<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>How to Create Custom Part Number using BOM Manager in OpenUtilities Substation CONNECT</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/65161/how-to-create-custom-part-number-using-bom-manager-in-openutilities-substation-connect</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to Create Custom Part Number using BOM Manager in OpenUtilities Substation CONNECT</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/65161/how-to-create-custom-part-number-using-bom-manager-in-openutilities-substation-connect</link><pubDate>Tue, 14 Mar 2023 12:42:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:729f10ae-04ed-4b94-8faf-8584b6ea9964</guid><dc:creator>Satish Saptasagar</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/65161/how-to-create-custom-part-number-using-bom-manager-in-openutilities-substation-connect#comments</comments><description>Current Revision posted to OpenUtilities Wiki by Satish Saptasagar on 3/14/2023 12:42:39 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;OpenUtilities Substation&amp;nbsp;CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;10.00.XX.XX to 10.14.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;NA&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Component Management&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;BOM Manager&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Background:&lt;/h1&gt;
&lt;p&gt;Custom Part Numbers are usually used in Project to add a Part to BOM Report as a record, but they are not associated to any symbol in Physical or Control Drawing of the Substation. The Custom Part Number are usually used to Parts like accessories of different equipment like Transformer Nuts and Bolts, Oil for example.&amp;nbsp; &amp;nbsp;&lt;br /&gt;&lt;br /&gt;Also since the these are Custom Part Number they are not stored in the Parts Database but they instead they are stored in the Project.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;1. Click on &lt;strong&gt;Manage&lt;/strong&gt; &amp;gt;&amp;gt; &lt;strong&gt;BOM Manager&lt;/strong&gt; to open BOM Manager dialog.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;img style="max-height:150px;max-width:550px;" alt=" " src="/resized-image/__size/1100x300/__key/communityserver-wikis-components-files/00-00-00-00-62/pastedimage1678797038438v1.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;2.&amp;nbsp; Select the&lt;strong&gt; Work Order&lt;/strong&gt; number &amp;gt;&amp;gt; &lt;strong&gt;BOM Document number&lt;/strong&gt; &amp;gt;&amp;gt; &lt;strong&gt;Revision Number&lt;/strong&gt; under which the Custom Part Number need to be created. Click &lt;strong&gt;Add New&lt;/strong&gt; &amp;gt;&amp;gt; &lt;strong&gt;Part&lt;/strong&gt;.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;img style="max-height:350px;max-width:550px;" alt=" " src="/resized-image/__size/1100x700/__key/communityserver-wikis-components-files/00-00-00-00-62/pastedimage1678797369512v3.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;3. In Add Part Dialog click on &lt;strong&gt;Create Custom Part&lt;/strong&gt; &amp;gt;&amp;gt; In Create Custom Part dialog add the details and descriptions of the Custom Part Number &amp;gt;&amp;gt; Click &lt;strong&gt;Save&lt;/strong&gt; on both the dialogs.&lt;br /&gt;&lt;br /&gt;&lt;img style="max-height:550px;max-width:350px;" alt=" " src="/resized-image/__size/700x1100/__key/communityserver-wikis-components-files/00-00-00-00-62/pastedimage1678797605198v4.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Satish Saptasagar&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: BOM Manager, en, Custom Part Number, Component Management, OpenUtilities Substation&lt;/div&gt;
</description></item><item><title>How to Create Custom Part Number using BOM Manager in OpenUtilities Substation CONNECT</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/65161/how-to-create-custom-part-number-using-bom-manager-in-openutilities-substation-connect/revision/1</link><pubDate>Tue, 14 Mar 2023 12:41:14 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:729f10ae-04ed-4b94-8faf-8584b6ea9964</guid><dc:creator>Satish Saptasagar</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/65161/how-to-create-custom-part-number-using-bom-manager-in-openutilities-substation-connect#comments</comments><description>Revision 1 posted to OpenUtilities Wiki by Satish Saptasagar on 3/14/2023 12:41:14 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;OpenUtilities Substation&amp;nbsp;CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;10.00.XX.XX to 10.14.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;NA&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Component Management&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;NA&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Background:&lt;/h1&gt;
&lt;p&gt;Custom Part Numbers are usually used in Project to add a Part to BOM Report as a record, but they are not associated to any symbol in Physical or Control Drawing of the Substation. The Custom Part Number are usually used to Parts like accessories of different equipment like Transformer Nuts and Bolts, Oil for example.&amp;nbsp; &amp;nbsp;&lt;br /&gt;&lt;br /&gt;Also since the these are Custom Part Number they are not stored in the Parts Database but they instead they are stored in the Project.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;1. Click on &lt;strong&gt;Manage&lt;/strong&gt; &amp;gt;&amp;gt; &lt;strong&gt;BOM Manager&lt;/strong&gt; to open BOM Manager dialog.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;img style="max-height:150px;max-width:550px;" alt=" " src="/resized-image/__size/1100x300/__key/communityserver-wikis-components-files/00-00-00-00-62/pastedimage1678797038438v1.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;2.&amp;nbsp; Select the&lt;strong&gt; Work Order&lt;/strong&gt; number &amp;gt;&amp;gt; &lt;strong&gt;BOM Document number&lt;/strong&gt; &amp;gt;&amp;gt; &lt;strong&gt;Revision Number&lt;/strong&gt; under which the Custom Part Number need to be created. Click &lt;strong&gt;Add New&lt;/strong&gt; &amp;gt;&amp;gt; &lt;strong&gt;Part&lt;/strong&gt;.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;img style="max-height:350px;max-width:550px;" alt=" " src="/resized-image/__size/1100x700/__key/communityserver-wikis-components-files/00-00-00-00-62/pastedimage1678797369512v3.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;3. In Add Part Dialog click on &lt;strong&gt;Create Custom Part&lt;/strong&gt; &amp;gt;&amp;gt; In Create Custom Part dialog add the details and descriptions of the Custom Part Number &amp;gt;&amp;gt; Click &lt;strong&gt;Save&lt;/strong&gt; on both the dialogs.&lt;br /&gt;&lt;br /&gt;&lt;img style="max-height:550px;max-width:350px;" alt=" " src="/resized-image/__size/700x1100/__key/communityserver-wikis-components-files/00-00-00-00-62/pastedimage1678797605198v4.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Satish Saptasagar&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: BOM Manager, en, Custom Part Number, Component Management, OpenUtilities Substation&lt;/div&gt;
</description></item></channel></rss>