OpenUtilities Wiki Open Run Reports Faster
    • Sign in
    • +OpenUtilities
    • +Bentley sisHYD Multi Utility
    • Design Features - promis.e Functionality - Promis.e Standard
    • +OpenUtilities Substation
    • Promis.e Paths
    • -Promis.e Wiki
      • +CONNECT Edition - Promis.e
      • About Promis.e
      • +Administration Features - Promis.e
      • +APIs_VBA - Promis.e
      • +Automation Features - Promis.e
      • +Component Features - Promis.e
      • +Component Management - Promis.e
      • +CONNECT Services - Promis.e
      • +Data Manager - Promis.e
      • +Database Platform Support - Promis.e
      • +Display - Promis.e
      • +Drawing Management - Promis.e
      • +Engineering Design Considerations - Promis.e
      • Error - Object reference...General
      • +Find_Replace - Promis.e
      • Finding the Tutorial
      • +Installation_Configuration - Promis.e
      • +Interoperability - Promis.e
      • +Licensing - Promis.e
      • +Maintenance Features - Promis.e
      • +Migration - Promis.e
      • +OS Support - Promis.e
      • +Panel Layout - Promis.e
      • +Performance - Promis.e
      • +PowerPlatform Support - Promis.e
      • +Print_Publish Features - Promis.e
      • +ProjectWise Integration - Promis.e
      • Promis.e Help file
      • -Reports_Output Features - Promis.e
        • +Graphical Plan - Reports_Output Features - Promis.e
        • Red insertion point arrows visible on exported DWG
        • -Reporting - Reports_Output Features - Promis.e
          • Error - No active project to generate report
          • Error on Run Reports - DevExpress, UseNativeFormat
          • Error on Run Reports - No template selected
          • Export PLC I/O Text
          • Filter a Cable Report
          • Open Run Reports Faster
          • Panduit Labels
          • Run Reports
        • +Wiring Diagram - Reports_Output Features - Promis.e
      • +Template Management - Promis.e
      • +Text Tools - Promis.e
      • Training FAQs
      • +Wire Numbering - Promis.e
      • +Wiring Features - Promis.e
      • +Project Management - Promis.e
      • Promis.e Title
      • Working from home with Promise.e
    • Replace Family - Find_Replace - Promis.e
    • SQL Server Login

     
     Questions about this article, topic, or product? Click here. 

    Open Run Reports Faster

      Product(s): Promis.e, Bentley Substation
      Version(s): 08.11.07.xx - 08.11.13.140
      Environment: N/A
      Area: Reports_Output Features
      Subarea: Reporting

    Background

    Unused report templates can be removed from the list on Run Reports. Doing so will also reduce the amount of time it takes for the Run Reports dialog to appear as the software will have to scan through fewer report template files in order to categorize them.

    Steps to Accomplish

    1. Open the Setup dialog and find the System Paths tab or area.
    2. If the "system path management method" is set to "Manage Data Folder Path", note the folder specified for the Data folder path.  The report template folder will be the "\Templates\Reports" subfolder of this folder. 

      If the "system path management method" is set to "Manage Individual Paths", note the folder specified for the Templates path.  The report template folder will be the "\Reports" subfolder of this folder.
    3. Use Windows Explorer to copy the report template folder determined in step 1.  Rename the copy of the folder to "Reports Backup"

    4. Use Windows Explorer to open the report template folder determined in step 1.

    5. Delete any report template that is never used.  Report template files will have a .rpt extension.  For example, users that only use the ANSI-IEEE standard could delete all the "- Drawing (metric).rpt" files.  Similarly, IEC-only users could delete all the "- Drawing (inch).rpt" files.  If reports are only printed to Letter size sheets, delete the "- A4.rpt" templates. 

    If a deleted report template is later found to be needed, simply copy the corresponding .rpt file from the "Reports Backup" folder to the report template path.

      Original Author: Matt_P

    Keywords: remove, delete, unwanted, unused, slow, long, performance

    • promis.e
    • Reports_Output Features
    • performance
    • how to
    • Bentley Substation
    • en
    • Tips & Tricks
    • Reporting
    • Run Reports
    • Share
    • History
    • More
    • Cancel
    • Matt_P Created by Communities MVP Matt_P
    • When: Fri, Mar 29 2013 2:33 PM
    • Matt_P Last revision by Communities MVP Matt_P
    • When: Thu, Jan 25 2018 10:46 AM
    • Revisions: 8
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies