Resolved issues in OpenUtilities Substation CONNECT Edition Update 15, 10.15.00.57


Product:OpenUtilities Substation
Generation:CONNECT Edition
Version:

Update 15, 10.15.00.57




ADO IDTitle
231062[Balloon]Remove the two toggles in balloon settings.
357275[PW Thematic Manager]Apply the thematic to the symbol and wire, it cannot work connect with PW.
517394[Mode Manager] Parts Database field value reverts back to Schematic_Symbol when adding multiple user defined modes
738771[GraphicalPartsList_PW]An error popup and macros are disappeared when run Graphical Parts List with macros created in new catalog in PW
740622[Upgrade_CommandProtection] The default rights for Administrator and User roles is not correct after upgrading from Substation U9R2
761397[Configuration Variables]An error appears when change Level from WorkSpace to WorkSet with empty value for some variables and click OK
763045[Merge Tool]Move the reference file to other place, and then right click some of circuits, click Merge, it will change the circuits location.
763060[Merge Tool]The activated page will be gray in the Merge Tools dialog. And only the page with the same name should be gray when the toggle is turned on.
763074[Merge Tool]It popups error dialog when attaching the pages from SAMPLE-WASHER in the Merge Tools dialog.
764190[SQL Server] When SQL Server is down the user should not be able to use Power Platform tools in drawings
781028[Wiring Diagram][Navigate]The navigate cannot navigate to the correct devices in the left side of a device in the wiring diagram mode page.
789805[Ribbon][Modify Component] Device commands under ribbon Modify Component report error
792256[Merge Tool]Activate a reference file in reference dialog, and check in Merge tool dialog, and then deactivate it with the reference dialog opened, and it popups error dialog when opening the Merge tool dialog.
800949[Catalog Manager]Create a catalog with symbol or macro under a sample WorkSpace in a released build, upgrade to new version, the catalog is not listed in Catalog Manager 
806258[Configuration Variables] The previous settings for default WorkSpace WorkSet are not overwritten after upgrade 
823145[BOM Manager] It popups error dialog when open BOM Manager dialog in a project with spares added in the Terminal Manager dialog.
868380[Project Table] Modified Time for Project table in database is not updated when some of the commands are used to modify the project 
874606[Lightning Protection] When Lightning Protection Mast Top is processed the Lightning Mast is not generated or the existing Mast is deleted
876416[Copy page] Sometimes part numbers order is not maintained in Device Properties dialog in copied page
885166[Page Management] After click See page pending status, tool bar commands Renumber Page/Modify Page/Copy page occur error 
888546[BOM Manager][Add Part] Unhandled Error message "Value was either too large or too small for an Int32" appears when Balloon Number exceeds 10 Digits
888599[BOM Manager][Add Part]Unhandled Error message "Value was either too large or too small for an Int32" appears when Temp Device Number exceeds 10 Digits
891331[Copy page][SubID] SubID cannot display correctly with multiple part number placement separately in copied page
892389[Run Reports][Project Publisher] when creating Reports or Project drawing Substation replaces the output file with new without any message
894288[PW Integration][Page Rename]When user rename page from PW explorer they don‘t get Substation Page Rename dialog 
896551[Balloon]It should update the balloon values instead of the information dialog in the project with duplicate balloon number.
901315[Place Balloon]It crash or popups error dialog when deleting the balloon number in the Place Balloon dialog and then click a point in the drawing.
903515[PW Integration][Orphaned balloon]It cannot display orphaned balloon in Orphaned Balloon dialog correctly
904302[ProjectWise Integration] Cannot open project pages from Project Manager or ProjectWise explorer
904392[Copy Page][Copy Balloon Callouts] It cannot copy part number attributes value that defined by manual 
914131[Network Project] File Server that have "." in the Server name gives Error Message when loading the application
915573[Wiring Manager]Force the connections->Move Down one of a symbol from Manage->Wiring Manager dialog, the wire properties are missing from the wiring manager dialog.
918340[Insert Symbol]When inserting Linear and Repeating symbols that were saved with "Use Shared Cell" the symbol should be placed on Active Level
923662[Copy from Reference/Merge into Master]Copy from the reference file which has CR symbols with family, and maintain the device complete, the copied CPs are not correct.
927711[Security][Severity:Medium] - Upgrade 'sqlite-amalgamation-3.8.0.2' version.
930408[Balloon] Modify balloon in BOM Manager cannot be updated on drawing 
933279[Wiring Manager] The user is getting Error Message "Exception has been thrown ..." when right click on schematic wire to access Wiring manager
935621The project tree is missing from Project Manager after we create a project in some cases.
936040[BOM Manager]Clear BOM Tree, change Group by from Balloon to Device, devices should not list in the dialog.
936697[BOM Manager][Insert Spare] when user loads data By Work Order Insert Spare function is disabled
937687[PW integration][New Page] New Page in PW Environment reports error if users just have Read permissions on the ProjectOptions.xml file for the Project
937882[Lightning Protection] when using Pick Mast on Lightning Mast saved as a shared cell the Z-coordinates are not updated correctly
948313[Mode Manager] The mapped field for new mode is changed after launch with network location defined in WorkSpaceSetup.cfg and back to local WorkSpaces
962697[Wire Manager] Wire Location and Installation values change after Update Page
965012[iModel Hub][Publish Pages to Server] Point Cloud file not aligned with objects in 3D Page after publish
965867[Insert Cable][Catenary SAG] Cable graphics not generated correctly at the beginning and the end of the cable 
970735[Balloon]Modify balloon values and move it using Balloon_circle without a leader style, it popups error dialog.
970780[BOM Manager][Balloon]Delete one of the balloon circle inserted by Device in the drawing, and then modify the style, the deleted circle will return back.
973200[Thematic Manager] [Apply Thematic] Thematic display does not work for copied symbols or Microstation objects
973440[Thematic Manager][ Apply Thematic] Thematic display does not work with Microstation Solids
980433[Insert Balloon] Insert Balloon not working on some construction drawings 
984795[Data Manager]The value of Mounting location is not correct in the Data Manager dialog.
986747[Thematic Manager][Delete]After delete Microstation objects, it cannot delete all records in dbo.LCM_GraphicalObject table
986766[Thematic Manager][Copy Page] It cannot copy LCM properties to Microstation objects in copied page
992483[PW Integration] [Project Management] It should implement correct pw user read permission for ProjectOption.xml with Project Management commands in PW client side
993155[PW Integration] [Page Management] It should implement correct pw user read permission for ProjectOption.xml with Page Management commands in PW client side
993875[Rotate][Hooked Objects] After clicking Rotate in 3D Layout mode the dialog for options Hooked Object is not visible continuously 
1016014[Thematic Manager][Balloon callout] Balloon callouts cannot be applied thematic display by assigned LCM attributes mannually and data cannot be deleted in dbo table
1017298[PW][Multi-User]The modified/added/removed value in Language Database Manager and Mode Manager is not displayed timely in Multi User mode
1017425[PW][Multi-User]UserA create a symbol, UserB cannot see the symbol in time.
1019046[PW Integration][Title Block Attribute] DrawingSet.TotalPages attributes value is not visible in ProjectWise attributes 
1019376[PW Integration][Active Level]Substation crashes when user tries to change the active level from Drawing Workflow ribbon 
1019658[Balloon]Sometime modify the balloon values, the position is changed if the Dimension style is Balloon_Circle without a leader.
1022713[BOM Manager] During refresh process, click X button in BOM Manager reports error
1023357[BOM Manager]Add device with three part number, and change the Primary part number in the BOM Manager dialog, close and reopen the BOM Manager dialog, the Primary part number is not changed.
1030653[PW] [Multi Users][Remove Catalog.mdb]One user checks out catalog text files, another user saves Macro&Family&Title block should give the correct message dialog.
1034321[Drawing Set] store Drawing Set and Drawing Set Descriptions in DGN file
1034363[Installation Descriptions] store Installation Descriptions in DGN file
1034382[Location Descriptions] store Location Descriptions in DGN file
1034409[Update][Page] push Page Description values from active page into project database
1034422[Balloon Number] store balloon numbers in DGN file
1034466[Page Properties] store Default Page Properties in DGN file
1034483[Import Drawings] automatically populate required fields
1036150[Copy Balloon]The copied balloon callout inserted By Symbol is not correct
1038267[Copy Page] Duplicate Device Id when page copy used with option to not maintain device id 
1038671[Symbol Cross References] cross reference text no longer associated to child elements cannot navigate and Update Page does not resolve issue
1038673[Cable Text] store cable text values in DGN file
1039387[Place Balloon] incorrect sort order when user sorts data grid by Part Number or by Balloon number column
1062093[Restore Project]Restore a project with project catalog created backuped, the project catalog cannot display in the catalog manager dialog using default mdb model.
1068225[PW integration] [Print Organizer] Send multi pages to Print Organizer cannot work properly in Project Manager  
1069548[PW Integration] [Print Manager] It cannot send all selected pages to Print Organizer from Print Manager
1072095[Balloon] It reports unwanted warning to place balloon.
1073863[Regression][From SS4][Memory leak]Running VBA script will reproduce memory leak that related with traversing selection sets.
1090363[PW Integration] [Project Management] It should update message dialog when user has Read permission about ect.fid file with Project Management commands
1090415It should popup friendly warning dialog instead of the error dialog when open the copied page.
1092398[Update Page]It popups error dialog when clicking the Update Page menu.
1093155[Project Manager][Print Organizer]  It cannot print multi pages that located in subfolders from Print Organizer
1098657[New page] Create new page reports error in user projects
1098714[Update page]Copy two pages to a destination project with the Drawing name=[Page Number], it popups error dialog when updating the two pages together.
1098776[Update Page]Copy a page from source project to destination project, user need to update page two times, it can display the correct symbol cross reference info.
1100289[New Project] The project tree is easy missing if we New Project several times continuously.
1116799[BOM Manager] Navigate some devices in BOM Manager reports error
1122897[Page Management][page pending] It cannot show page pending status correctly after modify Drawingset/Installation/Location descriptions value
1124804[Import Drawings]The page descriptions/drawing set/Installation/Location cannot be imported using import drawings feature.
1126834[Audit test] Audit Test failed with some issues in Substation U15 10.15.00.21.
1147046[Copy Page][Balloon Number]Modify balloon number for one object, the balloon number in other attached view cannot be updated in time in the copied construction drawing.
1151888[Update Page]Update a page in a demo project, the balloon number in the page is removed.
1152950[iModelHub]No Publish Project to Server button
1153762[Update Page] Internal Error Cannot insert duplicate key row in object 'dbo.DrawingSet'
1170737Support old projects & pages only for Page level information
1171948[Balloon Callout] new user function to synchronize balloon callout symbols with active Project DB
1172280 [Copyright] Copyrights should be updated for 2023
1173414[Launch Substation] Launching Substation build 10.15.00.29 reports error because of Axlnterop.SHDocVw.dll.
1174721[Copy Circuit][Wire Number] An error occurs when copying a circuit with wire number
1176464[Import Drawing][PW]It popups error dialog when import drawings connect with PW.
1177381[Performance][Restore Project] It costs about 10 hours to restore user project with PW.
1181258[New Page_ATP]Create a new mode in Mode Manager and find it's not available in New Page 
1181275[Duplicated Devices][EDC] after user select invalid SubID Internal Error appears 'Sequence contains no elements'
1183433[Update Page]Copy the pages to destination project, then update pages, the balloon callouts in the construction drawing are all missing, and all the balloon numbers are all missing too.
1187005[Duplicated Devices][EDC] after user selects No option only display valid records for selection
1187031[Duplicated Devices][EDC] after user selects Detail option display all placed symbol and SubID records for device
1188248[ProjectWise Explorer] Cannot rename project from ProjectWise Explorer side.
1197547[Restore Project] An error occurs when restoring the project SR_DS_CS01015_A1_MICROSTATION.Prj 
1198469[Catalog Manager] Import catalog issue from 7z format
1200825[Import Drawings] incorrect page scale
1201728[Duplicate Devices]Click Details button, change the Dialog Title to “Device List”.
1202648[Duplicate Device]Click No button in the duplicate device EDC dialog, select the SubID3, but actually the symbol is assigned the SubID2.
1202943Crash during running Project Publisher with sample project ‘SAMPLE- WASHER’.