Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenUtilities
  • Product Communities
OpenUtilities
OpenUtilities Wiki How to Create Configuration Setting Blocks for linking with ProjectWise Managed WorkSpace for ProjectWise Integration - OpenUtilities Substation
    • Sign In
    • +OpenUtilities
    • Access Service Request Manager
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities sisNET - English
    • -OpenUtilities Substation
      • -CONNECT Edition - OpenUtilities Substation
        • +3D Layout Features - OpenUtilities-Substation
        • +Administration Features - OpenUtilities Substation
        • +Automation Feature
        • +Component management - OpenUtilities Substation CONNECT
        • +Components Features - Substation CONNECT
        • +Construction Drawing - Openutilities Substation CONNECT
        • +Database Platform Support - OpenUtilities Substation
        • +Drawing Managment - OpenUtilities Substation
        • +Installation_Configuration - Bentley Substation CONNECT Edition
        • +Maintenance Feature - Open Utilities Substation CONNECT
        • +Migration - OpenUtilities Substation CONNECT
        • +OS & Hardware Support - OpenUtilities Substation CONNECT
        • +Panel Layout- Substation CONNECT
        • +Power Platform Support - Substation CONNECT
        • +Print and Plot feature
        • +Print and Publish feature
        • +Project Management - OpenUtilities Substation CE
        • -ProjectWise Integration - OpenUtilities Substation CONNECT
          • How to Create Configuration Setting Blocks for linking with ProjectWise Managed WorkSpace for ProjectWise Integration - OpenUtilities Substation
          • How to Disable ProjectWise Desktop Integration with Substation CONNECT
          • How to Import Managed WorkSpace file and creating Default Project folders for ProjectWise Integration - OpenUtilities Substation
          • How to Redirect OpenUtilities Substation to access Catalogs outside of ProjectWise location with ProjectWise Managed WorkSpace Integration - OpenUtilities Substation
          • +ProjectWise Integration Error - OpenUtilities Substation
        • +Replace Device ID - Find_Replace - OpenUtilities Substation
        • +Reports_Output Features - OpenUtilities Substation CONNECT
        • +Resolved issues in OpenUtilities Substation Releases
        • +Wire Numbering - Substation CONNECT
        • +Wiring Feature - OpenUtilities Substation
      • +3D Layout Features - Bentley Substation
      • About Bentley Substation
      • +Administration Features - Bentley Substation
      • +Automation Features - Bentley Substation
      • +Component Management - Bentley Substation
      • +Construction Drawings - Bentley Substation
      • +Database Platform Support - Bentley Substation
      • +Grounding Grid - Bentley Substation
      • How to log Service Request
      • +Installation_Configuration - Bentley Substation
      • +Interoperability - Bentley Substation
      • +PowerPlatform Support - Bentley Substation
      • +Project Management - Bentley Substation
      • +ProjectWise Integration - Bentley Substation
      • Working from home with OpenUtilities Substation
    • Promis.e Paths
    • +Promis.e Wiki
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    How to Create Configuration Setting Blocks for linking with ProjectWise Managed WorkSpace for ProjectWise Integration - OpenUtilities Substation

      Product(s): OpenUtilities Substation CONNECT Edition
      Version(s):  10.00.XX.XX to 10.11.XX.XX
      Environment:  NA
      Area:  ProjectWise Integration
      Subarea:  NA

    Background:

    This document can be refer for creating Configuration Settings Block (CSB's) in ProjectWise Administrator for OpenUtilities(OU) Managed WorkSpace. There are three main CSB that are required by OU Substation which are as below. And then Linking there CSB to Work Areas. 

    1. Predefined level CSB called Substation_CE_Configuration.
    2. Global level CSB called Substation_CE_Global_Config_Variables.
    3. Workset/Project level CSB called Substation_CE_Workset_Link. 


    Steps to Accomplish

    Create a Predefined level CSB called Substation_CE_Configuration 

    This CSB defines the location of the folder in ProjectWise that contains the entire Managed WorkSpace.

    1. In ProjectWise Administrator, expand WorkSpaces > Managed then Right-click the Predefined level and select New > Configuration Block.


    2. In the New CSB dialog specify the Name of the of the CSB "Substation_CE_Configuration" and specify any Descriptions and select Apply.




    3. Now click Configuration tab, click "+" and select Add Variable. 



    4. In the New Variable Dialog specify Name as "_USTN_CONFIGURATION", specify the description. check the Locked checkbox and click Add.  




    5. In the Edit Value dialog set the Operator Type as "=" - Assignment >> select the Value Type as ProjectWise Folder and use the browse button to select the WorkSpace folder into which the Managed WorkSpace have been imported and select Ok.



    6. Click Ok on New Variable dialog. 




    7. Click Ok on the Substation_CE_Configuration Properties dialog. 




    Create a Global level CSB called Substation_CE_Global_Config_Variables

    This CSB displays all the system level configuration variables and is useful for administrator during testing and debugging. 

    1. In ProjectWise Administrator, expand WorkSpaces > Managed then Right-click the Global level and select New > Configuration Block.




    2. In the New CSB dialog specify the Name of the of the CSB "Substation_CE_Global_Config_Variables" and specify any Descriptions and select Apply.





    3. Now click Configuration tab, click "+" and select Add Variable. 




    4. In the New Variable Dialog specify Name as "_USTN_DISPLAYALLCFGVARS", specify the description. check the Locked checkbox and click Add.  




    5. In the Edit Value dialog set the Operator Type as "=" - Assignment >> select the Value Type as String and specify value as "1" Ok.




    6. Click Ok on New Variable dialog. 




    7. Click Ok on the Substation_CE_Blobal_Config_Variable Properties dialog. 





    Create Workset/Project level CSB called Substation_CE_Workset_Link

    1. In ProjectWise Administrator, expand WorkSpaces > Managed then Right-click the WorkSet/Project level and select New > Configuration Block. 



    2. In the New CSB dialog specify the Name of the of the CSB "Substation_CE_Workset_Link" and specify any Descriptions and select Apply.



    3. Now click Configuration tab, click "+" and select Add Directive. 





    4. In the New Variable Dialog set Directive as %include specify the description and click Add.  




    5. In the Edit Value dialog set the Value Type as String >> Specify Value as $(dms_project(_dgndir))Substation_Workspace.cfg and click Ok.



    6. Click Ok on New Variable dialog. 


    7. Click Ok on the ubstation_CE_Workset_Link Properties dialog. 




    Steps to Link CSBs to Work Areas

    1. To CSB’s to Default Startup Project. Locate the designated Default Startup Project created after importing the Managed WorkSpace. Refer the Step 2: Create Default Startup Project, from below Wiki Link for more details. 

    How to Import Managed WorkSpace file and creating Default Project folders for ProjectWise Integration...
    Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.00.XX.XX to 10.11.XX.XX Environment: NA Area: ProjectWise Integration Subarea: NA…
    Last edited over 1 year ago in OpenUtilities > OpenUtilities Wiki



    2. Right Click on the Default Startup Project >> WorkSpace >> select WorkSpace Type as Managed >> to assign the CSBs Right Click on each CSB and then choose the Add Association. Select the CSB created in the earlier section of this Wiki Article. 




    3. Select OK to complete the CSB assignment for default startup project. 


    4. Repeat the above steps from 1 to 3, for Default Work Areas for OU Substation. You can Refer the "Step 3: Designate Default Work Area for OpenUtilities Substation Projects" from below Wiki Link for the details on Default Work Area. 

    How to Import Managed WorkSpace file and creating Default Project folders for ProjectWise Integration...
    Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.00.XX.XX to 10.11.XX.XX Environment: NA Area: ProjectWise Integration Subarea: NA…
    Last edited over 1 year ago in OpenUtilities > OpenUtilities Wiki


      Original Author: Satish Saptasagar
    • configuration setting blocks
    • ManagedWorkspace
    • WorkSpace & WorkSet
    • ProjectWise
    • en
    • CSB
    • ProjectWise integration
    • OpenUtilities Substation
    • Share
    • History
    • More
    • Cancel
    • Satish Saptasagar Created by Bentley Colleague Satish Saptasagar
    • When: Thu, Feb 24 2022 8:48 AM
    • Satish Saptasagar Last revision by Bentley Colleague Satish Saptasagar
    • When: Thu, Feb 24 2022 1:01 PM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies