load catalogs from multiple locations (i.e. some catalogs on the local machine and some on a network share)

- Configuration Variables

ELEC_LANGUAGE_DB_PATH

Path to the Multi-language.mdb file

-           

ELEC_SYSTEM_OPTION_PROFILE

Path to the system option profile XML file

- Configuration Variables

ELEC_PROJECT_OPTION_PROFILE

Path to the project option profile XML file

- Configuration Variables

ELEC_USER_OPTION_PROFILE

Path to the user option profile XML file

- Configuration Variables

ELEC_PRJ_PROFILE_DIR

Path to the project profiles

- Configuration Variables

ELEC_PAGE_FORMAT_DIR

Path to the page formats

- Configuration Variables

ELEC_TEMPLATES_GRAPHICPLAN_DIR

Path to the graphical plan templates folder

- Configuration Variables

ELEC_TEMPLATES_PAGE_DIR

Path to the page templates folder

- Configuration Variables

ELEC_TEMPLATES_REPORT_DIR

Path to the report templates folder

- Configuration Variables

ELEC_ENABLE_MANAGED_CONFIGURATION

True/False variable that enables or disables the ProjectWise Managed Workspace integration

Refer to the Managed WorkSpace Configuration guide for instructions on how to configure a managed WorkSpace which makes use of additional variables not discussed here.

ELEC_SHOW_PWCHECKIN_DIALOG

Specifies whether the ProjectWise Check In dialog should be displayed when a file is closed or if the file should be automatically checked it in.

-           

These configuration variables can be set in any configuration file. To understand how these variables are used in the configuration files that are delivered with a default installation of the software, please refer to the Configuration Files article.