Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenUtilities
  • Product Communities
OpenUtilities
OpenUtilities Wiki How to Silent Install OpenUtilities Substation
    • Sign In
    • +OpenUtilities
    • Access Service Request Manager
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities sisNET - English
    • -OpenUtilities Substation
      • -CONNECT Edition - OpenUtilities Substation
        • +3D Layout Features - OpenUtilities-Substation
        • +Administration Features - OpenUtilities Substation
        • +Automation Feature
        • +Component management - OpenUtilities Substation CONNECT
        • +Components Features - Substation CONNECT
        • +Construction Drawing - Openutilities Substation CONNECT
        • +Database Platform Support - OpenUtilities Substation
        • +Drawing Managment - OpenUtilities Substation
        • -Installation_Configuration - Bentley Substation CONNECT Edition
          • +Compatibility Chart OpenUtilities Substation CONNECT
          • Configuration Files - Bentley Substation v10.00-10.02
          • Configuration Files - Bentley Substation v10.03+
          • Configuration Variables - Bentley Substation v10.00-10.02
          • Configuration Variables - Bentley Substation v10.03+
          • Creating New WorkSpace & WorkSet - OpenUtilities Substation
          • Deployment Guide - Bentley Substation CONNECT Edition v10.03+
          • Deployment Guide - Substation CONNECT Edition v10.00-10.02
          • Error due to Microsoft Access Database Engine
          • How to Clean Install OpenUtilities Substation
          • How to create Deployment Image for OpenUtilities Substation CONNECT Edition
          • How to Deploy Custom Parts Database Manager layout - OpenUtilities Substation
          • +How to download the Bentley Substation software
          • How to Silent Install OpenUtilities Substation
          • +Installation Errors - Installation_Configuration - OpenUtilities Substation CONNECT Edition
          • Migrating Bentley Substation from V8i to CONNECT Edition - Bentley Substation v10.00-10.02
          • Migrating Bentley Substation from V8i to CONNECT Edition v10.03+
          • Program Data / Configuration Folder
          • Program Folder - OpenUtilities Substation CONNECT
          • System Requirements OpenUtilities Substation CONNECT Edition
          • Working with Template WorkSets - Bentley Substation v10.00-10.02
          • Working with Template WorkSets - Bentley Substation v10.03+
        • +Maintenance Feature - Open Utilities Substation CONNECT
        • +Migration - OpenUtilities Substation CONNECT
        • +OS & Hardware Support - OpenUtilities Substation CONNECT
        • +Panel Layout- Substation CONNECT
        • +Power Platform Support - Substation CONNECT
        • +Print and Plot feature
        • +Print and Publish feature
        • +Project Management - OpenUtilities Substation CE
        • +ProjectWise Integration - OpenUtilities Substation CONNECT
        • +Replace Device ID - Find_Replace - OpenUtilities Substation
        • +Reports_Output Features - OpenUtilities Substation CONNECT
        • +Resolved issues in OpenUtilities Substation Releases
        • +Wire Numbering - Substation CONNECT
        • +Wiring Feature - OpenUtilities Substation
      • +3D Layout Features - Bentley Substation
      • About Bentley Substation
      • +Administration Features - Bentley Substation
      • +Automation Features - Bentley Substation
      • +Component Management - Bentley Substation
      • +Construction Drawings - Bentley Substation
      • +Database Platform Support - Bentley Substation
      • +Grounding Grid - Bentley Substation
      • How to log Service Request
      • +Installation_Configuration - Bentley Substation
      • +Interoperability - Bentley Substation
      • +PowerPlatform Support - Bentley Substation
      • +Project Management - Bentley Substation
      • +ProjectWise Integration - Bentley Substation
      • Working from home with OpenUtilities Substation
    • Promis.e Paths
    • +Promis.e Wiki
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    How to Silent Install OpenUtilities Substation

      Product(s): OpenUtilities Substation CONNECT
      Version(s): 10.00.XX.XX to 10.07.XX.XX
      Environment: N\A
      Area: Installation_Configuration
      Subarea: N\A

    Background

    The term "Silent installation" mean no user interface, installation wizards, or prompts are presented to the user.  "Deployment image" needs to be created as a pre-configured offline installer. Following are the advantages of using a deployment image:

    • Internet connection is not required on the destination workstations.
    • Downloading and installing pre-requisite packs and other required software on the workstations is not required.
    • The installation and other paths can be set in the deployment image. This results in the product installed to and configured to use the same paths on all workstations.
    • The features and companion applications to be installed are selected when creating deployment image. This results in all workstations having exactly the same installed components.

    Steps to Accomplish

    1. Download the installer for OpenUtilities Substation. Refer the below Wiki Link for steps on How to Download Promis.e CONNECT Installation Package

    How to download the Bentley Substation software
    Product(s): Bentley Substation CONNECT Version(s): 10 Environment: N/A Area: Installation_Configuration Subarea: N/A Steps to Accomplish If…
    Last edited over 3 years ago in OpenUtilities > OpenUtilities Wiki


    2. Once the Installer file is downloaded, Deployment Image needs to be created for Substation CONNECT. The steps to create deployment image can be followed from below Wiki Link.
    How to create Deployment Image for OpenUtilities Substation CONNECT Edition
    Product(s): OpenUtilities Substation CONNECT Version(s): 10.00.XX.XX to 10.06.XX.XX Environment: N/A Area: Installation_Configuration Subarea: Deployment Image…
    Last edited over 3 years ago in OpenUtilities > OpenUtilities Wiki

    3. After the Deployment Image has been created, the Deployment Image Folder needs to be copied / deployed on the Machine locally where Substation CONNECT needs to be installed Silently.
    Note: The Installation Path & Configuration Path Selected while creating Deployment Image will be default Path for Silent Installation unless specified during Silent Installation. 


     
    4. Next the copied Deployment Image folder will contain setup file for Substation CONNECT like example "Setup_Substationx64_10.07.00.046" copy the Mapping Path as Highlighted  in the above image. After the Path is copied open Windows "Command Prompt" by searching in Windows Search.



    5. In Command Prompt dialog Paste the copied Path for the Substation CONNECT Setup file along with Setup file name. Add  space at the end of Path & Setup file and then type in " -q -s -norestart " name without double quotes. Press Enter after competing. Refer the below image for example. This will help in Silent installing Substation CONNECT with the Installation Path and Configuration path details selected while creating Deployment Image. To Install Substation CONNECT in Specific Installation Folder and Configuration Folder go to next step.

    Note: The Installation takes a while to complete  and the time varies from Machine to Machine. After the Installation is complete you will be able to find the Shortcut on Desktop if selected while creating Deployment Image, or "OpenUtilities Substation  CONNECT"  can be searched in the Start Command. 

       


    6. In Command Prompt dialog Paste the copied Path for the Substation CONNECT Setup file along with Setup file name. Add  space at the end of Path & Setup file and then type in InstallDirectory="C:\Bentley\Bentley Substation CONNECT Edition" for location where Promis.e will be installed. Add Space and type in ConfigurationDirectory="C:\ProgramData\Bentley\Substation" to Specify the Path for installing Configuration Folder. Next add Space and type -q -s -norestart. Press Enter after competing. Refer the below image for example.



    External Links

      Original Author:  Satish Saptasagar
    • CONNECT Edition
    • Deployment image
    • en
    • silent install
    • Installation_Configuration
    • OpenUtilities Substation
    • Share
    • History
    • More
    • Cancel
    • Satish Saptasagar Created by Bentley Colleague Satish Saptasagar
    • When: Tue, Jun 2 2020 7:04 AM
    • Satish Saptasagar Last revision by Bentley Colleague Satish Saptasagar
    • When: Tue, Jun 2 2020 7:06 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies