Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
OpenUtilities
OpenUtilities Wiki
Resolved issues in OpenUtilities Substation CONNECT Edition Update 7, 10.07.00.46
Sign In
+
OpenUtilities
Access Service Request Manager
Design Features - promis.e Functionality - Promis.e Standard
+
OpenUtilities sisHYD Multi Utility
+
OpenUtilities sisNET - English
-
OpenUtilities Substation
-
CONNECT Edition - OpenUtilities Substation
+
3D Layout Features - OpenUtilities-Substation
+
Administration Features - OpenUtilities Substation
+
Automation Feature
+
Component management - OpenUtilities Substation CONNECT
+
Components Features - Substation CONNECT
+
Construction Drawing - Openutilities Substation CONNECT
+
Database Platform Support - OpenUtilities Substation
+
Drawing Managment - OpenUtilities Substation
+
Installation_Configuration - Bentley Substation CONNECT Edition
+
Maintenance Feature - Open Utilities Substation CONNECT
+
Migration - OpenUtilities Substation CONNECT
+
OS & Hardware Support - OpenUtilities Substation CONNECT
+
Panel Layout- Substation CONNECT
+
Power Platform Support - Substation CONNECT
+
Print and Plot feature
+
Print and Publish feature
+
Project Management - OpenUtilities Substation CE
+
ProjectWise Integration - OpenUtilities Substation CONNECT
+
Replace Device ID - Find_Replace - OpenUtilities Substation
+
Reports_Output Features - OpenUtilities Substation CONNECT
-
Resolved issues in OpenUtilities Substation Releases
Resolved issues in Bentley Substation CONNECT Edition, 10.00.00.232
Resolved issues in Bentley Substation CONNECT Edition Update 1, 10.01.00.23
Resolved issues in Bentley Substation CONNECT Edition Update 2, 10.02.00.31
Resolved issues in Bentley Substation CONNECT Edition Update 3, 10.03.00.42
Resolved issues in Bentley Substation CONNECT Edition Update 4, 10.04.00.30
Resolved issues in Bentley Substation CONNECT Edition Update 5, 10.05.00.35
Resolved issues in OpenUtilities Substation CONNECT Edition 2023
Resolved issues in OpenUtilities Substation CONNECT Edition Update 10, 10.10.00.20
Resolved issues in OpenUtilities Substation CONNECT Edition Update 11, 10.11.00.22
Resolved issues in OpenUtilities Substation CONNECT Edition Update 12, 10.12.00.60
Resolved issues in OpenUtilities Substation CONNECT Edition Update 13, 10.13.00.84
Resolved issues in OpenUtilities Substation CONNECT Edition Update 14, 10.14.00.92
Resolved issues in OpenUtilities Substation CONNECT Edition Update 15, 10.15.00.57
Resolved issues in OpenUtilities Substation CONNECT Edition Update 6, 10.06.00.22
Resolved issues in OpenUtilities Substation CONNECT Edition Update 7, 10.07.00.46
Resolved issues in OpenUtilities Substation CONNECT Edition Update 8, 10.08.00.34
Resolved issues in OpenUtilities Substation CONNECT Edition Update 9 Refresh 1, 10.09.01.20
Resolved issues in OpenUtilities Substation CONNECT Edition Update 9 Refresh 2, 10.09.02.23
Resolved issues in OpenUtilities Substation CONNECT Edition Update 9, 10.09.00.10
+
Wire Numbering - Substation CONNECT
+
Wiring Feature - OpenUtilities Substation
+
3D Layout Features - Bentley Substation
About Bentley Substation
+
Administration Features - Bentley Substation
+
Automation Features - Bentley Substation
+
Component Management - Bentley Substation
+
Construction Drawings - Bentley Substation
+
Database Platform Support - Bentley Substation
+
Grounding Grid - Bentley Substation
How to log Service Request
+
Installation_Configuration - Bentley Substation
+
Interoperability - Bentley Substation
+
PowerPlatform Support - Bentley Substation
+
Project Management - Bentley Substation
+
ProjectWise Integration - Bentley Substation
Working from home with OpenUtilities Substation
Promis.e Paths
+
Promis.e Wiki
Replace Family - Find_Replace - Promis.e
SQL Server Login
You are currently reviewing an older revision of this page.
History
View current version
Resolved issues in OpenUtilities Substation CONNECT Edition Update 7, 10.07.00.46
Area Description
ATP
The part number displays not correct and Update Wiring Diagram reports an error for multiple placement symbols.
Balloons
Balloon numbering by the installation is not working correctly.
Balloons
Remove limitation for an only a single set of Balloons allowed per part number per page
Balloons
An error about balloon pops up when I restore the sample project “Sample Washer”.
BOM Explorer
Removing unplaced devices removes device part numbers associated with a BOM Document
BOM Manager
Unnecessary record created in dbo.BMData when the user moves a record to a BOM Document
BOM Manager
Unnecessary record created in dbo.BMDocument when the user attempts to Save without entering a value in New BOM field
BOM Manager
Do No Purchase value 'Yes' not saved
BOM Manager
Unnecessary record left in dbo.BMData when the user changed Do No Purchase to No while all other user fields are Null or Blank
BOM Manager
Brackets [ ] remain in Insert Substation Objects - Symbol By Device ID after the user has renamed a temporary Device Tag
BOM Manager
Changes to Parts Database fields are not applied to existing records in the data grid when the user has configured source DB to use SQL Parts Database
BOM Manager
Incorrect field display name in Create Custom Part dialog for additional fields being added
BOM Manager
Renumbering balloon values skips numbers regardless of balloon setting "No Limitation"
BOM Manager
Unnecessary records left in dbo.ParentDeviceAttribute after the symbol is placed
BOM Manager
The revision number cannot be displayed in the tree view in time if there are two work orders in the BOM Manager dialog.
BOM Manager
Some copied values are missing and an error appears after Running Validation
BOM Manager
In BOM Manager dialog, input lower cases letter for installation and location, it should display Capital letters
BOM Manager
NoCoded Parts display wrong field value
BOM Manager
Mapping the variable Part Number in Options will report an error
BOM Manager
Unhandled Error Message when adding part which contains ' character (Single Quote) in a parts database field
BOM Manager
Parts database field not updating after the user changes a device's part number
BOM Manager
Unnecessary fields populated for Coded parts in dbo.BMData table
BOM Manager
Auto-assigned balloon number not within BOM Document Revision range.
BOM Manager
The "memo1" value cannot be displayed in the BOM Manager
BOM Manager
An internal error loop when the user selects Show Auto Filter Row
BOM Manager
Added new attribute and custom part with the new attribute in the BOM Manager creates an error
BOM Manager
Fields in data grid not populated with parts database value for Non-Coded Part numbers
BOM Manager
Filtering capability select all doesn't account for filtered items
BOM Manager
The device can end up with multiple BOM Document Numbers
BOM Manager
Unable to add NamePlate to Nameplate view when "isNameplate" field value is True, when using "Parts Database" record data source option
BOM Manager
When new BOM Document Revision is created in the BOM Manager, the user cannot select a different work order
BOM Manager
BOM Manager reports an error when adding part from the part database and add the device in the BOM Manager
BOM Options
Adding duplicate attributes for Nameplate should not be allowed
BOMManager
An error occurs when loading existing work order in the BOM Manager with the user's database and user's project
BOMManager
An error message occurs when submitting SAP when the balloon number is blank
Command Protection
The Enable command protection toggle is changed to unchecked when initially used without ProjectWise integration and later launched with ProjectWise Integration
Components Center
Change local catalog's icon in Catalog Manager as it is same as Insert Symbol by Name
Configuration Variables
User not able to Modify Project while using Custom WorkSpace
Configuration Variables
Catalog path is empty in the Modify Catalog Paths dialog
Configuration Variables
After creating one Parts database based on SQL data, it reports an error with Edit all parts database in the Configuration Variables
Configuration Variables
SQL Parts Database path edit removed the connection string details
Configuration Variables
Deployment of dbsettings.xml for users doesn't log in to the database as the password is not populated
Copy Page
The wire number in the Wiring Manager dialog in not maintained for the newly copied page
Copy Page
The wrong installation and location is copied in the newly copied page
Copy Page
Wire number's Prefix and Suffix are not preserved for copied pages
Copy Project
When trying to Copy Project, Create Project Database dialog pops up
Create Symbol
Add a new cross-reference text, the text name is not correct
Create Symbol
Change the new tab name from “Balloon Number Attributes” to “Balloon Attributes”
Device Usage Chart
An error message occurs when clicking the OK button in the Device Usage Chart dialog
DTM
The Substation will crash after selecting the DTM
Exchange
Exchange Equipment Number gives Unhandled Exception Error message
Graphical Parts List
All the data in the drawings are missing after running Graphical Parts List within ProjectWise environment
Help File
The link of Help document needs to be added for Backup Project
Help File
The help document is not loaded for AutoBackup Settings dialog
Help File
Incorrect Help details for BOM Manager (PartsAttributeMapping)
Insert Macro
Click Place Macro button in the Insert Symbol/Macro dialog, the software crashed.
Insert Macro
The message “The physical file "" does not exist in catalog directory. ”is displayed when inserting macro from the Components Center
Insert Symbol
The software crashed with Multiple Placement of symbol
Insert Symbol
Right-click a 3D object, click Properties, it popups error dialog.
Configuration Variables
Error “Template file was not found” pops up when we creating the WorkSet with a template.
LCM Settings
It should not allow deleting the default attributes for the LCM in Options
Lightning Protection
Lightning Protection mast is not generated correctly for the user's project
Options
An error appears when adding custom attribute in Life Cycle Manager Settings and selecting Wire Manager
Options
An error appears when selecting New Project -> Options -> System options -> Life Cycle Manager Settings
Options
Reports error when selecting Options > Life Cycle Manager Settings during the creation of the new project.
Options
Component Center is not displayed under System options
Options
Add password Encryption for SQL connection in LCM Settings.
Parts Database
It reports an error with Opening Parts Database Manager according to the user's data
Parts Database
Custom parts database cannot be searched
Performance
Substation: Page opening is very slow in substation and opens quicker in Microstation Mode
Performance
The performance of Project Publisher in Substation CE Update 6 is slower compared to Update 5
Performance
Project Builder in Substation Update 5 is slower than that in Substation CE Update 4.
Performance
Reduce the size of Pending Commands table
Performance
Index optimization for performance improvement
Plugin
Update symbol plugin updates the Part Number for Part with Additional Part
Project Restore
Unhandled / Internal Error message during project restore - Page Table not being populated
Project Restore
An error message occurs when restoring user's project
Project Restore
Project database not listed in Restore Project dialog
ProjectWise
An error pops up after Substation cannot find the local parts database in ProjectWise integration.
ProjectWise
Substation reports an error when generating PLC
ProjectWise
An error pops up when copying project
ProjectWise
Slow performance when opening a file that is already checked out
ProjectWise
Catalog categories cannot be created.
ProjectWise
"Export unmanaged Copy” of ecad.dgn to users dms creates an error message
ProjectWise
ProjectWise Check-in Dialog appears multiple times after selecting “Cancel” to leave file checked out
ProjectWise
Cannot close drawing temp file after saving a symbol in symbol creation
ProjectWise
An error occurs when copying a page with symbols from PW Explorer
ProjectWise
Fail to run this feature in Promis.e with ProjectWise
Properties Control
When BOM Document Number and Revision Number are set as a PickList the Properties Control dialog, a user cannot select the value from the drop-down list.
Properties Control
Change the options from TEXTBOX to COMBOBOX, the inputted values in TEXTBOX cannot be all list in the dropdown list.
Properties Control
The values in the Properties control dialog should display the Value Prompt in LCM Custom Attributes dialog.
PW Explorer Plugin
An error occurs when clicking BOM Manager tab in Options when creating a project from PW Explorer Plugin
PW Explorer Plugin
The Substation will be closed when running Update Server Copy from PW Explorer
Reports
The sorting variables display is not correct after adding to the sorting field
Reports
BOM_Substation_Qty report filters for Work Order, BOM Document Number, and Revision Number not filtering as required
Restore Project
Projects tree needs to be refreshed in order to list the project restored
Restore Project
The restore dialog always pops up when launching Substation (only if user double clicks on .PRJ file prior to launching substation)
Shortest Distance
Shortest distance crashes and reports error
Symbol Creation
Duplication of the symbol while modifying the symbol
Symbol Creation
Creating a new symbol based on Cell Graphics doubles the symbol graphics after the symbol is saved
Symbol Creation
Using shared cells option produces duplicate symbols after the symbol is edited
Symbol Placement
Special character ' in symbol name causes unhandled exception error
Text Settings
Change the default Text Type to Symbol Text in the Edit Text format dialog if the selected circuits include the Symbol Text.
Text Settings
Right-click a Text->Text Settings, the Underline Space does not work in the Edit Text Format dialog.
Title Block Designer
The warning information is not correct when saving the same name title block in a path.
Wiring diagram
Cable cross-references symbols' wiring diagram connection is not updated properly