Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenUtilities
  • Product Communities
OpenUtilities
OpenUtilities Wiki How to Specify Default Text Settings for Symbol
    • Sign In
    • +OpenUtilities
    • Access Service Request Manager
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities sisNET - English
    • +OpenUtilities Substation
    • Promis.e Paths
    • -Promis.e Wiki
      • -CONNECT Edition - Promis.e
        • +Administration Features - Promis.e CONNECT
        • +Automation Features - Promis.e CONNECT
        • +Component Features - Promis.e CONNECT
        • -Component Management - Promis.e CONNECT
          • +Catalog Manager - Component Management - Promis.e CONNECT
          • Columns missing from dialogs, error messages in Promis.e Connect
          • -Create Symbol - Component Management - Promise CONNECT
            • Assign part numbers to a symbol definition in Promis.e
            • How to Add Custom Symbol text Attribute in Promis.e CONNECT
            • How to Specify Default Text Settings for Symbol
            • How to use Different Symbol Text Types in Symbol Creation - Promis.e CONNECT
            • Symbol Modification not reflected in Project
          • +Family Creation - Component Management - Promis.e CONNECT
          • +Parts Database - Component Management - Promis.e CONNECT
          • +Replace - Component Management
          • +Terminal Pin-Plug Manager - Component Management - Promise CONNECT
        • +Database Platform Support - Promis.e CONNECT
        • +Drawing Management - Promis.e Connect
        • +Installation_Configuration - Promis.e CONNECT Edition
        • +Maintenance Features - Promis.e CONNECT
        • +Migration - Promis.e CONNECT
        • +OS & Hardware Support - Promis.e CONNECT
        • +Panel Layout Mode - Promis.e CONNECT
        • +Power Platform Support - Promis.e CONNECT
        • +Print and Plot features Promis.e CONNECT
        • +Project Management - Promis.e CONNECT
        • +ProjectWise Integration - Promis.e CONNECT
        • +Reports_Output Features - Promis.e CONNECT
        • +Resolved issues in Promis.e Releases
        • +Wire Numbering - Promis.e CONNECT
        • +Wiring Feature - Promis.e CONNECT
      • About Promis.e
      • +Administration Features - Promis.e
      • +APIs_VBA - Promis.e
      • +Automation Features - Promis.e
      • +Component Features - Promis.e
      • +Component Management - Promis.e
      • +CONNECT Services - Promis.e
      • +Data Manager - Promis.e
      • +Database Platform Support - Promis.e
      • +Display - Promis.e
      • +Drawing Management - Promis.e
      • +Engineering Design Considerations - Promis.e
      • Error - Object reference...General
      • +Find_Replace - Promis.e
      • Finding the Tutorial
      • +Installation_Configuration - Promis.e
      • +Interoperability - Promis.e
      • +Licensing - Promis.e
      • +Maintenance Features - Promis.e
      • +Migration - Promis.e
      • +OS Support - Promis.e
      • +Panel Layout - Promis.e
      • +Performance - Promis.e
      • +PowerPlatform Support - Promis.e
      • +Print_Publish Features - Promis.e
      • +ProjectWise Integration - Promis.e
      • Promis.e Help file
      • +Reports_Output Features - Promis.e
      • +Template Management - Promis.e
      • +Text Tools - Promis.e
      • Training FAQs
      • +Wire Numbering - Promis.e
      • +Wiring Features - Promis.e
      • +Project Management - Promis.e
      • Promis.e Title
      • Working from home with Promise.e
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    How to Specify Default Text Settings for Symbol

      Product(s): Promis.e CONNECt Edition
      Version(s):  10.00.XX.XX to 10.06.XX.XX 
      Environment:  NA
      Area:  Component Management 
      Subarea:  Create Symbol

    Background:

    The default text settings for symbol text for different modes are present in the Project Options settings. The text settings applied to the various text types when Create Symbol is opened can always be changed while in Create Symbol.

    Along with Text Settings Use Text Style and Use Text Height options are provided as highlighted in the below image from Options >> Standards >> Text Settings.  If these options are enabled they will override the text properties given to text in Create Symbol when the symbol is inserted in Projects. The purpose of these settings is to provide a way of making symbol text appear universal throughout a project regardless of how the symbols were created. So it may not be necessary to be concerned about how the text appears while in Create Symbol.  Conversely, it may be best to have the text appear in Create Symbol as it will in the project in order to correctly position it.

    Steps to Accomplish

    Applying the Symbol Text Settings to  particular Project.

    1. If the settings need to be changed for only a particular Project open the Project page.

    2. Select Options from Project Manager and select Standards >> Text Settings. 

    3. Select the Mode for  example Schematic, Panel Mode..... . Then select the Symbol Text  that need to be modified ( Device Id, Connection Point ....) and check Use Text Style and Use Text Height if the specified text settings need to be implemented by overiding the text settings specified while creating symbol. 


    4. Now select Edit to make the changes to the Text Formatting according to requirment and select ok. After making the changes select Ok in Projects Options.


    5. If this settings needs to be applied to all the new Projects then save the Project Options and select it while creating new Project or specify it as default Project Options for the WorkSapce / WorkSet variable. 

      Original Author: Satish Saptasagar
    • Options
    • Create Symbol
    • how to
    • en
    • Promis.e CONNECT Edition
    • Component Management
    • Share
    • History
    • More
    • Cancel
    • Satish Saptasagar Created by Bentley Colleague Satish Saptasagar
    • When: Thu, Jan 28 2021 5:48 AM
    • Satish Saptasagar Last revision by Bentley Colleague Satish Saptasagar
    • When: Thu, Jan 28 2021 5:53 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal