Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenUtilities
  • Product Communities
OpenUtilities
OpenUtilities Wiki Compatibility Chart - OpenUtilities Substation CONNECT (Update1 to Update7)
    • Sign In
    • +OpenUtilities
    • Access Service Request Manager
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities sisNET - English
    • -OpenUtilities Substation
      • -CONNECT Edition - OpenUtilities Substation
        • +3D Layout Features - OpenUtilities-Substation
        • +Administration Features - OpenUtilities Substation
        • +Automation Feature
        • +Component management - OpenUtilities Substation CONNECT
        • +Components Features - Substation CONNECT
        • +Construction Drawing - Openutilities Substation CONNECT
        • +Database Platform Support - OpenUtilities Substation
        • +Drawing Managment - OpenUtilities Substation
        • -Installation_Configuration - Bentley Substation CONNECT Edition
          • -Compatibility Chart OpenUtilities Substation CONNECT
            • Compatibility Chart - OpenUtilities Substation CONNECT (Update1 to Update7)
            • Compatibility Chart - OpenUtilities Substation CONNECT (Update13 & 14)
            • Compatibility Chart - OpenUtilities Substation CONNECT (Update8 to Update12)
          • Configuration Files - Bentley Substation v10.00-10.02
          • Configuration Files - Bentley Substation v10.03+
          • Configuration Variables - Bentley Substation v10.00-10.02
          • Configuration Variables - Bentley Substation v10.03+
          • Creating New WorkSpace & WorkSet - OpenUtilities Substation
          • Deployment Guide - Bentley Substation CONNECT Edition v10.03+
          • Deployment Guide - Substation CONNECT Edition v10.00-10.02
          • Error due to Microsoft Access Database Engine
          • How to Clean Install OpenUtilities Substation
          • How to create Deployment Image for OpenUtilities Substation CONNECT Edition
          • How to Deploy Custom Parts Database Manager layout - OpenUtilities Substation
          • +How to download the Bentley Substation software
          • How to Silent Install OpenUtilities Substation
          • +Installation Errors - Installation_Configuration - OpenUtilities Substation CONNECT Edition
          • Migrating Bentley Substation from V8i to CONNECT Edition - Bentley Substation v10.00-10.02
          • Migrating Bentley Substation from V8i to CONNECT Edition v10.03+
          • Program Data / Configuration Folder
          • Program Folder - OpenUtilities Substation CONNECT
          • System Requirements OpenUtilities Substation CONNECT Edition
          • Working with Template WorkSets - Bentley Substation v10.00-10.02
          • Working with Template WorkSets - Bentley Substation v10.03+
        • +Maintenance Feature - Open Utilities Substation CONNECT
        • +Migration - OpenUtilities Substation CONNECT
        • +OS & Hardware Support - OpenUtilities Substation CONNECT
        • +Panel Layout- Substation CONNECT
        • +Power Platform Support - Substation CONNECT
        • +Print and Plot feature
        • +Print and Publish feature
        • +Project Management - OpenUtilities Substation CE
        • +ProjectWise Integration - OpenUtilities Substation CONNECT
        • +Replace Device ID - Find_Replace - OpenUtilities Substation
        • +Reports_Output Features - OpenUtilities Substation CONNECT
        • +Resolved issues in OpenUtilities Substation Releases
        • +Wire Numbering - Substation CONNECT
        • +Wiring Feature - OpenUtilities Substation
      • +3D Layout Features - Bentley Substation
      • About Bentley Substation
      • +Administration Features - Bentley Substation
      • +Automation Features - Bentley Substation
      • +Component Management - Bentley Substation
      • +Construction Drawings - Bentley Substation
      • +Database Platform Support - Bentley Substation
      • +Grounding Grid - Bentley Substation
      • How to log Service Request
      • +Installation_Configuration - Bentley Substation
      • +Interoperability - Bentley Substation
      • +PowerPlatform Support - Bentley Substation
      • +Project Management - Bentley Substation
      • +ProjectWise Integration - Bentley Substation
      • Working from home with OpenUtilities Substation
    • Promis.e Paths
    • +Promis.e Wiki
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    Compatibility Chart - OpenUtilities Substation CONNECT (Update1 to Update7)

      Product(s): OpenUtilities Substation
      Version(s): 10.00.XX.XX to 10.07.02.XX
      Environment: N/A
      Area: Installation_Configuration
      Subarea: N/A

    The purpose of this document is to indicate the compatibility of various software with OpenUtilities Substation CONNECT.  It is not intended to describe the compatibility of the various software with each other.  For example, certain versions of SQL Server may not be compatible with certain operating systems.  Always check the documentation of the various software involved.


                         
      Substation / OpenUtilities Substation CONNECT Edition  Update 7 (10.07.00.46) Update 6  (10.06.00.22) Update 5 (10.05.00.35) Update 4  (10.04.00.30) Update 3 (10.03.00.42) CONNECT Update 2 (10.02.00.31) Update 1 (10.01.00.23) Update (10.00.00.232)  
                         
      Operating System                  
      Windows 10 (64-bit) Yes  Yes  Yes  Yes  Yes  Yes  Yes  Yes   
      Windows 8.1 (64-bit) Yes  Yes  Yes  Yes  Yes  Yes  Yes  Yes   
      Windows 7 (64-bit) No 2* 2* 2* 2* 2* 2* 1*  
      Windows Server 2019 (64-bit) Yes  No No No No No No No  
      Windows Server 2016 (64-bit) Yes  Yes               
      Windows Server 2012 (64-bit) Yes  Yes  Yes  Yes  Yes  Yes  Yes  Yes   
      Windows Server 2008 R2 (64 bit)           Yes  Yes  Yes   
         
      Database Software                  
      SQL Server 2019 (Inclusing Express) Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes*  
      SQL Server 2017 (Inclusing Express) Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes*  
      SQL Server 2016 (Including Express) Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes*  
      SQL Server 2014 (Including Express) Yes* Yes* Yes* Yes* Yes* Yes* Yes* Yes*  
      SQL Server 2012 (Including Express)         Yes* Yes* Yes* Yes*  
                         
      ProjectWise Integration                  
      ProjectWise CONNECT 10.00.03.434                  
      ProjectWise CONNECT 10.00.03.334                  
      ProjectWise CONNECT 10.00.03.329 Yes                
      ProjectWise CONNECT 10.00.03.280 Yes Yes              
      ProjectWise CONNECT 10.00.03.271 Yes Yes Yes            
      ProjectWise CONNECT 10.00.03.262 Yes Yes Yes Yes  Yes         
      ProjectWise CONNECT 10.00.03.167 Yes Yes Yes Yes  Yes  Yes       
      ProjectWise CONNECT 10.00.03.140 No No No No No No No No  
      ProjectWise CONNECT 10.00.03.49         Yes  Yes  Yes  Yes   
      ProjectWise CONNECT 10.00.02.320 No No No No No No Yes  Yes   
      ProjectWise CONNECT 10.00.02.265 No No No No No No Yes  Yes   
                         



    1* Limited support. Tested with Windows 7 SP1. In Windows 7 SP1, Backup Project, Copy Project (to another database) and Move To Database functions do not work. This is resolved in CONNECT Edition Update 1.

    2* Requires Windows 7 SP1 Operating System.

    Important Notes

    • Bentley Substation CONNECT Edition is a 64-bit application, compatible only with 64-bit operating systems.
    • Microsoft Office, specifically Microsoft Access, is not required to be installed to use Bentley Substation.
      • For Bentley Substation CONNECT Edition, if Microsoft Office (specifically Microsoft Access) is installed, only 64-bit Microsoft Office is supported. Using 32-bit Office with Bentley Substation CONNECT Edition can result in error messages and an inability to use Bentley Substation and/or Microsoft Office applications.
    • The Cells Marked with * indicates that the particular version of OpenUtilities Substation is only compatible with SQL Server on local Machine or Network Server location and not Compatible with SQL Server hosted on Azure / Cloud Server.

    See Also

    Project Database Version - Substation

    Readme for Bentley Substation CONNECT Edition Update 1

    Readme for Bentley Substation CONNECT Edition

    Compatibility Chart - Substation

    • CONNECT Edition
    • Database Platform Support
    • Compatibility chart
    • substation CONNECT
    • Bentley Substation
    • en
    • Installation_Configuration
    • ProjectWise integration
    • Share
    • History
    • More
    • Cancel
    • Satish Saptasagar Created by Bentley Colleague Satish Saptasagar
    • When: Tue, Apr 2 2019 1:55 PM
    • Satish Saptasagar Last revision by Bentley Colleague Satish Saptasagar
    • When: Mon, Apr 26 2021 9:33 AM
    • Revisions: 21
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies