OpenUtilities Wiki Resolved issues in Promis.e CONNECT Edition Update 5, 10.05.00.38
    • Sign In
    • +OpenUtilities
    • Access Service Request Manager
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities sisNET - English
    • +OpenUtilities Substation
    • Promis.e Paths
    • -Promis.e Wiki
      • -CONNECT Edition - Promis.e
        • +Administration Features - Promis.e CONNECT
        • +Automation Features - Promis.e CONNECT
        • +Component Features - Promis.e CONNECT
        • +Component Management - Promis.e CONNECT
        • +Database Platform Support - Promis.e CONNECT
        • +Drawing Management - Promis.e Connect
        • +Installation_Configuration - Promis.e CONNECT Edition
        • +Maintenance Features - Promis.e CONNECT
        • +Migration - Promis.e CONNECT
        • +OS & Hardware Support - Promis.e CONNECT
        • +Panel Layout Mode - Promis.e CONNECT
        • +Power Platform Support - Promis.e CONNECT
        • +Print and Plot features Promis.e CONNECT
        • +Project Management - Promis.e CONNECT
        • +ProjectWise Integration - Promis.e CONNECT
        • +Reports_Output Features - Promis.e CONNECT
        • -Resolved issues in Promis.e Releases
          • Resolved issues in Promis.e CONNECT Edition 10.00.00.49
          • Resolved issues in Promis.e CONNECT Edition Update 1, 10.01.00.07
          • Resolved issues in Promis.e CONNECT Edition Update 10, 10.10.00.53
          • Resolved issues in Promis.e CONNECT Edition Update 11, 10.11.00.58
          • Resolved issues in Promis.e CONNECT Edition Update 12, 10.12.00.49
          • Resolved issues in Promis.e CONNECT Edition Update 2, 10.02.00.29
          • Resolved issues in Promis.e CONNECT Edition Update 3, 10.03.00.35
          • Resolved issues in Promis.e CONNECT Edition Update 4, 10.04.00.22
          • Resolved issues in Promis.e CONNECT Edition Update 5, 10.05.00.38
          • Resolved issues in Promis.e CONNECT Edition Update 6, 10.06.00.52
          • Resolved issues in Promis.e CONNECT Edition Update 9, 10.09.00.17
          • Resolved issues in Promis.e CONNECT Update 7, 10.07.00.17
          • Resolved issues in Promis.e CONNECT Update 8, 10.08.00.32
        • +Wire Numbering - Promis.e CONNECT
        • +Wiring Feature - Promis.e CONNECT
      • About Promis.e
      • +Administration Features - Promis.e
      • +APIs_VBA - Promis.e
      • +Automation Features - Promis.e
      • +Component Features - Promis.e
      • +Component Management - Promis.e
      • +CONNECT Services - Promis.e
      • +Data Manager - Promis.e
      • +Database Platform Support - Promis.e
      • +Display - Promis.e
      • +Drawing Management - Promis.e
      • +Engineering Design Considerations - Promis.e
      • Error - Object reference...General
      • +Find_Replace - Promis.e
      • Finding the Tutorial
      • +Installation_Configuration - Promis.e
      • +Interoperability - Promis.e
      • +Licensing - Promis.e
      • +Maintenance Features - Promis.e
      • +Migration - Promis.e
      • +OS Support - Promis.e
      • +Panel Layout - Promis.e
      • +Performance - Promis.e
      • +PowerPlatform Support - Promis.e
      • +Print_Publish Features - Promis.e
      • +ProjectWise Integration - Promis.e
      • Promis.e Help file
      • +Reports_Output Features - Promis.e
      • +Template Management - Promis.e
      • +Text Tools - Promis.e
      • Training FAQs
      • +Wire Numbering - Promis.e
      • +Wiring Features - Promis.e
      • +Project Management - Promis.e
      • Promis.e Title
      • Working from home with Promise.e
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    Resolved issues in Promis.e CONNECT Edition Update 5, 10.05.00.38

    Area                                                         Description 

    API Builder Project Description mapping in Excel not correct  ( needs to match the description in Help file)
    ATP The part number displayed is not correct and Update Wiring Diagram reports an error for multiple placement symbols. 
    Balloons Balloon numbering by the installation is not working correctly.
    Balloons Remove limitation for an only a single set of Balloons allowed per part number per page
    Balloons An error about balloon pops up when I restore the sample project “Sample Washer”.
    BOM Explorer Remove Unplaced Devices removes device part numbers associated with a BOM Document
    BOM Manager Unnecessary record created in dbo.BMData when the user moves a record to a BOM Document
    BOM Manager Unnecessary record created in dbo.BMDocument when the user attempts to Save without entering a value in New BOM field
    BOM Manager Do No Purchase value 'Yes' not saved
    BOM Manager The unnecessary record left in dbo.BMData when the user changed Do No Purchase to No while all other user fields are Null or Blank
    BOM Manager Brackets [ ] remain in Insert Promis.e Objects -  Symbol  By Device ID after the user has renamed a temporary Device Tag
    BOM Manager Changes to Parts Database fields are not applied to existing records in the data grid when the user has configured source DB to use SQL Parts Database
    BOM Manager Incorrect field display name in Create Custom Part dialog for additional fields being added
    BOM Manager Renumber balloon values skips numbers regardless of balloon setting "No Limitation"
    BOM Manager Unnecessary records left in dbo.ParentDeviceAttribute after the symbol is placed
    BOM Manager The revision number cannot be displayed in the tree view in time if there are two work orders in the BOM Manager dialog.
    BOM Manager Some copied values are missing and an error appears after Running Validation
    BOM Manager In BOM Manager dialog, input lower cases letter for installation and location, it should display Capital letters
    BOM Manager NoCoded Parts display wrong field value
    BOM Manager Mapping the variable Part Number in Options will report an error
    BOM Manager Unhandled Error Message when adding part which contains ' character (Single Quote) in a parts database field
    BOM Manager Parts database field not updating after the user changes a device's part number
    BOM Manager Unnecessary fields populated for Coded parts in dbo.BMData table
    BOM Manager Auto-assigned balloon number not within BOM Document Revision range.
    BOM Manager It cannot display the memo1 value in the BOM Manager
    BOM Manager Internal Error loop when the user selects Show Auto Filter Row
    BOM Manager Added new attribute and custom part with the new attribute in the BOM Manager creates an error
    BOM Manager Fields in data grid not populated with parts database value for Non-Coded Part numbers
    BOM Manager Filtering capability select all doesn't account for filtered items 
    BOM Manager The device can end up with multiple BOM Document Numbers 
    BOM Manager Unable to add NamePlate to Nameplate view when "isNameplate" field value is True when using "Parts Database" record data source option
    BOM Manager When new BOM Document Revision is created in the BOM Manager, the user cannot select a different work order 
    BOM Manager BOM Manager reports an error when adding a part from the part database and add the device in the BOM Manager
    BOM Options Adding duplicate attributes for Nameplate should not be allowed
    BOMManager An error occurs when loading existing work order in the BOM Manager with the user's database and user's project
    BOMManager An error message occurs when submitting SAP when the balloon number is blank
    Command Protection The Enable command protection toggle is changed to unchecked when initially used without ProjectWise integration and later launched with ProjectWise Integration
    Components Center Change local catalog's icon in Catalog Manager as it is same as Insert Symbol by Name
    Configuration Variables User not able to Modify Project while using Custom WorkSpace
    Configuration Variables It always prompts that the catalog path is empty in the Modify Catalog Paths dialog
    Configuration Variables After creating one Parts database based on SQL data, it reports an error with Edit all parts database in the Configuration Variables
    Configuration Variables SQL Parts Database path edit removed the connection string details
    Configuration Variables Error “Template file was not found” pops up when creating the WorkSet with a template.
    Configuration Variables Deployment of dbsettings.xml for users doesn't log in to the database as the password is not populated
    Copy Page The wire number in the Wiring Manager dialog in not maintained for the new copied page
    Copy Page The wrong installation and location is copied in the newly copied page
    Copy Page Wire number's Prefix and Suffix are not preserved for copied pages
    Copy Project When trying to Copy Project, Create Project Database dialog pops up
    Create Symbol Add a new cross-reference text, the text name is not correct by default
    Create Symbol Change the new tab name from “Balloon Number Attributes” to “Balloon Attributes” 
    Device Usage Chart An error message occurs when clicking the OK button in the Device Usage Chart dialog
    Exchange Exchange Equipment Number gives Unhandled Exception Error message 
    Graphical Parts List All the data in the drawings is missing after running Graphical Parts List within ProjectWise environment 
    Help File  The link of Help document needs to be added for Backup Project
    Help File  The help document is not loaded  for  AutoBackup Settings dialog
    Help File  Incorrect Help details for BOM Manager (PartsAttributeMapping)
    Insert Macro Click Place Macro button in the Insert Symbol/Macro dialog, the software crashed.
    Insert Macro Insert a Macro: ANTIPLUG in the drawing, it popups unexpected dialog.
    Insert Macro  The message “The physical file "" does not exist in catalog directory. ”is displayed  when inserting macro from the  Components Center
    Insert Symbol The software crashed with Multiple Placement of symbol
    LCM Settings Deleting the default attributes for the LCM in Options should not be allowed
    Merge Tool Modifying device tag of the merged symbol popups unexpected error dialog.
    Options An error appears when adding custom attribute in Life Cycle Manager Settings and selecting Wire Manager
    Options An error appears when selecting New Project -> Options -> System options -> Life Cycle Manager Settings
    Options An error pops up when selecting Options > Life Cycle Manager Settings during the creation of the new project.
    Options Component Center is not displayed under System options 
    Options Adding password encryption for SQL connection in LCM Settings.
    Parts Database An error pops up with Opening Parts Database Manager using the user's project
    Parts Database Custom parts database cannot be searched 
    Performance Promis.e page opening is very slow in Promis.e and opens quicker in Microstation Mode
    Performance The performance of Project Publisher in Promis.e CE Update 6 is slower compared to Update 5
    Performance Project Builder in Promis.e Update 5 is slower than that in Promis.e CE Update 4.
    Performance Reducing the size of Pending Commands table
    Performance Index optimization for improving performance
    Plugin Update symbol plugin updates the Part Number for Part with Additional Part
    Project Publisher Promis.e crashes when using Project Publisher (some pages only)
    Project Restore Unhandled / Internal Error message during project restore - Page Table not being populated
    Project Restore An error message occurs when restoring the user's project
    Project Restore Project database not listed in Restore Project dialog
    Project Restore Project database not listed in Restore Project dialog
    ProjectWise An error pops up after Promis.e cannot find the local parts database in ProjectWise integration.
    ProjectWise  Promis.e  reports an error when generating PLC
    ProjectWise  An error pops up when copying project
    ProjectWise  Slow performance when opening a file that is already checked out
    ProjectWise  Catalog categories cannot be created.
    ProjectWise  "Export unmanaged Copy” of ecad.dgn to users DMS folder creates an error message
    ProjectWise  ProjectWise Check-in Dialog appears multiple times after selecting “Cancel” to leave file checked out
    ProjectWise  Cannot close drawing temp file after saving a symbol in symbol creation
    ProjectWise  An error occurs when copying a page with symbols from PW Explorer
    ProjectWise  Failure to run this feature in Promis.e with ProjectWise
    Properties Control When setting the BOM Document Number and Revision Number as PickList, the user cannot select the value from the drop-down list.
    Properties Control Change the options from TEXTBOX to COMBOBOX, the inputted values in TEXTBOX cannot be all list in the drop-down list. 
    Properties Control The values in the Properties control dialog should display the Value Prompt in LCM Custom Attributes dialog.
    PW Explorer Plugin An error occurs when clicking BOM Manager tab in Options when creating a project from PW Explorer Plugin
    PW Explorer Plugin Promise will be closed when running Update Server Copy from PW Explorer
    Reports The sorting variables display is not correct after adding to the sorting field
    Reports BOM_Promis.e_Qty report filters for Work Order, BOM Document Number, and Revision Number not filtering as required
    Restore Project Projects tree needs to be refreshed in order to list the project restored
    Restore Project The restore dialog always pops up when launching Promis.e (only if user double clicks on .PRJ file prior to launching Promis.e)
    Shortest Distance  Shortest distance crashes and reports error
    Symbol Creation Duplication of the symbol while modifying the symbol
    Symbol Creation Creating a new symbol based on Cell Graphics doubles the symbol graphics after the symbol is saved
    Symbol Creation Using shared cells option produces duplicate symbols after the symbol is edited 
    Symbol Placement Special character  ' in symbol name causes unhandled exception error
    Text Settings Change the Default Text Type to Symbol Text in the Edit Text format dialog if the selected circuits include the Symbol Text.
    Text Settings Right-click a Text->Text Settings, the Underline Space does not work in the Edit Text Format dialog.
    Title Block Designer The warning information is not correct when saving the same name title block in a path.
    Wiring diagram Cable cross-references symbols' wiring diagram connection is not updated properly
    • Share
    • History
    • More
    • Cancel
    • Slavica Bozic Created by Bentley Colleague Slavica Bozic
    • When: Wed, May 6 2020 6:15 PM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies