Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenUtilities
  • Product Communities
OpenUtilities
OpenUtilities Wiki OpenUtilities
    • Sign In
    • All tags
    • how to
    • Options
    • Add Wire Label
    • Administration Features
    • Administrative Features
    • Automatic Wire Numbering
    • Bentley Substation
    • Component Features
    • Component Management
    • Create Symbol
    • Device Cross Referencing
    • Draw Wire
    • en
    • Getting Started
    • Language Phrases
    • Migrated
    • Modify Wire Label
    • OpenUtilities Substation
    • Printing_Plotting
    • promis.e
    • Promis.e CONNECT Edition
    • promise CONNECT
    • Reports_Output Features
    • SELECTsupport
    • wire numbering
    • Wiring Features
    • Wiring Manager
    • How to change the Prefix for a Device Cross Reference - Promis.e CONNECT

      Satish Saptasagar
      Satish Saptasagar
      Product(s): Promis.e CONNECT Edition Version(s): 10.00.XX.XX to 10.08.XX.XX Environment: NA Area: Component Feature Subarea: Device Cross-Reference Background: Users might need to change…
      • over 2 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • How to make Wire Gauges & Color appear with Wire Number in OpenUtilities Substation CONNECT

      Satish Saptasagar
      Satish Saptasagar
      Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.00.XX.XX to 10.09.XX.XX Environment: NA Area: Administration Features Subarea: Options Background: This article will help…
      • over 2 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • How to make Wire Gauges & Color appear with Wire Number in Promis.e CONNECT

      Satish Saptasagar
      Satish Saptasagar
      Product(s): Promise CONNECT Edition Version(s): 10.00.XX.XX to 10.06.XX.XX Environment: NA Area: Administration Features Subarea: Options Background: This article will help users to make…
      • over 2 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • How to Specify Default Text Settings for Symbol - OpenUtilities Substation

      Satish Saptasagar
      Satish Saptasagar
      Product(s): OpenUtilities Substation CONNECT Edition Version(s): 10.00.XX.XX to 10.09.XX.XX Environment: NA Area: Component Management Subarea: Create Symbol Background: The default text…
      • over 2 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • How to Specify Default Text Settings for Symbol

      Satish Saptasagar
      Satish Saptasagar
      Product(s): Promis.e CONNECt Edition Version(s): 10.00.XX.XX to 10.06.XX.XX Environment: NA Area: Component Management Subarea: Create Symbol Background: The default text settings for symbol…
      • over 2 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • How to change Company Name and Address on Title Block

      Satish Saptasagar
      Satish Saptasagar
      Product(s): Promis.e CONNECT Edition Version(s): 10.00.XX.XX to 10.06.XX.XX Environment: NA Area: Administration Features Subarea: Options Background: While working on multiple customer Projects…
      • over 2 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Add a Language Phrase to Symbol or I/O Text

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Text Tools Subarea: Language Phrases How to use Language Phrases in symbol and I/O text? Background…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Wire Tag Installation and Location Fields

      Matt_P
      Matt_P
      Product(s): Promis.e, Substation Version(s): through 08.11.13.140 Environment: N/A Area: Wire Numbering Subarea: Automatic Wire Numbering How do you use the Installation and Location fields on…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • ProjectWise Project Level Variables

      Matt_P
      Matt_P
      Product(s): Bentley Substation & promis.e Version(s): 08.11.XX.XX Environment: N/A Area: Platform Support Subarea: ProjectWise Integration Background Adding and mapping page level variables…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Cable conductor text appearance on cable diagrams and cross reference symbols

      Jesse Dringoli
      Jesse Dringoli
      Product(s): Promis.e, Bentley Substation Version(s): 08.11.13.96 Environment: N\A Area: Administration Features Subarea: Options How can I control the appearance of the cable conductor text on…
      • over 3 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Resize or disable capture tolerance boxes

      Jesse Dringoli
      Jesse Dringoli
      Product(s): Promis.e, Bentley Substation Version(s): 08.11.10 - 08.11.13.73 Environment: N\A Area: Administrative Features Subarea: Options How do I change the size of the red boxes that appear…
      • over 3 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Specify default text settings for Create Symbol

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.73 Environment: N/A Area: Component Management Subarea: Create Symbol How to set the default text styles used for device…
      • over 6 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Manage page and project description names

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Administration Features Subarea: Options How do I change or add page and project description names…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Cross reference prefix appearance

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Component Features Subarea: Device Cross Referencing What are these miniature symbols in front…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Format output of Now title block variable

      Jesse Dringoli
      Jesse Dringoli
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.73 Environment: N/A Area: Administration Features Subarea: Options After adding the Now variable to a title block using Title…
      • over 3 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Change what is displayed at wire links

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.12.140 Environment: N/A Area: Administration Features Subarea: Options How do I change what information is displayed at wire…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Make gauge and color appear with wire numbers

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Administration Features Subarea: Options How do I make gauge and color or other wire properties…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Remove the dash prefix from device tags

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Administration Features Subarea: Options Why are there dashes in front of the device tags on symbols…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Change the company name and address that appears on the title block

      Jesse Dringoli
      Jesse Dringoli
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.73 Environment: N/A Area: Administration Features Subarea: Options How do I change the company name and address that appears…
      • over 3 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Underline normally closed contacts

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Administration Features Subarea: Options How do I make cross references to normally closed (NC…
      • over 5 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • Template Project Options - V8i

      Matt_P
      Matt_P
      Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Administration Features Subarea: Options For Bentley Substation CONNECT Edition, see the Default…
      • over 4 years ago
      • OpenUtilities
      • OpenUtilities Wiki
    • View related content throughout OpenUtilities
    • More
    • Cancel
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies