Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel

Unable to find what you are looking for? Click here

 

  • Comment Personal .UCF

    Koog
    Koog
    I am a 2.5 year user MicroStation CONNECT Edition - Version 10.16.00.80 Windows x64, Using RealDWG 2021, and Descartes Is there a way to comment in my personal .UCF file? I just saw where you use "#" at the start of each line. Maybe someone could…
    • Answered
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • Missing UCF file error when opening "...for MicroStation" shortcut

    Scott Kampa
    Scott Kampa
    Applies To Product(s): SewerGEMS, CivilStorm, WaterGEMS, WaterCAD, StormCAD, SewerCAD, PondPack Version(s): CONNECT Edition, V8i Environment: MicroStation V8i Area: Installation Original Author: Jesse…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • RE: Using upf and ucf file in PW

    Josh Miller
    Josh Miller
    THanks for the response Matt. We are currently using Microstation v8i and will eventually switching to connect.
    • over 2 years ago
    • ProjectWise
    • ProjectWise Design Integration Forum
  • RE: How to load a custom UCF at startup of Microstation CE/OpenCities Map application.

    Tuan Le
    Tuan Le
    There's some information in this blog post for UCF: communities.bentley.com/.../connect-edition---configuration-tips-user-preferences-in-onedrive-or-other-locations
    • over 2 years ago
    • Product Administration
    • Product Administration Forum
  • RE: Connect - Changing the location of the ucf file

    Rod Wing
    Rod Wing
    Mark, The only workaround I've found still doesn't allow you to store these files in a different location. MicroStation CONNECT has many new SEED variables, including one for just about every file stored in the default prefs folder. You can point…
    • over 6 years ago
    • MicroStation
    • MicroStation Forum
  • MSV8iで作成した構成変数ファイル(*.ucf)をCONNECT Editionへの移行について

    Jing.Bai
    Jing.Bai
    Product(s): MicroStation Version(s): V8i, CONNECT Environment: N\A Area: WorkSpace Subarea: General 【問題】 MicroStation V8iで作成した構成変数ファイル(*.ucfファイル)を流用したいのですが、Connect Editionではどのフォルダに格納すればよいでしょうか…
    • over 4 years ago
    • MicroStation
    • MicroStation Wiki (日本語)
  • RE: How does Microstation know where to look for the ucf?

    Jon Summers
    Jon Summers
    Adam Halls said: I'm working to better understand how workspaces function What version (e.g. v10.x.y.z) of MicroStation, or other product, are you using? MicroStation CONNECT configuration is different (better) compared to MicroStation v8 configuration…
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • [CONNECT 10.17.02] New machine, trying to get custom tools in quick access bar

    Scott Russell
    Scott Russell
    I added the dgnlib to MS_GUIDGNLIBLIST variable but it still wouldn't show up in the customizations dialogue box. Finally I opened the .ucf file and entered it manually. This ended up doing the trick. I'd like to know why this happened... is it typical…
    • 7 months ago
    • MicroStation
    • MicroStation Forum
  • RE: UPF, UCF, PCF CONFIGURATION

    Andrew Bell
    Andrew Bell
    Would you be able to supply details of the software and version so we can assist appropriately. If this is related to the configuration of workspaces in plain MicroStation V8i and relating to the networking of them then this Wiki article might be of…
    • over 6 years ago
    • Product Administration
    • Product Administration Forum
  • RE: What is the best procedure for loading a client's workspace in CONNECT?

    William Spagnoli
    William Spagnoli
    Thanks Kevin. It turned out we just needed to change some of the language in the .ucf & .pcf files that the client provided. Once we made some basic changes to where we were wanting these files to be stored and pulled from, everything eventually fell…
    • 3 months ago
    • Product Administration
    • Product Administration Forum
  • RE: ORD/CONNECT One User Preference across multiple workspaces?

    Kevin van Haaren
    Kevin van Haaren
    Yes. I'm debating adding a %include to the Personal.ucf (all of them) that will include a UCF from OneDrive, but we rarely need to add things to the ucf, our more typical usage is to clean everything out of the UCF to fix issues rather than adding things…
    • 11 months ago
    • Product Administration
    • Product Administration Forum
  • Microstation Connect - Rename personal.upf and personal.ucf

    Raphael :)
    Raphael :)
    Hi, I just switched from V8i to Connect and would have a few questions, also among to a comment in the following text (hope I can link this here?): https://envisioncad.com/microstation-connect-ucf-and-pcf-files/ - In the Connect Edition, the UPF and…
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • RE: 如何定义自己的ucf文件。

    hj z
    hj z
    ms为connect版本,在ce版本中用户配置文件都默认保存在personal.ucf文件中,我想如何创建自己的ucf文件,就如之前版本的一样,有自己的ucf,这样可以方便管理配置变量,首选项。
    • over 6 years ago
    • Bentley 中国优先社区
    • ◆ 二次开发(MicroStation编程, ProjectWise编程等)
  • RE: Setting up multiple projects and assigning .pcf and .ucf to each project.

    Soojong Oh
    Soojong Oh
    I heard that Microstation Select Series 4 has connect edition features. Do you think with SS4, you can assign .pcf and . ucf to specific projects?
    • over 6 years ago
    • MicroStation
    • MicroStation Forum
  • RE: [MicroStation v8i SS1] deleting elements connected to the base

    Mateusz Czajkowski
    Mateusz Czajkowski
    for others, changing the value in msgeo.cfg to the following resolved the problem: #---------------------------------------------------------------------------------------- # # $RCSfile: msgeo.ucf,v $ # $Revision: 1.47 $ # $Date: 2008/12/10 18:00…
    • 10 months ago
    • MicroStation
    • MicroStation Forum
  • RE: Error 126 Could not load mcm.dll when opening a drawing from Projectwise after having an upgrade from V8I to Microstation connect edition

    Kevin van Haaren
    Kevin van Haaren
    What version of Connect and what version of ProjectWise? Did you verify the 2 are compatible? See the ProjectWise Version Support Matrix (bentley.com) to confirm Generally with MicroStation when one person has an issue and others don't I suspect the…
    • 9 months ago
    • ProjectWise
    • ProjectWise Design Integration Forum
  • RE: MicroStation Connect personal.ucf variable issue

    Jon Summers
    Jon Summers
    Mark Winegar said: if you modify the Personal.ucf file on the local hard drive and add a configuration variable Please show your configuration statement.
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • RE: CONNECT - Dimension by 3 points not available?

    Barry Lothian
    Barry Lothian
    All is not lost yet (well, you'll need to check for me as I dont use CE) Add this to a CFG or your UCF and try the regular Linear Dimensioning Tool (not the Dimension Element Tool) MS_DIMLEGACYPOINTORDER=1 See if that works for you However, its…
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • RE: [CONNECT] Disable Workset Verification

    Ben Davies
    Ben Davies
    Hi Marc, It doesnt work. Still throws the dialog. Unable to process files in bulk using connect its a real problem. I added the variable (its in my ucf) as shown above Ustn versions 10.14.02.01
    • over 2 years ago
    • Product Administration
    • Product Administration Forum
  • RE: [CONNECT] call a specific .src or a .dgnlib file using a batch process script

    Barry Lothian
    Barry Lothian
    Hi Damien I'm not sure why you are wanting to use the Batch Processor via the Command Line as your go to method of attack. If I understand the situation correctly, you are intending to make alterations to the files and then send them to whoever the…
    • over 1 year ago
    • MicroStation
    • MicroStation Forum
  • [ORD 2020 R3/Connect 16] Custom/network configuration vs. msconfig

    MaryB
    MaryB
    I am trying to set up our Bentley Connect Workspace onto our network. The first modification is a customized shortcut which includes the switch -wc"M:\Bentley\ORD\NetworkRedirect.cfg" This file has one statement set in it: #====================…
    • Answered
    • over 2 years ago
    • Product Administration
    • Product Administration Forum
  • RE: [CONNECT] Is it possible to set up different standards for each workset??

    Marc Thomas
    Marc Thomas
    Hi Brett, The migration wizard attempts a best fit reflecting the V8i configuration. You may be better off with a manual approach. There are Standards folders in both WorkSpace and WorkSet structures, Out of the box configurations look at both and…
    • over 2 years ago
    • Product Administration
    • Product Administration Forum
  • ProStructures CONNECT Edition Configuration

    Vyanktesh Nama
    Vyanktesh Nama
    Configuration In ProStructures CONNECT Edition configuration has undergone significant reorganization and many of the changes applied to MicroStation are applicable to ProStructures. Getting Started with Your ProStructures CONNECT Edition Configuration…
    • over 2 years ago
    • ProStructures
    • ProStructures Wiki
  • ORD 2020 R3/Connect 16 - Custom/network configuration vs. msconfig

    Carl Myhill
    Carl Myhill
    Q [ORD 2020 R3/Connect 16] Custom/network configuration vs. msconfig Offline MaryB 99.41.238.248 Mon, Aug 9 2021 7:12 PM I am trying to set up our Bentley Connect Workspace onto our network. The first modification is a customized…
    • over 2 years ago
    • Product Administration
    • Product Administration Forum
  • RE: [CONNECT Update 14 VBA] Issue with CreateDesignFile Method

    Jan Šlegr
    Jan Šlegr
    Timothy Russell said: My workspace and MS_SEEDFILES configuration variables are set up by our survey department. If there is an application, used in company, the workflow has to support it and to be configured properly. Fortunately there are more…
    • over 2 years ago
    • MicroStation Programming
    • MicroStation Programming Forum
>
Communities
  • Home
  • Getting Started
  • Community Central
  • Products
  • Support
  • Secure File Upload
  • Feedback
Support and Services
  • Home
  • Product Support
  • Downloads
  • Subscription Services Portal
Training and Learning
  • Home
  • About Bentley Institute
  • My Learning History
  • Reference Books
Social Media
  •    LinkedIn
  •    Facebook
  •    Twitter
  •    YouTube
  •    RSS Feed
  •    Email

© 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies