Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenUtilities
  • Product Communities
OpenUtilities
OpenUtilities Wiki Working with Template WorkSets - Bentley Substation v10.03+
    • Sign In
    • +OpenUtilities
    • Access Service Request Manager
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities sisNET - English
    • -OpenUtilities Substation
      • -CONNECT Edition - OpenUtilities Substation
        • +3D Layout Features - OpenUtilities-Substation
        • +Administration Features - OpenUtilities Substation
        • +Automation Feature
        • +Component management - OpenUtilities Substation CONNECT
        • +Components Features - Substation CONNECT
        • +Construction Drawing - Openutilities Substation CONNECT
        • +Database Platform Support - OpenUtilities Substation
        • +Drawing Managment - OpenUtilities Substation
        • -Installation_Configuration - Bentley Substation CONNECT Edition
          • +Compatibility Chart OpenUtilities Substation CONNECT
          • Configuration Files - Bentley Substation v10.00-10.02
          • Configuration Files - Bentley Substation v10.03+
          • Configuration Variables - Bentley Substation v10.00-10.02
          • Configuration Variables - Bentley Substation v10.03+
          • Creating New WorkSpace & WorkSet - OpenUtilities Substation
          • Deployment Guide - Bentley Substation CONNECT Edition v10.03+
          • Deployment Guide - Substation CONNECT Edition v10.00-10.02
          • Error due to Microsoft Access Database Engine
          • How to Clean Install OpenUtilities Substation
          • How to create Deployment Image for OpenUtilities Substation CONNECT Edition
          • How to Deploy Custom Parts Database Manager layout - OpenUtilities Substation
          • +How to download the Bentley Substation software
          • How to Silent Install OpenUtilities Substation
          • +Installation Errors - Installation_Configuration - OpenUtilities Substation CONNECT Edition
          • Migrating Bentley Substation from V8i to CONNECT Edition - Bentley Substation v10.00-10.02
          • Migrating Bentley Substation from V8i to CONNECT Edition v10.03+
          • Program Data / Configuration Folder
          • Program Folder - OpenUtilities Substation CONNECT
          • System Requirements OpenUtilities Substation CONNECT Edition
          • Working with Template WorkSets - Bentley Substation v10.00-10.02
          • Working with Template WorkSets - Bentley Substation v10.03+
        • +Maintenance Feature - Open Utilities Substation CONNECT
        • +Migration - OpenUtilities Substation CONNECT
        • +OS & Hardware Support - OpenUtilities Substation CONNECT
        • +Panel Layout- Substation CONNECT
        • +Power Platform Support - Substation CONNECT
        • +Print and Plot feature
        • +Print and Publish feature
        • +Project Management - OpenUtilities Substation CE
        • +ProjectWise Integration - OpenUtilities Substation CONNECT
        • +Replace Device ID - Find_Replace - OpenUtilities Substation
        • +Reports_Output Features - OpenUtilities Substation CONNECT
        • +Resolved issues in OpenUtilities Substation Releases
        • +Wire Numbering - Substation CONNECT
        • +Wiring Feature - OpenUtilities Substation
      • +3D Layout Features - Bentley Substation
      • About Bentley Substation
      • +Administration Features - Bentley Substation
      • +Automation Features - Bentley Substation
      • +Component Management - Bentley Substation
      • +Construction Drawings - Bentley Substation
      • +Database Platform Support - Bentley Substation
      • +Grounding Grid - Bentley Substation
      • How to log Service Request
      • +Installation_Configuration - Bentley Substation
      • +Interoperability - Bentley Substation
      • +PowerPlatform Support - Bentley Substation
      • +Project Management - Bentley Substation
      • +ProjectWise Integration - Bentley Substation
      • Working from home with OpenUtilities Substation
    • Promis.e Paths
    • +Promis.e Wiki
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    Working with Template WorkSets - Bentley Substation v10.03+

    Product(s): Bentley Substation CONNECT Edition
    Version(s): 10.03+
    Environment: N/A
    Area: Installation_Configuration
    Subarea: N/A

    Overview

    In the CONNECT Edition, the application makes use of WorkSets to apply configuration settings to projects. Therefore, it can be advantageous to take advantage of template WorkSets to drive the creation of a new WorkSet. By doing so you can apply project specific settings to any new project that you create. Here are some typical uses for a template WorkSet:

    • Specify a project specific catalog or parts database.
    • Load a specific project options file.

    How to Define Template WorkSets

    A template WorkSet is no different than any other WorkSet except for how you intend to use it. In other words, any WorkSet can be treated as a template to create a new WorkSet from.

    You have two options for defining template Worksets:

    1. Customize the existing templates
    2. Create new templates

    Customize the Existing Templates

    You can make use of the existing template WorkSets to preload your own custom content as needed. By default, Substation delivers two template WorkSets that can be used to create a new WorkSet which predefines various configuration variables. The template WorkSets that are delivered by default are:

    • _Template_ANSI-IEEE
    • _Template_IEC

    You can rename these templates, if desired, by renaming the WorkSet folder and the corresponding WorkSet.cfg file. By default, these WorkSets are found in the example workspaces found here:

    C:\ProgramData\Bentley\Bentley Substation CONNECT Edition\Configuration\WorkSpaces\Substation ANSI-IEEE Example\Worksets

    C:\ProgramData\Bentley\Bentley Substation CONNECT Edition\Configuration\WorkSpaces\Substation IEC Example\Worksets

    To modify configuration settings for a template WorkSet you can directly edit the configuration file. The configuration file for the template WorkSet has the same name as the template WorkSet itself and is located in the root of the “WorkSets” folder listed above.

    You can specify any configuration variable you desire and set its value in this configuration file to achieve your desired goal. Please refer to this article for a complete listing of the application specific Configuration Variables. The following example would load project specific catalogs when creating a new project using this WorkSet as a template:

    ELEC_CATALOG_PATH               = //MyNetwork/Catalogs/ProjectCatalogs/

    Create New Templates

    You can select the WorkSet picker in the Project Manager and press the Create WorkSet button to create a new WorkSet and assign it the name of the template you would like to create. Once the WorkSet is created, you can edit the configuration file that matches the name you assigned to the WorkSet.

    You can specify any configuration variable you desire and set its value in this configuration file to achieve your desired goal. Please refer to this article for a complete listing of the application specific Configuration Variables. The following example would load a project specific catalog when creating a new project using this workset as a template:

    ELEC_CATALOG_PATH               = //MyNetwork/Catalogs/ProjectCatalogs/

    How to Utilize a Template WorkSet

    1. Select the WorkSet picker in the Project Manager and press the Create WorkSet button to display the Create WorkSet dialog.
    2. Specify a name for the WorkSet you wish to create.
    3. Choose your template WorkSet from the Template pull-down.
    4. After clicking OK to create the WorkSet the software will copy all contents from the template WorkSet to the newly created WorkSet which includes the configuration file that contains your custom settings.

    Note: Any files you include within the template WorkSet folder will be copied to your newly created WorkSet.

    • CONNECT Edition
    • Administration
    • Bentley Substation
    • en
    • Installation_Configuration
    • Share
    • History
    • More
    • Cancel
    • Scott Walker Created by Bentley Colleague Scott Walker
    • When: Wed, Mar 6 2019 11:23 AM
    • Satish Saptasagar Last revision by Bentley Colleague Satish Saptasagar
    • When: Fri, Apr 17 2020 9:31 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies