OpenUtilities Wiki Wiring diagram or cable cross reference not populating in report
    • Sign In
    • +OpenUtilities
    • Access Service Request Manager
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities sisNET - English
    • -OpenUtilities Substation
      • -CONNECT Edition - OpenUtilities Substation
        • +3D Layout Features - OpenUtilities-Substation
        • +Administration Features - OpenUtilities Substation
        • +Automation Feature
        • +Component management - OpenUtilities Substation CONNECT
        • +Components Features - Substation CONNECT
        • +Construction Drawing - Openutilities Substation CONNECT
        • +Database Platform Support - OpenUtilities Substation
        • +Drawing Managment - OpenUtilities Substation
        • +Installation_Configuration - Bentley Substation CONNECT Edition
        • +Maintenance Feature - Open Utilities Substation CONNECT
        • +Migration - OpenUtilities Substation CONNECT
        • +OS & Hardware Support - OpenUtilities Substation CONNECT
        • +Panel Layout- Substation CONNECT
        • +Power Platform Support - Substation CONNECT
        • +Print and Plot feature
        • +Print and Publish feature
        • +Project Management - OpenUtilities Substation CE
        • +ProjectWise Integration - OpenUtilities Substation CONNECT
        • +Replace Device ID - Find_Replace - OpenUtilities Substation
        • -Reports_Output Features - OpenUtilities Substation CONNECT
          • -Reporting - Reports_Outputs Features - OpenUtilities Substation
            • Filter a Cable Report in OpenUtilities Substation CONNECT
            • How to Display current date and time on reports in OpenUtilities Substation CONNECT
            • How to Place Report on Drawing using Text On Drawing in OpenUtilities Substation
            • How to Sort Quantified BOM Report Template in Open Utilities Substation
            • Wiring diagram or cable cross reference not populating in report
        • +Resolved issues in OpenUtilities Substation Releases
        • +Wire Numbering - Substation CONNECT
        • +Wiring Feature - OpenUtilities Substation
      • +3D Layout Features - Bentley Substation
      • About Bentley Substation
      • +Administration Features - Bentley Substation
      • +Automation Features - Bentley Substation
      • +Component Management - Bentley Substation
      • +Construction Drawings - Bentley Substation
      • +Database Platform Support - Bentley Substation
      • +Grounding Grid - Bentley Substation
      • How to log Service Request
      • +Installation_Configuration - Bentley Substation
      • +Interoperability - Bentley Substation
      • +PowerPlatform Support - Bentley Substation
      • +Project Management - Bentley Substation
      • +ProjectWise Integration - Bentley Substation
      • Working from home with OpenUtilities Substation
    • Promis.e Paths
    • +Promis.e Wiki
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    Wiring diagram or cable cross reference not populating in report

    Product(s): Promis.e, Bentley Substation
    Version(s): Connect
    Environment: N\A
    Area: Reports_Output Features
    Subarea: Wiring Diagram

    Problem Description

    After inserting a wiring diagram symbol, the connection information such as target device IDs and wire numbers is not populating.

    Steps to Resolve

    The term "the device" in this article refers to the device that is represented by the wiring diagram symbol having the problem. The term "target device" refers to another device connected to "the device".  Additionally, "the device" may be a cable and the wiring diagram symbol may be a cable cross reference symbol.

    Try each suggestion below until the problem is resolved.

    • Run Update Wiring Diagram. Unless "Dynamically update connections" is enabled on the appropriate tabs in Options > Project Options > Wiring Diagram Settings, wiring diagrams must be manually updated.
    • Delete and re-insert the wiring diagram symbol.
    • Ensure the wiring diagram symbol is correctly linked to the device by using Insert Symbol By Device ID to insert the wiring diagram symbol.
    • Check to make sure the schematic symbols for the device are actually connected to the intended target devices. The "Wire without connection" and "Symbol without connection" checks in Engineering Design Considerations are useful for finding problems.
    • When the device is a terminal block, check to make sure the target devices are connected to I (Left) and E (Right) connection points of the terminal block, not the J (jumper) connection points. The Invalid terminal connections check in Engineering Design Considerations is useful for finding such cases. 
    • Check to make sure the pages containing the schematic symbols for the device are not offline.
    • Try inserting the wiring diagram on a different page, or in a different project, and try inserting other wiring diagram symbols on the problem page to try to isolate the problem to the symbol, page, or project.
    • If the connection points on the wiring diagram symbol were manually added or are suspect, import them into the symbol instead.
      1. Open the symbol in Create Symbol.
      2. Set the Number of Connection Points to 0 (zero) on the "Place Connection Points" step to remove the existing connection points.
      3. Go back to the "Import Connection Points" step and import them from the device family or schematic symbol if no family is used with the device.
      4. After importing the connection points, do not make changes in the Visible Text and Hidden Text columns on the "Place Connection Points" step. Insert the connection points onto the symbol drawing.
      5. Finish symbol creation, saving the symbol.
      6. Use Update Symbol to update the project with the new symbol definition if not automatically prompted.

    • Run Rebuild Project Database or run Update Page on the corresponding schematic pages.

      Original Author: Avanti_K

    Keywords: question marks, ?, empty, blank

    • Share
    • History
    • More
    • Cancel
    • Avanti Khandalkar Created by Avanti Khandalkar
    • When: Wed, Feb 17 2021 7:31 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies