DGN sheet model rotated when saving to DWG
Andrew Bell
Product: MicroStation Version: V8i, CONNECT Environment: N\A Area: DWG Subarea: Save Problem Description When I save my DGN Sheet Model which has its view rotated through 15 degrees to DWG…
over 4 years ago
MicroStation
MicroStation Wiki
Point placing Tools Update
dominic SEAH
Points to Patterns Place Active Cell has active angle and x,z,y scale as part of its dialog, but not Place Active Point which has a Cell/Character option. It would be a big improvement if the Point placing tools (Place Active Point,Place Active Point…
over 5 years ago
MicroStation
User Interface
Paste copied text @ AA=0 but text comes in upside down
Dbl J D
I copied some text to the clipboard and pasted into the file BUT it comes in upside down. The active angle is 0. I'm not sure why this is happening. Any ideas out there? Thank you
over 8 years ago
MicroStation
MicroStation Forum
RE: Is there away to rotate text to be parallel to a given line
geewizz
i think i might of found in this link, going to give it a try: communities.bentley.com/.../active-angle-assistant-macro.aspx
over 9 years ago
MicroStation
MicroStation Forum
RE: why does text invert when changing font?
Lorys
Unknown said: Using the Change Text Attributes box, I have ONLY the font box checked and select ARIAL. The selected text with change to Arial but it also rotates 180°. Can you post screen shots before and after and also have dialogs for text,…
over 6 years ago
MicroStation
MicroStation Forum
[CONNECT] Standardizing Design File Settings for New Files
Christopher Christian
Is it possible to apply the same design file setting for any new design file under the same WorkSet? I had originally thought I understood this could be achieved through the Seed file, but I have had no such luck. I also thought this could be applied…
Answered
27 days ago
MicroStation
MicroStation Forum
RE: True Scale
Dharma Rajan
Hai Chouinard, Unknown said: Could you elaborate a bit on what you are trying to accomplish? I want to place the cells using key-in(to set the properties like Active Angle,True Scale,etc.,) in the form of Sidebar menu(sbm file).
over 8 years ago
MicroStation
MicroStation Forum
Support of 400 degrees (gon, centesimal)
Elisabeth Pry
Applies To Product(s): MicroStation Version(s): 07.01.05.03 Environment: Windows 7 32 bit,Windows 7 64 bit Area: Measure Subarea: N\A Original Author…
over 9 years ago
MicroStation
MicroStation Wiki
Tab jump order in function windows doesn't work properly
f.mandoki
I use tab jumps in function windows a lot. When I perform any action I usually call the function window by CTRL + SPACE and then jump with TAB from box to box. Since CE, especially CE4 some tab jumps don't work in the correct order anymore, e.g. when…
over 5 years ago
MicroStation
MicroStation Forum
RE: Anyone have an idea how I can make a lasso leader with the origin at the center of the circle?
Lorys
Unknown said: Well after trying that out it still doesn't quite work as expected. The set item toolsettings cellinteractiontype=2 only works for me if I open the place active cell dialogue first via the button. If I open the place active cell action…
over 7 years ago
MicroStation
MicroStation Forum
RE: Inserting a cell aligned to ACS using key in commands
Lorys
there was a macro around that measured the view rotation so if you knew the view rotation you could place the cell at the view rotation angle to then be the active angle.... something like aa=x;ac=cell name then it just waits for you to place the cell…
over 8 years ago
MicroStation
MicroStation Forum
CR - add calculator function to move/copy parallel
John Cannon
Can the ability to use the calculator be added for this tool? This is the one place I need it that it isn't available. It works in Rotate for active angle and Scale for x/y scale - looking for the same functionality to calculate the distance.
over 9 years ago
MicroStation
MicroStation Forum
Re: Picking Coordinates
caddcop
In case you are asking how to input coordinates, see Precision Input Key-ins in the help. Old School: XY=[xcoord,ycoord,zcoord] Delta View (Relative to view orientation) DX=[deltaX,DeltaY,DeltaZ] Delta Design File (Ignores view rotations) …
over 9 years ago
MicroStation
MicroStation Forum
Re: How can i align a text over a line?
mwlong
Check this link. You can download Active Angle Assistant to rotate the text to the line. Then you just move the text into position. You could also use the edit text tool and copy the text then use place text and switch it to along element. http…
over 11 years ago
MicroStation
MicroStation Forum
Re: More use of Parallel Snap
peterEm
We know how to do it with AccuDraw and also the old mdl Active Angle Assistant we have used before. (working with Microstation from version 3.2 til now) only we think MicroStation works faster to use Parallel Snap on more functies.
over 10 years ago
MicroStation
MicroStation Forum
RE: Importing AutoCAD Blocks using a key in script
Phil Chouinard
Unknown said: I would like to insert an AutoCAD drawing block into a MicroStation drawing at a particular angle, but using key in commands. Based on that, you could: set the active cell (block) name set the active angle place the cell using…
over 8 years ago
MicroStation
MicroStation Forum
RE: skew command?
Jon Summers
I suggest that you attach the skewed file as a reference to an otherwise empty file. Then, rotate the reference attachment to eliminate the skew. That way, you won't compromise the skewed file by unwittingly performing some drastic action. Once you…
over 7 years ago
MicroStation
MicroStation Forum
RE: keyboard commands
George A. Martin
Here are some of the OLD 2 character key-in's that still work Element Attributes: LV= active level (working level) WT= active line weight (0-31) LC= active Line Code (0-7), custom line style name or ByLevel CO= color number/name/value (0-254) Drawing…
over 6 years ago
MicroStation
MicroStation Forum
Enabling a disabled AccuSnap
Jordan Stierly
Original Tip Date: Jul. 3, 2002 Enabling a disabled AccuSnap Some tools haven't had AccuSnap enabled on them. Take for example Place Fence , IntelliTtrim set to the Cut mode and even these old keyin commands: Active Angle…
over 13 years ago
MicroStation
[Archived] AskInga Wiki
RE: What is a "Place Text Note"?
mwlong
From the Help file within Microstation Place Text Node Place Text Nod Used to place empty text nodes in a design to be filled with text later using the Place Text tool or to be linked with a database row using the Attach Displayable Attributes…
over 5 years ago
MicroStation
MicroStation Forum
RE: View Independant Text
Andrew Bell
Generally, what I would think you would be performing is to Place Text using the method of View Independent in the design file that is being referenced and then mirrored. That way it should not matter which rotation the referenced design file is placed…
over 9 years ago
MicroStation
MicroStation Forum
Place Note
Robert Watson
how do you change the angle for place note? I've tried active angle pt2, but that didn't work (did for place text). Microstation V8i (Select series 2), v08.11.07.443 Geopak V8i (Select series 2), v 08.11.07.494 Win 7 Enterprise 64bit 8 GB
over 11 years ago
MicroStation
MicroStation Forum
Re: Text rotation
caddcop
Get the Active Angle Assistant from the Ask Inga Wiki area. It's a MVBA project (MicroStation VBA) that can be loaded and run, but also studied to learn about programming.
over 12 years ago
MicroStation
MicroStation Forum
Enhancement to the rotate tool
TWalters
The rotate tool currently has 3 possible methods: 2 Points, 3 Points, Active Angle. There really needs to be a 3rd option called Cardinal or Cardinal Angle: This would allow you to apply an absolute angle to any element relative to north. So for example…
over 8 years ago
MicroStation
MicroStation Forum
Resolved issues for MicroStation CONNECT Edition 17.2
Dan Eng
Issue Description 1045180 Fixed crash while opening specific DWG file. 1046890 Resolved crash with Item Type Filtered Picklist when used in Arrays with specific file 1052875 Resolved issue with controls from the Modify Named…