Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenUtilities
  • Product Communities
OpenUtilities
OpenUtilities Wiki How to remove "Default WorkSpace & WorkSet Overwritten ...." for Silent Installation of OpenUtilities Substation CONNECT
    • Sign In
    • +OpenUtilities
    • Access Service Request Manager
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities sisNET - English
    • -OpenUtilities Substation
      • -CONNECT Edition - OpenUtilities Substation
        • +3D Layout Features - OpenUtilities-Substation
        • +Administration Features - OpenUtilities Substation
        • +Automation Feature
        • +Component management - OpenUtilities Substation CONNECT
        • +Components Features - Substation CONNECT
        • +Construction Drawing - Openutilities Substation CONNECT
        • +Database Platform Support - OpenUtilities Substation
        • +Drawing Managment - OpenUtilities Substation
        • -Installation_Configuration - Bentley Substation CONNECT Edition
          • +Compatibility Chart OpenUtilities Substation CONNECT
          • Configuration Files - Bentley Substation v10.00-10.02
          • Configuration Files - Bentley Substation v10.03+
          • Configuration Variables - Bentley Substation v10.00-10.02
          • Configuration Variables - Bentley Substation v10.03+
          • Creating New WorkSpace & WorkSet - OpenUtilities Substation
          • Deployment Guide - Bentley Substation CONNECT Edition v10.03+
          • Deployment Guide - Substation CONNECT Edition v10.00-10.02
          • -Deployment Image - OpenUtilities Substation
            • How to create Deployment Image for OpenUtilities Substation CONNECT Edition
            • How to remove "Default WorkSpace & WorkSet Overwritten ...." for Silent Installation of OpenUtilities Substation CONNECT
          • Error due to Microsoft Access Database Engine
          • How to Clean Install OpenUtilities Substation
          • How to Deploy Custom Parts Database Manager layout - OpenUtilities Substation
          • +How to download the Bentley Substation software
          • How to Silent Install OpenUtilities Substation
          • +Installation Errors - Installation_Configuration - OpenUtilities Substation CONNECT Edition
          • Migrating Bentley Substation from V8i to CONNECT Edition - Bentley Substation v10.00-10.02
          • Migrating Bentley Substation from V8i to CONNECT Edition v10.03+
          • Program Data / Configuration Folder
          • Program Folder - OpenUtilities Substation CONNECT
          • System Requirements OpenUtilities Substation CONNECT Edition
          • Working with Template WorkSets - Bentley Substation v10.00-10.02
          • Working with Template WorkSets - Bentley Substation v10.03+
        • +Maintenance Feature - Open Utilities Substation CONNECT
        • +Migration - OpenUtilities Substation CONNECT
        • +OS & Hardware Support - OpenUtilities Substation CONNECT
        • +Panel Layout- Substation CONNECT
        • +Power Platform Support - Substation CONNECT
        • +Print and Plot feature
        • +Print and Publish feature
        • +Project Management - OpenUtilities Substation CE
        • +ProjectWise Integration - OpenUtilities Substation CONNECT
        • +Replace Device ID - Find_Replace - OpenUtilities Substation
        • +Reports_Output Features - OpenUtilities Substation CONNECT
        • +Resolved issues in OpenUtilities Substation Releases
        • +Wire Numbering - Substation CONNECT
        • +Wiring Feature - OpenUtilities Substation
      • +3D Layout Features - Bentley Substation
      • About Bentley Substation
      • +Administration Features - Bentley Substation
      • +Automation Features - Bentley Substation
      • +Component Management - Bentley Substation
      • +Construction Drawings - Bentley Substation
      • +Database Platform Support - Bentley Substation
      • +Grounding Grid - Bentley Substation
      • How to log Service Request
      • +Installation_Configuration - Bentley Substation
      • +Interoperability - Bentley Substation
      • +PowerPlatform Support - Bentley Substation
      • +Project Management - Bentley Substation
      • +ProjectWise Integration - Bentley Substation
      • Working from home with OpenUtilities Substation
    • Promis.e Paths
    • +Promis.e Wiki
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    How to remove "Default WorkSpace & WorkSet Overwritten ...." for Silent Installation of OpenUtilities Substation CONNECT

    -

      Product(s): OpenUtilities Substation CONNECT Edition
      Version(s):  10.00.XX.XX to 10.14.XX.XX
      Environment:  NA
      Area:  Installation_Configuration
      Subarea:  Deployment Image

    Background:

    The User / Admin when deploying OpenUtilities Substation observe that if there is already a previous CONNECT version installed they get message if they need to Backup the Default WorkSpace as seen in below screen shot. This message can cause issues with Silent Installation of OpenUtilities Substation (OUS). This Wiki Article will help users bypass this message when doing a silent installation. 


    Steps to Accomplish

    1. To create Installation Package create a Deployment Image of OUS. Refer the below Wiki Link for steps. 

    How to create Deployment Image for OpenUtilities Substation CONNECT Edition
    Product(s): OpenUtilities Substation CONNECT Version(s): 10.00.XX.XX to 10.06.XX.XX Environment: N/A Area: Installation_Configuration Subarea: Deployment Image…
    Last edited 4 months ago in OpenUtilities > OpenUtilities Wiki




    2. Once the Deployment Image is created go to the location "C:\BentleyDownloads\OpenUtilities Substation CONNECT Edition" and find the file with the extension as *.lyt and open it in Notepad or Notepad++. 




    3. Go to the line that starts with <Feature Id="BackupDefaultWorkspace". Then change value "Selected = Yes" to "No" and "Optional = no" value to "yes" as seen in the below screen shot.  







    4. Now use these Deployment image setup file for creating Silent Installation Deployment Package.

      Original Author: Satish Saptasagar
    • Deployment image
    • backup
    • WorkSpace & WorkSet
    • en
    • silent install
    • Installation_Configuration
    • Share
    • History
    • More
    • Cancel
    • Satish Saptasagar Created by Bentley Colleague Satish Saptasagar
    • When: Tue, May 9 2023 9:35 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies