Browse By Tags

  • Video Brief - How do I Integrate my Bentley Plant Project with ProjectWise?

    Applies To Product(s): Project Administrator/ProjectWise Version(s): V8i Environment: Project Creation Area: ProjectWise Subarea: Integration Original Author: Brandon Moberg, Bentley Product Advantage…
  • AutoPLANT V8i (SELECTseries 6) "Refresh2" Release Announcement

    Hello, A new Refresh release for AutoPLANT V8i (SELECTseries 6) 64-bit is now available, which can be downloaded from the Bentley Software Fulfillment site. The released AutoPLANT V8i (SELECTseries 6) Refresh2 Version 08.11.11.135 products are: …
  • AutoPLANT V8i (SELECTseries 6) "Refresh" Release Announcement

    We are pleased to announce the latest release of AutoPLANT V8i (SELECTseries 6) Refresh 64-bit Version 08.11.11.121 that can be downloaded from the Bentley Software Fulfillment site: The released AutoPLANT V8i (SELECTseries 6) Refresh products are…
  • AutoPLANT V8i (SELECTseries 6) is LIVE

    AutoPLANT V8i (SELECTseries 6) - the best products for Plant Designing and Instrumentation & Wiring Layouts are now available. Please visit http://selectservices.bentley.com/ to download the latest AutoPLANT products. These are: Prerequisites and…
  • AutoPLANT - Special characters lost in PXF translation

    When exporting via PXF a pipe run from one model and importing it into another model we loose special characters in long descriptions. In the attached example, some of the pipe and elbow components have only existed in this model. Others have been imported…
  • AutoPLANT integration with ProjectWise V8i (SELECTseries 3) and 64-bit AutoCAD [TN]

    Applies To Product(s): AutoPLANT Version(s): V8i SS3 08.11.08.123 & 08.11.08.151 Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group Overview There is a known…
  • AutoPLANT on a 64 bit OS

    Installing AutoPLANT on a 64 bit OS Disclaimers : This blog is due to many requests. Although it is not officially supported, perhaps it is better we suggest how to make it work and then monitor feedback. With that said, AutoPLANT is supported and therefore…
  • AutoPLANT V8i (SELECTseries 3) Integration Module for AutoCAD 2012...

    I am pleased to announce that the above integration module is now available from SELECT downloads as below. This integration module will allow users to deploy AutoPLANT with the latest version of AutoCAD 2012. This AutoCAD 2012 integration module…
  • Problem inserting symbol after creation using Autoplant V8I 64bit

    I have followed the steps and taken the existing gate valve symbol to modify and elongate it into a different symbol. I went through the necessary steps and when I insert from symbol manager into the PID it doesn't fully trim the process lines out of…
  • AutoPLANT P&ID V8i (SELECTseries 3) (64-bit): Unhandled Exception and ADS Request Error messages when executing ASIREGENALL, creating an exchange drawings, or executing import/export block commands

    AutoPLANT P&ID V8i (SELECTseries 3) (64-bit): Unhandled Exception and ADS Request Error messages when executing ASIREGENALL, creating an exchange drawings, or executing import/export block commands To boost the performance of AutoPLANT P&ID V8i…
  • AutoPLANT V8i (SELECTseries 3) eSeminars

    Following on from the successful release of the AutoPLANT V8 i (SELECTseries 3) product suite, I am pleased to announce the eSeminar series showcasing some of the new features in the release. The series is broken into NAOU & EMEA for the moment so…
  • AutoPLANT V8i (SELECTseries 3) "Refresh" Release ReadMe's...

    The ReadMe files for the recent AutoPLANT V8i (SELECTseries 3) "Refresh" Release are now available for download from the Files section of this forum. Thanks. Chris
  • AutoPLANT SS2 & AutoCAD 2011

    The long awaited Select Sereis 2 release of AutoPLANT I know is going to be AutoCAD 2010 compatible, but with AutoCAD 2011 coming out now and it being not a major release over 2010 (2010 is R18.0, and 2011 is R18.1), will AP SS2 being AutoCAD 2011 compatible…
  • Updated AutoPLANT V8i (SELECTseries 3) ReadMe files...

    The AutoPLANT V8i (SELECTseries 3) ReadMe files, posted to the files area of this forum, have been updated. The sections that have been updated are System Requirements and Known Issues. The System Requirements ReadMe has been update to add clarity…
  • symbol manager problems in autoplant PID

    I am running windows 7, 64 bit with Autoplant SS3 V8i. I am having problems with the symbol manager. I have gone through the set up on making a custom directory and pathing the directory to the PID. I have done this by going through the document manager…