Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
OpenUtilities
OpenUtilities Wiki
OpenUtilities
Sign In
All tags
Bentley Substation
Component Management
Accessory Kit Manager
Administration Features
Catalog Management
Catalog Manager
Component Features
CONNECT Edition
Create Symbol
en
error message
Family Creation
Getting Started
how to
Insert Symbol By ID
Insert Symbol By Name
Insert Symbol By Part Number
Installation_Configuration
Menu
Migrated
parts database
Problem Solving
promis.e
SELECTsupport
Setup
Tips & Tricks
v8i
Restore Project or Import Catalog always appears at start up
Matt_P
Product(s): Bentley Substation Version(s): 08.11.12.xx Environment: N/A Area: Project Management Subarea: Backup and Restore Project Problem Description A Restore Project or Import Catalog…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Error - Physical file does not exist, Insert Symbol
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Component Features Subarea: Insert Symbol By Name Error or Warning Message When trying to insert…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Creating symbols from 3D models
Matt_P
Product(s): Bentley Substation, Promis.e Version(s): through 10.00.00.232 Environment: N\A Area: Component Management Subarea: Create Symbol I have some files of equipment that I downloaded from…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Accessory kits are empty
Matt_P
Product(s): Bentley Substation Version(s): through 10.00.00.232 Environment: N\A Area: Component Management Subarea: Accessory Kit Manager Problem Description When I open Accessory Kits Manager…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Accessory kits missing from Accessory Kits Manager
Sarvesh Kulkarni
Product(s): Bentley Substation Version(s): through 10.00.00.232 Environment: N\A Area: Component Management Subarea: Accessory Kit Manager Problem Description When I open Accessory Kits Manager…
over 4 years ago
OpenUtilities
OpenUtilities Wiki
Accessory Kits Manager
Avanti Khandalkar
Product(s): Bentley Substation Version(s): through 10.00.00.232 Environment: N\A Area: Component Management Subarea: Accessory Kit Manager Background Accessory Kits Manager is used to create…
over 4 years ago
OpenUtilities
OpenUtilities Wiki
Unmapped fields cannot be moved on Parts Database Manager Customization
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.12.xx Environment: N/A Area: Component Management Subarea: Parts Database Problem Description After mapping fields such as…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Representing a bus bar on schematics
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Wiring Features Subarea: N/A How to represent bus bars on schematics in Promis.e? Background…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Family modifications not reflected in project
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Component Management Subarea: Family Creation Problem Description Why are the changes I made…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Error creating part database path, DBNETLIB
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): 08.11.07.82 Environment: N\A Area: Administration Features Subarea: Setup Error or Warning Message When the Finish button is clicked when…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Error-Data at the root level is invalid. Line 1,Position 1.
Satish Saptasagar
Product(s): Promis.e, Bentley Substation Version(s): 08.11.12.xxx Environment: N/A Area: Installation_Configuration Subarea: N/A Error or Warning Message Internal Error Error Message: Data…
over 3 years ago
OpenUtilities
OpenUtilities Wiki
Error - "database is used by another user" when creating parts database path
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.12.xx Environment: N/A Area: Administration Features Subarea: Setup Error or Warning Message During the creation of a parts…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Empty rows on Select Part Number
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.12.xx Environment: N/A Area: Component Features Subarea: Edit Components Problem Description When trying to assign a part…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Assign part numbers to a symbol definition
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Component Management Subarea: Create Symbol How to assign part numbers to a symbol in Create Symbol…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Error - Some connection point text is invalid
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 10.01.00.23 Environment: N/A Area: Component Features Subarea: Edit Components Error or Warning Message When trying to change connection…
over 4 years ago
OpenUtilities
OpenUtilities Wiki
Create Family
Matt_P
Product(s): promis.e, Bentley Substation Version(s): through 08.11.13.57 Environment: N/A Area: Component Management Subarea: Family Creation Background The Create Family tool is used to create…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Wire link cross reference column direction
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Wiring Features Subarea: Insert Wire Link How do I control whether the column of cross references…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Error inserting symbols - Record is deleted
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.12.137 Environment: N/A Area: Component Features Subarea: Insert Symbol By Name Error or Warning Message The following error…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Symbol preview appears zoomed far out
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Component Management Subarea: Catalog Manager Problem Description In Catalog Manager and on…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Error inserting symbols - The symbol mismatched between drawing file and the catalog.mdb
Jesse Dringoli
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Component Features Subarea: Insert Symbol By Name Error or Warning Message When trying to insert…
over 3 years ago
OpenUtilities
OpenUtilities Wiki
Wrong part numbers listed in Select Part Number
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): 08.11.xx.xx Environment: N/A Area: Component Management Subarea: Parts Database Problem Description When assigning a part number to a device…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Specify multiple symbols for one mode in a part number record
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N\A Area: Component Management Subarea: Parts Database Sometimes I use a certain symbol for a device in…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
Quickly Navigate To Part Number Records in Promis.e Connect
Avanti Khandalkar
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Component Management Subarea: Parts Database Background Quickly bring up the record for a part…
over 2 years ago
OpenUtilities
OpenUtilities Wiki
Error inserting symbol - Query is too complex
Jesse Dringoli
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.12.137 Environment: N/A Area: Component Features Subarea: Insert Symbol By Name Error or Warning Message A "Query is too complex…
over 3 years ago
OpenUtilities
OpenUtilities Wiki
Error - Object reference...CheckField on Parts Database Manager
Matt_P
Product(s): Promis.e, Bentley Substation Version(s): 08.11.xx.xx Environment: N\A Area: Component Management Subarea: Parts Database Error or Warning Message When trying to add or modify a…
over 5 years ago
OpenUtilities
OpenUtilities Wiki
View related content throughout OpenUtilities
More
Cancel
>