<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Balloon Size incorrect when Placing or Moving - OpenUtilities Substation</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/62864/balloon-size-incorrect-when-placing-or-moving---openutilities-substation</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Balloon Size incorrect when Placing or Moving - OpenUtilities Substation</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/62864/balloon-size-incorrect-when-placing-or-moving---openutilities-substation</link><pubDate>Tue, 01 Aug 2023 09:54:41 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:068ccf5d-8ce5-4a65-93ef-047e8f71e3a4</guid><dc:creator>Satish Saptasagar</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/62864/balloon-size-incorrect-when-placing-or-moving---openutilities-substation#comments</comments><description>Current Revision posted to OpenUtilities Wiki by Satish Saptasagar on 8/1/2023 9:54:41 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;OpenUtilities Substation&amp;nbsp;CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;10.00.XX.XX to 10.10.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;NA&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Construction Drawing&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Balloons&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Background:&lt;/h1&gt;
&lt;p&gt;The user might some times observe that when placing or moving the Balloon the Balloon size changes or is smaller compared to the other Balloon on same or different pages even when using same Balloon Style. The reason this might be happning may be due to the reason that &amp;quot;&lt;strong&gt;Annotation Scale Lock&lt;/strong&gt;&amp;quot; is turned off. The Annotation scale Lock is affects Balloon because Insert Balloon Tool leverages MicroStation Power Platform Annotation tool.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/450x250/__key/communityserver-wikis-components-files/00-00-00-00-62/2577.pastedimage1666285966387v1.png" /&gt;&lt;/p&gt;
&lt;h1&gt;Steps to&amp;nbsp;Resolve:&lt;/h1&gt;
&lt;p&gt;1.&amp;nbsp;Open the Project page the issue is being faced.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;2. Change the Workflow from &lt;strong&gt;Electrical&lt;/strong&gt; to &lt;strong&gt;Drawing&lt;/strong&gt; &amp;gt;&amp;gt; &lt;strong&gt;Drawing Aids&lt;/strong&gt; &amp;gt;&amp;gt;select &lt;strong&gt;Annotation Scale Lock&lt;/strong&gt; under &lt;strong&gt;Locks&lt;/strong&gt;.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/550x350/__key/communityserver-wikis-components-files/00-00-00-00-62/0216.jpg" /&gt;&lt;/p&gt;
&lt;h3&gt;&lt;/h3&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Satish Saptasagar&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Construction Drawings, balloon, en, Problem Solving, OpenUtilities Substation&lt;/div&gt;
</description></item><item><title>Balloon Size incorrect when Placing or Moving - OpenUtilities Substation</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/62864/balloon-size-incorrect-when-placing-or-moving---openutilities-substation/revision/2</link><pubDate>Fri, 21 Oct 2022 09:20:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:068ccf5d-8ce5-4a65-93ef-047e8f71e3a4</guid><dc:creator>Satish Saptasagar</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/62864/balloon-size-incorrect-when-placing-or-moving---openutilities-substation#comments</comments><description>Revision 2 posted to OpenUtilities Wiki by Satish Saptasagar on 10/21/2022 9:20:10 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;OpenUtilities Substation&amp;nbsp;CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;10.00.XX.XX to 10.10.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;NA&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Construction Drawing&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;NA&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Background:&lt;/h1&gt;
&lt;p&gt;The user might some times observe that when placing or moving the Balloon the Balloon size changes or is smaller compared to the other Balloon on same or different pages even when using same Balloon Style. The reason this might be happning may be due to the reason that &amp;quot;&lt;strong&gt;Annotation Scale Lock&lt;/strong&gt;&amp;quot; is turned off. The Annotation scale Lock is affects Balloon because Insert Balloon Tool leverages MicroStation Power Platform Annotation tool.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/450x250/__key/communityserver-wikis-components-files/00-00-00-00-62/2577.pastedimage1666285966387v1.png" /&gt;&lt;/p&gt;
&lt;h1&gt;Steps to&amp;nbsp;Resolve:&lt;/h1&gt;
&lt;p&gt;1.&amp;nbsp;Open the Project page the issue is being faced.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;2. Change the Workflow from &lt;strong&gt;Electrical&lt;/strong&gt; to &lt;strong&gt;Drawing&lt;/strong&gt; &amp;gt;&amp;gt; &lt;strong&gt;Drawing Aids&lt;/strong&gt; &amp;gt;&amp;gt;select &lt;strong&gt;Annotation Scale Lock&lt;/strong&gt; under &lt;strong&gt;Locks&lt;/strong&gt;.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/550x350/__key/communityserver-wikis-components-files/00-00-00-00-62/0216.jpg" /&gt;&lt;/p&gt;
&lt;h3&gt;&lt;/h3&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Satish Saptasagar&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Construction Drawings, balloon, en, Problem Solving, OpenUtilities Substation&lt;/div&gt;
</description></item><item><title>Balloon Size not seen correctly when Placing or moving - OpenUtilities Substation</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/62864/balloon-size-incorrect-when-placing-or-moving---openutilities-substation/revision/1</link><pubDate>Thu, 20 Oct 2022 17:13:30 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:068ccf5d-8ce5-4a65-93ef-047e8f71e3a4</guid><dc:creator>Satish Saptasagar</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/62864/balloon-size-incorrect-when-placing-or-moving---openutilities-substation#comments</comments><description>Revision 1 posted to OpenUtilities Wiki by Satish Saptasagar on 10/20/2022 5:13:30 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;OpenUtilities Substation&amp;nbsp;CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;10.00.XX.XX to 10.10.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;NA&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Construction Drawing&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;NA&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Background:&lt;/h1&gt;
&lt;p&gt;The user might some times observe that when placing or moving the Balloon the Balloon size changes or is smaller compared to the other Balloon on same or different pages even when using same Balloon Style. The reason this might be happning may be due to the reason that &amp;quot;&lt;strong&gt;Annotation Scale Lock&lt;/strong&gt;&amp;quot; is turned off. The Annotation scale Lock is affects Balloon because Insert Balloon Tool leverages MicroStation Power Platform Annotation tool.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/450x250/__key/communityserver-wikis-components-files/00-00-00-00-62/2577.pastedimage1666285966387v1.png" /&gt;&lt;/p&gt;
&lt;h1&gt;Steps to&amp;nbsp;Resolve:&lt;/h1&gt;
&lt;p&gt;1.&amp;nbsp;Open the Project page the issue is being faced.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;2. Change the Workflow from &lt;strong&gt;Electrical&lt;/strong&gt; to &lt;strong&gt;Drawing&lt;/strong&gt; &amp;gt;&amp;gt; &lt;strong&gt;Drawing Aids&lt;/strong&gt; &amp;gt;&amp;gt;select &lt;strong&gt;Annotation Scale Lock&lt;/strong&gt; under &lt;strong&gt;Locks&lt;/strong&gt;.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/550x350/__key/communityserver-wikis-components-files/00-00-00-00-62/0216.jpg" /&gt;&lt;/p&gt;
&lt;h3&gt;&lt;/h3&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Satish Saptasagar&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Construction Drawings, balloon, en, Problem Solving, OpenUtilities Substation&lt;/div&gt;
</description></item></channel></rss>