This Wiki Article has detailed steps on how to configure and add Name Plate attribute to Parts Database Manager and Part Number.
1. To configure the Name Plate column for parts database, go to Project Manager >> Options >> BOM Manager Settings >> NamePlate Setting >> Select the column for Name Plate.2. Go to Configuration Variables and then edit the parts database to Map the Column from the previous step. Configuration Variables >> Active parts Database name >> Configure Parts Database >> Edit.
3. In the Edit Parts Database dialog select, Next and in the Parts Database Mapping section select the Column configured in Step for Name Plate and then assign it with Insert Name, Display Name & Category, and select Finish.4. Now go to Manage >> Parts Database Manager >> Select Customize Layout.
5. In the Customization Dialog select Layout Tree View >> Select the Name Plate Field and then Drag and Drop it on to the Parts Database Manager to the location as per requirement.
6. Now for the Part Number associated with Name Plate add the value as “True” for the Name Plate attribute.