<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Error at Startup - Operation must use an updateable query</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Error at Startup - Operation must use an updateable query</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query</link><pubDate>Thu, 16 Apr 2020 13:31:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:23022765-c532-477b-86b2-ea304beb6b86</guid><dc:creator>Satish Saptasagar</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query#comments</comments><description>Current Revision posted to OpenUtilities Wiki by Satish Saptasagar on 4/16/2020 1:31:26 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Promis.e, Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.12.137&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Installation_Configuration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Error or Warning Message&lt;/h1&gt;
&lt;p&gt;&amp;quot;Operation must use an updateable query&amp;quot; error message displays at startup, after which none of the Promis.e/Substation tools function.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;Internal Error&lt;/strong&gt;&lt;br /&gt;Error Message: Operation must use an updateable query.&lt;br /&gt;TargetSite: Void ExecuteSQL(Int32, System.String)&lt;br /&gt;DeclaringType: MDBProxy.ConnectionManager&lt;br /&gt;Attributes: internal&lt;br /&gt;MemberType: Method&lt;/p&gt;
&lt;h1&gt;Explanation&lt;/h1&gt;
&lt;p&gt;This error usually indicates the user does not have the required permissions for one of the Access type (.mdb) databases the software is configured to use, or for the folder containing said file.&lt;/p&gt;
&lt;p&gt;When this error occurs at startup the problem is typically with the Mutli_Language_UI.mdb file, or the parts database file (if using a .mdb parts database), or the &amp;quot;\[[promis-e Data folder|promis-e Data]]\Databases&amp;quot; or &amp;quot;\[[Substation Data folder|Substation Data]]\Databases&amp;quot; folder itself.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;Check the user&amp;#39;s permissions for the paths and files the software is configured to use. This may require looking at the setup.xml file since the &lt;strong&gt;[[Setup]]&lt;/strong&gt; dialog cannot be accessed after the error occurs. Earlier versions of the software required Read/Write/Modify permissions on the folders. Since promis.e V8i SELECTseries 1, the Data folder can be set to Read-Only. However, explicitly denying write permissions or possibly using other permission scenarios can lead to the error message.&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, error message, Bentley Substation, en, Installation_Configuration&lt;/div&gt;
</description></item><item><title>Error at Startup - Operation must use an updateable query</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query/revision/8</link><pubDate>Mon, 26 Mar 2018 19:34:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:23022765-c532-477b-86b2-ea304beb6b86</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query#comments</comments><description>Revision 8 posted to OpenUtilities Wiki by Matt_P on 3/26/2018 7:34:16 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Promis.e, Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.12.137&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Installation_Configuration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Error or Warning Message&lt;/h1&gt;
&lt;p&gt;&amp;quot;Operation must use an updateable query&amp;quot; error message displays at startup, after which none of the Promis.e/Substation tools function.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;Internal Error&lt;/strong&gt;&lt;br /&gt;Error Message: Operation must use an updateable query.&lt;br /&gt;TargetSite: Void ExecuteSQL(Int32, System.String)&lt;br /&gt;DeclaringType: MDBProxy.ConnectionManager&lt;br /&gt;Attributes: internal&lt;br /&gt;MemberType: Method&lt;/p&gt;
&lt;h1&gt;Explanation&lt;/h1&gt;
&lt;p&gt;This error usually indicates the user does not have the required permissions for one of the Access type (.mdb) databases the software is configured to use, or for the folder containing said file.&lt;/p&gt;
&lt;p&gt;When this error occurs at startup the problem is typically with the Mutli_Language_UI.mdb file, or the parts database file (if using a .mdb parts database), or the &amp;quot;\[[promis-e Data folder|promis-e Data]]\Databases&amp;quot; or &amp;quot;\[[Substation Data folder|Substation Data]]\Databases&amp;quot; folder itself.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;Check the user&amp;#39;s permissions for the paths and files the software is configured to use. This may require looking at the setup.xml file since the &lt;strong&gt;[[Setup]]&lt;/strong&gt; dialog cannot be accessed after the error occurs. Earlier versions of the software required Read/Write/Modify permissions on the folders. Since promis.e V8i SELECTseries 1, the Data folder can be set to Read-Only. However, explicitly denying write permissions or possibly using other permission scenarios can lead to the error message.&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, error message, Bentley Substation, en, Installation_Configuration&lt;/div&gt;
</description></item><item><title>Error at Startup - Operation must use an updateable query</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query/revision/7</link><pubDate>Thu, 04 Aug 2016 16:06:42 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:23022765-c532-477b-86b2-ea304beb6b86</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query#comments</comments><description>Revision 7 posted to OpenUtilities Wiki by Matt_P on 8/4/2016 4:06:42 PM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;promis.e, Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.12.xx&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Installation/Configuration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Error or Warning Message&lt;/h1&gt;
&lt;p&gt;&amp;quot;Operation must use an updateable query&amp;quot; error message displays at startup, after which none of the promis.e/Substation tools function.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;Internal Error&lt;/strong&gt;&lt;br /&gt;Error Message: Operation must use an updateable query.&lt;br /&gt;TargetSite: Void ExecuteSQL(Int32, System.String)&lt;br /&gt;DeclaringType: MDBProxy.ConnectionManager&lt;br /&gt;Attributes: internal&lt;br /&gt;MemberType: Method&lt;/p&gt;
&lt;h1&gt;Explanation&lt;/h1&gt;
&lt;p&gt;This error usually indicates the user does not have the required permissions for one of the Access type (.mdb) databases the software is configured to use, or for the folder containing said file.&lt;/p&gt;
&lt;p&gt;When this error occurs at startup the problem is typically with the Mutli_Language_UI.mdb file, the parts database file (if using a .mdb parts database), or the &amp;quot;\[[promis-e Data folder|promis-e Data]]\Databases&amp;quot; or &amp;quot;\[[Substation Data folder|Substation Data]]\Databases&amp;quot; folder itself.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;Check the user&amp;#39;s permissions for the paths and files the software is configured to use. This may require looking at the setup.xml file since the [[Setup]] dialog cannot be accessed after the error occurs. Earlier versions of the software required Read/Write/Modify permissions on the folders. Since promis.e V8i SELECTseries 1, the Data folder can be set to Read-Only. However, explicitly denying write permissions or possibly using other permissions scenarios can lead to the error.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img style="border-width:0px;" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" alt=" " width="189" height="60" /&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Matt_P&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, error message, Installation/Configuration, Bentley Substation, en, SELECTsupport&lt;/div&gt;
</description></item><item><title>Error at Startup - Operation must use an updateable query</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query/revision/6</link><pubDate>Tue, 15 Dec 2015 21:41:22 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:23022765-c532-477b-86b2-ea304beb6b86</guid><dc:creator>Tani_S</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query#comments</comments><description>Revision 6 posted to OpenUtilities Wiki by Tani_S on 12/15/2015 9:41:22 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" alt=" " height="60" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;promis.e, Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.12.xx&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Installation/Configuration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;a href="/members/matt_5f00_p/default.aspx"&gt;Matt_P&lt;/a&gt;, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Error or Warning Message&lt;/h1&gt;
&lt;p&gt;&amp;quot;Operation must use an updateable query&amp;quot; error message displays at startup, after which none of the promis&amp;bull;e/Substation tools function.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;Internal Error&lt;/strong&gt;&lt;br /&gt;Error Message: Operation must use an updateable query.&lt;br /&gt;TargetSite: Void ExecuteSQL(Int32, System.String)&lt;br /&gt;DeclaringType: MDBProxy.ConnectionManager&lt;br /&gt;Attributes: internal&lt;br /&gt;MemberType: Method&lt;/p&gt;
&lt;h1&gt;Explanation&lt;/h1&gt;
&lt;p&gt;This error usually indicates the user does not have the required permissions for one of the Access type (.mdb) databases the software is configured to use, or for the folder containing said file.&lt;/p&gt;
&lt;p&gt;When this error occurs at startup the problem is typically with the Mutli_Language_UI.mdb file, the parts database file (if using a .mdb parts database), or the &amp;quot;\[[promis-e Data folder|promis-e Data]]\Databases&amp;quot; or &amp;quot;\[[Substation Data folder|Substation Data]]\Databases&amp;quot; folder itself.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;Check the user&amp;#39;s permissions for the paths and files the software is configured to use. This may require looking at the setup.xml file since the [[Setup]] dialog cannot be accessed after the error occurs. Earlier versions of the software required Read/Write/Modify permissions on the folders. Since promis.e V8i SELECTseries 1, the Data folder can be set to Read-Only. However, explicitly denying write permissions or possibly using other permissions scenarios can lead to the error.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, error message, Installation/Configuration, Bentley Substation, SELECTsupport&lt;/div&gt;
</description></item><item><title>Error - Operation must use an updateable query</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query/revision/5</link><pubDate>Thu, 22 Jan 2015 20:15:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:23022765-c532-477b-86b2-ea304beb6b86</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query#comments</comments><description>Revision 5 posted to OpenUtilities Wiki by Matt_P on 1/22/2015 8:15:15 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" alt=" " height="60" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;promis.e, Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.12.xx&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Installation/Configuration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;a href="/members/matt_5f00_p/default.aspx"&gt;Matt_P&lt;/a&gt;, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Error or Warning Message&lt;/h1&gt;
&lt;p&gt;&amp;quot;Operation must use an updateable query&amp;quot; error message displays at startup, after which none of the promis&amp;bull;e/Substation tools function.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;Internal Error&lt;/strong&gt;&lt;br /&gt;Error Message: Operation must use an updateable query.&lt;br /&gt;TargetSite: Void ExecuteSQL(Int32, System.String)&lt;br /&gt;DeclaringType: MDBProxy.ConnectionManager&lt;br /&gt;Attributes: internal&lt;br /&gt;MemberType: Method&lt;/p&gt;
&lt;h1&gt;Explanation&lt;/h1&gt;
&lt;p&gt;This error usually indicates the user does not have the required permissions for one of the Access type (.mdb) databases the software is configured to use, or for the folder containing said file.&lt;/p&gt;
&lt;p&gt;When this error occurs at startup the problem is typically with the Mutli_Language_UI.mdb file, the parts database file (if using a .mdb parts database), or the &amp;quot;\[[promis-e Data folder|promis-e Data]]\Databases&amp;quot; or &amp;quot;\[[Substation Data folder|Substation Data]]\Databases&amp;quot; folder itself.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;Check the user&amp;#39;s permissions for the paths and files the software is configured to use. This may require looking at the setup.xml file since the [[Setup]] dialog cannot be accessed after the error occurs. Earlier versions of the software required Read/Write/Modify permissions on the folders. Since promis.e V8i SELECTseries 1, the Data folder can be set to Read-Only. However, explicitly denying write permissions or possibly using other permissions scenarios can lead to the error.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, error message, Installation/Configuration, Bentley Substation, SELECTsupport&lt;/div&gt;
</description></item><item><title>Error - Operation must use an updateable query</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query/revision/4</link><pubDate>Wed, 05 Feb 2014 04:55:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:23022765-c532-477b-86b2-ea304beb6b86</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query#comments</comments><description>Revision 4 posted to OpenUtilities Wiki by Matt_P on 2/5/2014 4:55:15 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;promis.e, Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.12.xx&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Installation/Configuration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;a href="/members/matt_5f00_p/default.aspx"&gt;Matt_P&lt;/a&gt;, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;Error or Warning Message&lt;/h1&gt;
&lt;p&gt;&amp;quot;Operation must use an updateable query&amp;quot; error message displays at startup, after which none of the promis&amp;bull;e/Substation tools function.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;br /&gt;Internal Error&lt;br /&gt;----------------------&lt;br /&gt;Error Message: Operation must use an updateable query.&lt;br /&gt;TargetSite: Void ExecuteSQL(Int32, System.String)&lt;br /&gt;DeclaringType: MDBProxy.ConnectionManager&lt;br /&gt;Attributes: internal&lt;br /&gt;MemberType: Method&lt;/p&gt;
&lt;h1&gt;Explanation&lt;/h1&gt;
&lt;p&gt;This error usually indicates the user does not have the required permissions for one of the Access type (.mdb) databases the software is configured to use, or for the folder containing said file.&lt;/p&gt;
&lt;p&gt;When this error occurs at startup the problem is typically with the Mutli_Language_UI.mdb file, the parts database file (if using a .mdb parts database), or the &amp;quot;\[[promis-e Data folder|promis-e Data]]\Databases&amp;quot; or &amp;quot;\[[Substation Data folder|Substation Data]]\Databases&amp;quot; folder itself.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;Check the user&amp;#39;s permissions for the paths and files the software is configured to use. This may require looking at the setup.xml file since the [[Setup]] dialog cannot be accessed after the error occurs. Earlier versions of the software required Read/Write/Modify permissions on the folders. Since promis.e V8i SELECTseries 1, the Data folder can be set to Read-Only. However, explicitly denying write permissions or possibly using other permissions scenarios can lead to the error.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, error message, Installation/Configuration, Bentley Substation, SELECTsupport&lt;/div&gt;
</description></item><item><title>Error - Operation must use an updateable query</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query/revision/3</link><pubDate>Wed, 05 Feb 2014 04:54:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:23022765-c532-477b-86b2-ea304beb6b86</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query#comments</comments><description>Revision 3 posted to OpenUtilities Wiki by Matt_P on 2/5/2014 4:54:16 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;promis.e, Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;through 08.11.12.xx&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Installation/Configuration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;a href="/members/matt_5f00_p/default.aspx"&gt;Matt_P&lt;/a&gt;, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;Error or Warning Message&lt;/h1&gt;
&lt;p&gt;&amp;quot;Operation must use an updateable query&amp;quot; error message displays at startup, after which none of the promis&amp;bull;e/Substation tools function.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;br /&gt;Internal Error&lt;br /&gt;----------------------&lt;br /&gt;Error Message: Operation must use an updateable query.&lt;br /&gt;TargetSite: Void ExecuteSQL(Int32, System.String)&lt;br /&gt;DeclaringType: MDBProxy.ConnectionManager&lt;br /&gt;Attributes: internal&lt;br /&gt;MemberType: Method&lt;/p&gt;
&lt;h1&gt;Explanation&lt;/h1&gt;
&lt;p&gt;This error usually indicates the user does not have the required permissions for one of the Access type (.mdb) databases the software is configured to use, or for the folder containing said file.&lt;/p&gt;
&lt;p&gt;When this error occurs at startup the problem is typically with the Mutli_Language_UI.mdb file, the parts database file (if using a .mdb parts database), or the &amp;quot;\[[promis-e Data folder|promis-e Data]]\Databases&amp;quot; or &amp;quot;\[[Substation Data folder|Substation Data]]\Databases&amp;quot; folder itself.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;Check the user&amp;#39;s permissions for the paths and files the software is configured to use. This may require looking at the setup.xml file since the [[Setup]] dialog cannot be accessed after the error occurs. Earlier versions of the software required &lt;br /&gt;Read/Write/Modify permissions on the folders. Since promis.e V8i SELECTseries 1, the Data folder can be set to Read-Only. However, explicitly denying write permissions or possibly using other permissions scenarios can lead to the error.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: promis.e, error message, Installation/Configuration, Bentley Substation, SELECTsupport&lt;/div&gt;
</description></item><item><title>Error - Operation must use an updateable query</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query/revision/2</link><pubDate>Thu, 08 Aug 2013 15:48:06 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:23022765-c532-477b-86b2-ea304beb6b86</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query#comments</comments><description>Revision 2 posted to OpenUtilities Wiki by Matt_P on 8/8/2013 3:48:06 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" height="60" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;promis.e, Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.xx.xx&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Software Installation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;a href="/members/matt_5f00_p/default.aspx"&gt;Matt_P&lt;/a&gt;, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;Error or Warning Message&lt;/h1&gt;
&lt;p&gt;&amp;quot;Operation must use an updateable query&amp;quot; error message displays at startup, after which none of the promis&amp;bull;e/Substation tools function.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;br /&gt;Internal Error&lt;br /&gt;----------------------&lt;br /&gt;Error Message: Operation must use an updateable query.&lt;br /&gt;TargetSite: Void ExecuteSQL(Int32, System.String)&lt;br /&gt;DeclaringType: MDBProxy.ConnectionManager&lt;br /&gt;Attributes: internal&lt;br /&gt;MemberType: Method&lt;/p&gt;
&lt;h1&gt;Explanation&lt;/h1&gt;
&lt;p&gt;This error usually indicates the user does not have the required permissions for one of the Access type (.mdb) databases promis.e is configured to use or the containing folder. When this error occurs at startup the problem is typically with the Mutli_Language_UI.mdb file, the parts database file (if using a .mdb parts database), or the &amp;quot;\promis-e Data\Databases&amp;quot; folder itself.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;Check the user&amp;#39;s permissions for the paths and files promis.e is configured to use. This may require looking at the setup.xml file since the Setup dialog cannot be accessed after the error occurs. Earlier versions of promis.e required &lt;br /&gt;Read/Write/Modify permissions on the folders. Since promis.e V8i SELECTseries 1, the Data folder can be set to Read-Only. However, explicitly denying write permissions or possibly using other permissions scenarios can lead to this error.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;[[SELECTsupport TechNotes and FAQs]]&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Software Installation, promis.e, error message, Bentley Substation, SELECTsupport&lt;/div&gt;
</description></item><item><title>"Operation must use an updateable query" error at startup</title><link>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query/revision/1</link><pubDate>Fri, 02 Aug 2013 16:34:41 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:23022765-c532-477b-86b2-ea304beb6b86</guid><dc:creator>Matt_P</dc:creator><comments>https://communities.bentley.com/products/utility_network_analysis___design/w/utility_network_analysis_and_design_wiki/7801/error-at-startup---operation-must-use-an-updateable-query#comments</comments><description>Revision 1 posted to OpenUtilities Wiki by Matt_P on 8/2/2013 4:34:41 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;promis.e, Bentley Substation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.xx.xx&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Software Installation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;a href="/members/matt_5f00_p/default.aspx"&gt;Matt_P&lt;/a&gt;, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;Error or Warning Message&lt;/h1&gt;
&lt;p&gt;&amp;quot;Operation must use an updateable query&amp;quot; error message displays at startup, after which none of the promis&amp;bull;e/Substation tools function.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;br /&gt;Internal Error&lt;br /&gt;----------------------&lt;br /&gt;Error Message: Operation must use an updateable query.&lt;br /&gt;TargetSite: Void ExecuteSQL(Int32, System.String)&lt;br /&gt;DeclaringType: MDBProxy.ConnectionManager&lt;br /&gt;Attributes: internal&lt;br /&gt;MemberType: Method&lt;/p&gt;
&lt;h1&gt;Explanation&lt;/h1&gt;
&lt;p&gt;This error usually indicates the user does not have the required permissions for one of the Access type (.mdb) databases promis.e is configured to use or the containing folder. When this error occurs at startup the problem is typically with the Mutli_Language_UI.mdb file, the parts database file (if using a .mdb parts database), or the &amp;quot;\promis-e Data\Databases&amp;quot; folder itself.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;Check the user&amp;#39;s permissions for the paths and files promis.e is configured to use. This may require looking at the setup.xml file since the Setup dialog cannot be accessed after the error occurs. Earlier versions of promis.e required &lt;br /&gt;Read/Write/Modify permissions on the folders. Since promis.e V8i SELECTseries 1, the Data folder can be set to Read-Only. However, explicitly denying write permissions or possibly using other permissions scenarios can lead to this error.&lt;/p&gt;