Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenUtilities
  • Product Communities
OpenUtilities
OpenUtilities Wiki Error: Unable to create a new page - OpenUtilities Substation
    • Sign In
    • +OpenUtilities
    • Access Service Request Manager
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities sisNET - English
    • -OpenUtilities Substation
      • -CONNECT Edition - OpenUtilities Substation
        • +3D Layout Features - OpenUtilities-Substation
        • +Administration Features - OpenUtilities Substation
        • +Automation Feature
        • +Component management - OpenUtilities Substation CONNECT
        • +Components Features - Substation CONNECT
        • +Construction Drawing - Openutilities Substation CONNECT
        • +Database Platform Support - OpenUtilities Substation
        • +Drawing Managment - OpenUtilities Substation
        • +Installation_Configuration - Bentley Substation CONNECT Edition
        • +Maintenance Feature - Open Utilities Substation CONNECT
        • +Migration - OpenUtilities Substation CONNECT
        • +OS & Hardware Support - OpenUtilities Substation CONNECT
        • +Panel Layout- Substation CONNECT
        • +Power Platform Support - Substation CONNECT
        • +Print and Plot feature
        • +Print and Publish feature
        • +Project Management - OpenUtilities Substation CE
        • -ProjectWise Integration - OpenUtilities Substation CONNECT
          • How to check if the ProjectWise Wrapper files are present or missing in OpenUtilities Substation
          • How to Create Configuration Setting Blocks for linking with ProjectWise Managed WorkSpace for ProjectWise Integration - OpenUtilities Substation
          • How to Disable ProjectWise Desktop Integration with Substation CONNECT
          • How to Import Managed WorkSpace file and creating Default Project folders for ProjectWise Integration - OpenUtilities Substation
          • How to Redirect OpenUtilities Substation to access Catalogs outside of ProjectWise location with ProjectWise Managed WorkSpace Integration - OpenUtilities Substation
          • Issues working on OpenUtilities Substation with ProjectWise Integration
          • -ProjectWise Integration Error - OpenUtilities Substation
            • Error Message: Last Error 222 when opening a Project Page located in ProjectWise with OpenUtilities Substation CONNECT
            • Error: Unable to create a new page - OpenUtilities Substation
            • Project Page created cannot be seen in Project Manager but can be seen in ProjectWise folder directory - OpenUtilities Substation
            • Symbol graphics are not intelligent when symbol is selected in OpenUtilities Substation
            • Warning: ecad.dgn doesn't exist in 'DefaultProject' in ProjectWise
        • +Replace Device ID - Find_Replace - OpenUtilities Substation
        • +Reports_Output Features - OpenUtilities Substation CONNECT
        • +Resolved issues in OpenUtilities Substation Releases
        • +Wire Numbering - Substation CONNECT
        • +Wiring Feature - OpenUtilities Substation
      • +3D Layout Features - Bentley Substation
      • About Bentley Substation
      • +Administration Features - Bentley Substation
      • +Automation Features - Bentley Substation
      • +Component Management - Bentley Substation
      • +Construction Drawings - Bentley Substation
      • +Database Platform Support - Bentley Substation
      • +Grounding Grid - Bentley Substation
      • How to log Service Request
      • +Installation_Configuration - Bentley Substation
      • +Interoperability - Bentley Substation
      • +PowerPlatform Support - Bentley Substation
      • +Project Management - Bentley Substation
      • +ProjectWise Integration - Bentley Substation
      • Working from home with OpenUtilities Substation
    • Promis.e Paths
    • +Promis.e Wiki
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    Error: Unable to create a new page - OpenUtilities Substation

      Product(s): OpenUtilities Substation CONNECT Edition
      Version(s):  10.00.XX.XX to 10.13.XX.XX
      Environment:  NA
      Area:  ProjectWise Integration
      Subarea:  Error ProjectWise

    Background:

    When creating new Project Page the users may come across the below Alert Message in ProjectWise Managed WorkSpace environment. Below are the reasons for the occurrence. 




    Reason 1:

    There might be a DGN file in the Project Folder with the same file name as the new page file name being created. 


    Reason 2:

    The Project might have the option to save the Pages in Drawing Set Subfolder and the user might not have a "Create Folder Permission" 

    Steps to Resolve: 

    Reason 1: DGN in Project Folder 

    1. In ProjectWise Explorer browse to the location of the Project Folder. 

    2. Then find the DGN with similar name and remove / delete it from the Project Folder. 

    Note: If the DGN is deleted all the information contained in it will be lost. If the DGN was at some point a intelligent Substation Project Page then to try retrieve the original information the user can use the Import Drawing feature. Below is the Wiki Link for the steps on Import Drawings. 

    How to Import Drawings into Projects in OpenUtilities Substation CE
    Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.00.XX.XX to 10.11.XX.XX Environment: N\A Area: Project Management Subarea: Project…
    Last edited over 1 year ago in OpenUtilities > OpenUtilities Wiki


    3. Now try creating a new Page using Substation. 




    Reason 2: Create Folder Permission

    Note: This Step is usually for ProjectWise Administrators as they will need to assign the below folder permission in ProjectWise Explorer.


    1. Open ProjectWise Administrator and login into the Data Source in which the users projects are saved. 

    2. Select Users >> select and right click on the user name to which the permission needs to be added >> Properties.




    3. Select Setting tab >> Folder >> check the "Can Create" option >> Apply & Ok.





      Original Author: Satish Saptasagar
    • error
    • error message
    • en
    • ProjectWise integration
    • OpenUtilities Substation
    • Share
    • History
    • More
    • Cancel
    • Satish Saptasagar Created by Bentley Colleague Satish Saptasagar
    • When: Fri, Sep 2 2022 8:27 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies