OpenUtilities Wiki Configuration Files - Bentley Substation v10.03+
    • Sign in
    • +OpenUtilities
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • -OpenUtilities Substation
      • -CONNECT Edition - OpenUtilities Substation
        • +3D Layout Features - OpenUtilities-Substation
        • +Administration Features - OpenUtilities Substation
        • +Automation Feature
        • +Components Features - Substation CONNECT
        • +Database Platform Support
        • -Installation_Configuration - Bentley Substation CONNECT Edition
          • Compatibility Chart - OpenUtilities Substation CONNECT
          • Configuration Files - Bentley Substation v10.00-10.02
          • Configuration Files - Bentley Substation v10.03+
          • Configuration Variables - Bentley Substation v10.00-10.02
          • Configuration Variables - Bentley Substation v10.03+
          • Deployment Guide - Bentley Substation CONNECT Edition v10.03+
          • Deployment Guide - Substation CONNECT Edition v10.00-10.02
          • How to Clean Install OpenUtilities Substation
          • How to create Deployment Image for OpenUtilities Substation CONNECT Edition
          • How to Deploy Custom Parts Database Manager layout - OpenUtilities Substation
          • +How to download the Bentley Substation software
          • How to Silent Install OpenUtilities Substation
          • +Installation Errors - Installation_Configuration - OpenUtilities Substation CONNECT Edition
          • Migrating Bentley Substation from V8i to CONNECT Edition - Bentley Substation v10.00-10.02
          • Migrating Bentley Substation from V8i to CONNECT Edition v10.03+
          • OpenUtilities Substation CONNECT Edition System Requirements
          • Program Data / Configuration Folder
          • Program Folder - OpenUtilities Substation CONNECT
          • Working with Template WorkSets - Bentley Substation v10.00-10.02
          • Working with Template WorkSets - Bentley Substation v10.03+
        • +OS & Hardware Support - OpenUtilities Substation CONNECT
        • +Power Platform Support - Substation CONNECT
        • +Project Management - OpenUtilities Substation CE
        • +Resolved issues in OpenUtilities Substation Releases
        • +Wire Numbering - Substation CONNECT
      • +3D Layout Features - Bentley Substation
      • About Bentley Substation
      • +Administration Features - Bentley Substation
      • +Automation Features - Bentley Substation
      • +Component Management - Bentley Substation
      • +Construction Drawings - Bentley Substation
      • +Database Platform Support - Bentley Substation
      • +Grounding Grid - Bentley Substation
      • How to log Service Request
      • +Installation_Configuration - Bentley Substation
      • +Interoperability - Bentley Substation
      • +PowerPlatform Support - Bentley Substation
      • +Project Management - Bentley Substation
      • +ProjectWise Integration - Bentley Substation
      • Working from home with OpenUtilities Substation
    • Promis.e Paths
    • +Promis.e Wiki
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    Configuration Files - Bentley Substation v10.03+

    Product(s): Bentley Substation CONNECT Edition
    Version(s): 10.03+
    Environment: N/A
    Area: Installation_Configuration

    Subarea:

    N/A

    In the CONNECT Edition, the software utilizes the native Power Platform configuration system to locate the dataset, connect to the project database, and specify various default settings.

    Note: Power Platform is the MicroStation core application that underlies the CONNECT Edition product.

    The purpose of this article is to provide an overview of the specific configuration files that are used to configure the software. It explains the configuration hierarchy and identifies the location of key configuration files and what application configuration variables are set within those files.

    Configuration Hierarchy

    The configuration system is comprised of various configuration files which are organized in a hierarchy. When the software is started, it loads the configuration files in accordance with the hierarchy in the following order:

    1. System
    2. Organization
    3. Workspace
    4. WorkSet
    5. Role
    6. User

    Note: If any given variable is set in multiple configuration files at different levels of the hierarchy, the value set in the last loaded file will override the previously set values.

    Configuration Files

    After a default installation of the software, Bentley Substation deploys two workspaces entitled, “Substation ANSI-IEEE Example" and "Substation IEC Example.” The Substation Configuration Variables are defined in configuration files named, “Substation.cfg” which are located at the Workspace and WorkSet levels of the configuration hierarchy.

    Workspace Configuration File

    The application Workspace configuration file is found here:

    …\ Configuration \ WorkSpaces \ Substation ANSI-IEEE Example\ Standards \ Substation \ Substation.cfg

    …\ Configuration \ WorkSpaces \ Substation IEC Example\ Standards \ Substation \ Substation.cfg

    At a high level, this configuration file loads the following information:

    • Databases (parts database, multi-language.mdb)
    • Catalogs (symbols/macros/families)
    • Profiles (Device ID formats, Wire Tag formats, etc.)
    • Templates (Reports, Graphical Plans, etc.)

    This configuration file makes use of the following Substation configuration variables:

    • ELEC_DRAWING_STANDARD
    • ELEC_WORKSETSTANDARDS
    • ELEC_WORKSETDGNS
    • ELEC_PARTS_DB_MAPPING_PATH
    • ELEC_LANGUAGE_DB_PATH
    • ELEC_SYSTEM_OPTION_PROFILE  
    • ELEC_USER_OPTION_PROFILE
    • ELEC_PRJ_PROFILE_DIR
    • ELEC_PAGE_FORMAT_DIR
    • ELEC_TEMPLATES_GRAPHICPLAN_DIR
    • ELEC_TEMPLATES_PAGE_DIR
    • ELEC_TEMPLATES_REPORT_DIR
    • ELEC_CATALOG_PATH
    • ELEC_ACTIVEPARTSDATABASE
    • ELEC_PROJECT_OPTION_PROFILE
    • ELEC_SHOW_PWCHECKIN_DIALOG
    • ELEC_DEFAULT_PROJECT_DIR
    • ELEC_ENABLE_MANAGED_CONFIGURATION
    • Additional variables that are used exclusively for a ProjectWise Managed WorkSpace are also found here.

    For details on the purpose of each of these variables please refer to the Configuration Variables article.

    WorkSet Configuration File

    The application WorkSet configuration file is found here:

    ...\Configuration\WorkSpaces\Substation ANSI-IEEE Example\Worksets\Substation_Sample_ANSI-IEEE\Standards\Substation\Substation.cfg

    ...\Configuration\WorkSpaces\Substation IEC Example\Worksets\Substation_Sample_IEC\Standards\Substation\Substation.cfg

    The default WorkSet configuration files provided with the software do not set any Substation specific variables since they are set at the WorkSpace level.  If you want to override any configuration settings at the WorkSpace level you may specify Substation configuration variables in this file and set the desired values for them. 

    For a list of the configuration variables refer to the Configuration Variables article.

    • CONNECT Edition
    • administration
    • Bentley Substation
    • en
    • Installation_Configuration
    • Share
    • History
    • More
    • Cancel
    • Scott Walker Created by Bentley Colleague Scott Walker
    • When: Tue, Mar 5 2019 5:11 PM
    • Satish Saptasagar Last revision by Bentley Colleague Satish Saptasagar
    • When: Wed, Apr 15 2020 1:09 PM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies