Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
AECOsim Building Designer
AECOsim BD
3D
ABD
aeco sim
AECOsim
AECOsim Building Designer Architecture
AECOsim Building Designer Mechanical
AECOsim Building Designer SS5
AECOsim Building Designer Training
AECOSIM dataset
AECOsim SS 6
aecosim ss5
AECOsim SS6
Annotation
Architecture
Bentley
Bentley AECOsim Building Designer
Bentley Architectural V8i
Bentley Architecture
Bentley Architecture BA
Bentley Architecture V8i
Building Information Modeling
Building Views
Dataset
Drawing Views
Dynamic Views
RE: IFC Export. Objects lost. Aecosim Building Designer ss3
Jose Vicente
Sorry for the late response. Attached is the file I used to test. Thanks
test06.dgn
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Slab Penetrations Tool- Problems with extractions
ED3D
The tool appears to work well in the model. Penetrations through the slab look fine and as I'd expect them to. When it comes to creating extractions using Drawing Manager, the penetrations behave oddly. Some are fine and the edge of the penetration is…
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
AECOsim Building Designer - Training April 2014
Mary Chib
There are a series of Live Distance Learn classes offered over the next month that we thought might be of interest to you or one of your colleagues. Detailed information about each class can be found on the Bentley LEARN Server from the links below…
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
RE: IFC Export. Objects lost. Aecosim Building Designer ss3
Jose Vicente
First of all, thanks for your response. I have done a test with just 3 elements. One of them works perfectly with a 3d symbol from BBES symbol, but the other one only works with a box as 3d symbol. I have made some screenshots that I have attached to…
problem 3d symbols in electrical building designer.pdf
View
Hide
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
DataGroup Definition Editor Properties
Mark Allenbrand
I have created custom properties in my DataGroup Editor. I now want to create a new custom property that concatenates the previous properties (See below for example). Is this possible? Property1 = A Property2 = B Property3 = C Property1+Property2…
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
IFC Export. Objects lost. Aecosim Building Designer ss3
Jose Vicente
Hello everyone. I am working in Aecosim Building Desing Electrical module. I have created my own Symbol Manager table from Bentley Electrical System. The problem I have is that exporting through IFC the design I have created, some of the objects…
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
AECOsim Building Designer - Training March 2014
Mary Chib
Hello, There are a series of Live Distance Learn classes offered over the next month that we thought might be of interest to you or one of your colleagues. Detailed information about each class can be found on the Bentley LEARN Server from the…
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
AECOsim Building Designer - Training February 2014
Mary Chib
Hello, Hope 2014 is off to a good and productive start. There are a series of Live Distance Learn classes offered over the next month that we thought might be of interest to you or one of your colleagues. Detailed information about each class can…
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
AECOSim not loading disciplines on startup
Duncan Gammie
Interesting issue here. When starting Aecosim, or any of its parts seperately, ABD/Structural etc, the disciplines are not loading. Any aecosim commands(ie place wall/open dataset etc) return the error 'unknown command or key in' the only way i have…
Answered
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
AECOsim Building Designer - Scheduled Training
Mary Chib
Hello, and Happy New Year! Why not get the new year off to a productive start with some training on AECOsim Building Designer ? There are a series of Live Distance Learn classes offered over the next month that we thought might be of interest to you…
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Railing with panels, is it possible?
Laurice
Is it possible, using the Railing tool, to create a railing frame with panel inserts instead of just vertical or horizontal rails? My investigations so far have suggested this cannot be done ( and no out of the box examples are provided ) as Railing…
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Editting properties of Plumbing Catalogs itens already in model
Adolfo Ribeiro
Hi, I used several itens from a manufacturer catalog in my model and now I added ERP code at the catalog itens. I need to have these ERP codes on the itens used in my model. The key-in bellow do not work for Plumbing elements: Key in: mdl load…
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Create Space / tags (Raumstempel)
Konrad Lentschig
Hi Folks, Does anybody have a ideer how this tools (Create Space) works? If anybody have an tutoriel that would help, please give an advice! Use to create my one tag (Raumstempel) Shout look like this: 01 Office/PC A= 25.67 m2 …
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Place plan collout vers place fittet section
Konrad Lentschig
Hi Folks Does anybody can explain, what the different between the both function? (pic see attached) Place plan collout vers place fittet section Why I can’t use the “ Place plan collout ” in the master model? In the core…
place plan collout vers place fittet section.pdf
View
Hide
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Endtype for Pipe - AecoSim 08.09.11.376
Adolfo Ribeiro
Hi, How can I define EndType for Pipe? I am creating a new Manufacturer Catalog and I'd like to see -:fe-2; with my pipes. Even with no catalog Pipe i can't do it. Regards, Adolfo Ribeiro
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
AECOsim Building Designer - Scheduled Training
Mary Chib
The AECOsim Building Designer LEARN services team, Dan Tanner, Paul Wagner and Mary Chib would like to announce the upcoming schedule for online distance learning classes. The online distance learning classes are offered in convenient modules to allow…
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Cobie in new ABD Beta Release (08.11.09.551)
scammels
Hi, I noticed a few great features in the new Beta release of ABD, (08.11.09.551) But does anyone else get the issue of the Cobie transformation Utility not even starting? It just displays CObBie.exe. cannot be found.. I know its a Beta…
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
US Metric Dataset
Ross Daddo
Downloaded US Metric Dataset and installed for testing with SS4 - looks good so far I like that it conforms to the US Imperial Dataset in structure eg Family&Part aligned to the new datagroup system The range of doors and windows appears similar…
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Place Plan Callout, Create gap
Johan V
Is it not possible to "Create gap" on a Plan Callout? I dont get the same options when I right click on a plan callout that I do if I right click on a "Section Callout".
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
VBA Program to Turn On/Off the Triforma 3D Setup Lock
Tom MacKnight
It is just good practice to use the floor manager to set-up your elevation working points, and so in general there is no need to be able to turn the Triforma locks on/off (ATFENV_3DSetup and ACS). But there are times when it can be a problem and it is…
ATFENV_3DSetup.mvba
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Reduce building information in section and elevation
Konrad Lentschig
Hi Folks Reduce building information in section and elevation If I create a section or elevation, there is senseless information behind a visible line (dashed line). Q: How I can organize, that the section or elevation shows only the important…
reduce information in section or elevation.pdf
View
Hide
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Re: Datagroup explorer AECOSIM
pjf
Thanks Andreas. Another questions. I have hear that PCstudio may be replace in the future ?? I've creating a paz cell, seems like rect penetrations for slab, but no the result as expected. i use Dynamic view to test it. with a top view…
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Datagroup explorer AECOSIM
pjf
Hi. We works on BA with V8I select 3. not very good. so we are waiting for aecosim... in french. I have already aecosim and begin to look at it. I have the version 225. I have read, and i note, that when we modify a parametric cell with the edit…
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Project Explorer push to spreadsheet
Shawn Foster
ABD SS4 .593 Is there a way to either push the Project Explorer structure to a spreadsheet, or maybe even link the Project Explorer structure to the Data Group Explorer to create a schedule? It would be nice to have a single push-button "create…
over 9 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Place Section Cuts with Breaklines???
Mark Allenbrand
I am using AECOsim and am trying to get a section cut to not display a solid line at the limits of the section. I would like to see a breakline or nothing at all. Any suggestions.
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
<
>