The user is facing the concern that when they try to create new page in for a Project in ProjectWise they face the issue that the Page can be seen in the ProjectWise folder directory but not in the Substation Project Manager.
This issue is caused due to the reason that the Global level CSB which is created to display all the System level configuration variables might have been created Level other than the Global Level like for example it might be created in the Predefined Level.
1. Browse to the Default Project folder using the ProjectWise Explorer and then click Right Click >> Properties >> WorkSpace.2. Remove the CBS with the details "_USTN_DISPLAYALLCFGVARS = 1". from any Level other than Global Level for example as seen in the below image the CSB can be seen in Predefined Level. Right Click >> Remove Association.
3. Now browse to the Root folder which contains the Project for which the page cannot be see in Project Manager Click Right Click >> WorkSpace. Then Remove all the Associated CSB from Predefined, Global, WorkSet/Project, User Levels. Check the option "Replace configuration block associated on all child objects with entries shown here" select OK..