        • Update 7 - Version 10.17.07.17 - 08 March 2023
        • Update 6 - Version 10.17.06.26 - 18 Oct. 2022
        • Update 5 - Version 10.16.05.09 - 11 Feb 2022
        • Update 4 - Version 10.07.04.01 - 29 July 2021
        • Update 3 - Version 10.07.01.01 - 9 April 2021
        • Update 2 - Version 10.06.00.04 - 26 Nov. 2020
        • Update 1 - Version 10.05.00.08 - 17 July 2020
      • +sisNET CE - Enhancements Details
      • +sisNET CE - Oracle Requirements
      • +sisNET CE - Supported Operating Systems
      • +sisNET CE - Software Downloads & Installations
      • +sisNET CE - Changing ProductIDs
      • +sisNET CE - sisNET in virtualized environments
      • sisNET CE - Performance of Reference Files
      • +sisNET V8i - Licensing
    • +OpenUtilities Substation
    • Promis.e Paths
    • +Promis.e Wiki
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    Update 2 - Version 10.06.00.04 - 26 Nov. 2020

    The table below lists the fixes and enhancements in sisNET CONNECT Edition Update 2, with version number 10.06.00.04, released on November 26, 2020. Update 2 was built on PowerPlatform 10.14 and OpenCities Map 10.6.

    ID New  Change  Bug  Description

    308802 

      X   sisVIEW: an independent workflow was defined for sisVIEW (no longer derived from the sisNET ribbon).

    372087 

      X sisNET: Also, for object types that are created with a batch script, the entry in the explorer tree is activated.

    393603 

      X sisNET: The error when calling the SETLEVELSYMBOLOGY macro was fixed.

    420180 

      X sisNET: The final dimension of an orthogonal dimension was not correctly underlined. This is corrected.

    421285 

      X sisNET: Text replacement at the end of plot preparation starts again automatically.

    421938, 446526 

      X sisNET Ribbon: For editing/viewing the print template properties the corresponding icons were missing. The error is now fixed.

    445695 

      X sisNET: The tooltips of the object info box now show the descriptions of the functions instead of the keyboard inputs.

    450319 

      X sisNET: The error in IF ... THEN constructs using the GETOBJID function in commodity macros has been corrected.

    450748 

      X sisNET: The creation of a fence along a linear object (FENCEAREA - macro) works again.

    452528 

      X sisNET: Fixed a crash when saving jobs that contain only non-graphical changes

    453437, 455057 

      X sisNET: Fixed the crash when zooming in/out with the automatic explorer

    453902, 499616, 498969

      X sisNET: Placing/moving/rotating labels now works correctly The GETPNTEXT, SETPNTEXT, SETPNT, PNT macro functions and the rotation of dimension texts have also been corrected.

    455399 

      X sisFLOW: Attributes not relevant to graphics can be changed in the form mask

    460675, 453902 

      X sisNET: The position of the newly placed or edited label was corrected.

    460703 

      X sisNET: The label to be placed (dynamic function) is now displayed with the correct color.

    460809 

      X sisNET: Fixed truncated message when using the TRQS module

    460847 

    X   sisNET: New macro functions:
    - SIN, COS, TAN, ASIN, ACOS, ATAN, ATAN2 have been added to work with angle specifications in radians
    - VECTORDISTANCE serves as a replacement for mdlVec_Distance
    - GETSELECTEDVIEWINDEX as replacement for mdlWindow_getSelectedViewIndex

    466973 

      X sisNET: After starting sisNET the view was sometimes opened very small. This has been fixed.

    468821 

      X sisNET: The EXPANDCFGVAR macro function now also resolves variables containing multiple $(var) expressions.

    473873 

      X sisNET: The error during the initialization of the SROHR module has been fixed.

    476202 

      X sisNET: Stations can be created again with the PROTOTYP module.

    479545 

      X sisNET: the detaching of all raster files was corrected

    479578 

      X sisNET: Fixed the crash in the KSTR module when creating a line with connection to a busbar.

    482128 

      X sisNET: The error when displaying external documents from the form mask was fixed.

    482129 

      X sisNET: the command specific dialog settings (Dialog Tool Settings) have been fixed and are displayed again when a command is activated
    482130   X sisNET: editing as well as executing selection files (*.sel) works again

    482823 

      X sisNET: an sisNET object selected with Microstation element selection can be deleted with the DEL key.

    482824 

      X sisNET: When creating area-shaped objects with hatching, the angle option selected in the "Hatch Settings" dialog is now taken into account.

    482825 

      X sisNET: The bug that caused hatching to be missing in some cases when creating area-shaped objects with hatching has been fixed.

    495792 

      X sisNET: Referencing of DWG files works again.

    500323 

      X sisNET: The error that occurred after editing backstage rights was fixed.
    X   sisIMS-Desktop: with the new 'RedirectWMSService' setting, an external WMS service can be redirected via sisIMS-IIS. This can be used for an HTTPS / HTTP redirection or for calling an external Password-Secured-WMS service. 

    Example 1: HTTPS / HTTP redirection: 
    -Use the following setting in the GRP file responsible for the sisIMS WMS: 
    RedirectWMSService = http: //osmwms.itc-halle.de/maps/osmfree? SERVICE = WMS &  -in the XWMS file the URL line with  <URL> https: // <sisims virtual dir> /wms/request.aspx?service=redirectwms&amp; </URL>.  

    Example 2 redirection with user / password: 
    -Use the following setting in the GRP file responsible for the sisIMS WMS: 
    RedirectWMSService = http: //gdi1.geo.bremen.de/mapproxy/bv_kat/service? 
    RedirectWMSBasicAuthentication = <user>: <password>  -in the XWMS file the URL line with  <URL> https: // <sisims virtual dir> /wms/request.aspx?service=redirectwms&amp; </URL> replace. 
    • sisFlow
    • sisNET
    • sisIMS
    • sisView
    • Share
    • History
    • More
    • Cancel
    • Theo van de Ven Created by Bentley Colleague Theo van de Ven
    • When: Mon, Nov 21 2022 9:01 AM
    • Theo van de Ven Last revision by Bentley Colleague Theo van de Ven
    • When: Wed, Mar 8 2023 2:37 PM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies