Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
AECOsim
08.11.09.829
AECOsim Building Designer
Architectural Design
Catalog
Datagroup System
Dataset and Content
Display Style/Presentation
drawing extraction
Drawing Views
Electrical Annotation and Design
en
errors
GENERAL
HVAC Design
installation
output
Platform Tools
ProjectWise integration
SELECTsupport
space
structural design
subtypes
To be archived
Windows 7 64 bit
Windows 8
workspace
TFDIR_SETTING Points to an invalid path
Satadal Dhar
Product(s): AECOsim Building Designer Version(s): V8i and CONNECT Environment: N/A Area: Configuration Subarea: N/A Problem While opening AECOsim Building Designer, you might get an error saying…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Grid model to be displayed outside of the clip reference
Gerard Torres
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: Drawing Views Subarea: N\A Problem Description We're working on a fairly large building that won't fit…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Create custom compound wall
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): V8i Environment: N\A Area: Catalog Subarea: N\A Problem Description A specific size of compound wall is needed and there isn't one in the…
over 3 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
AECOsim SS6 Installation Requirements
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): V8i SELECTseries6 Environment: N\A Area: General Subarea: Installation NOTE: This is accurate as of the date it was published. Advancements in…
over 3 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
How To Add New Level Libraries to a Workspace
Duncan Brown
Product(s): AECOsim Building Designer Version(s): V8i (08.11.09.829) Environment: N/A Area: Architectural Design Subarea: User Defined Problem After placing the BB_DVDATASETELEMENTS = 1 configuration…
over 6 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Certification of AECOsim to run on "NEST"
Gerard Torres
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: Workspace Subarea: N\A Problem Description Is AECOSim certified to run in the ARMY network…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Error loading BMECH entity system
Larry Abla
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: ProjectWise Integration Subarea: N\A Problem Description "Error loading BMECH entity system" whenever…
over 6 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Class not Registered Error on Windows 10
Larry Abla
Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: General Subarea: Errors Original Author: Larry Abla, Bentley Technical…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Object Classification descriptions in DataGroup Schedules
Larry Abla
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: DataGroup System Subarea: N\A Problem When I use the DataGroup Definition Editor to check the properties…
over 6 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Nested referneces are not exporting when publishing the i-model.
Gerard Torres
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: i-model Subarea: N\A Problem Description I am trying to create an I-model from my AECOsim model. I can…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Erstellen einer individuellen Beton Stütze oder Träger
Bettina Lautenschlaeger
Produkt(e): AECOsim Building Designer Version(en): 08.11.09.831 Umgebung: N\A Produktbereich: Structural Design Produktunterbereich: Concrete Members Hintergrund Wenn Sie auf " Betonstütze…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki (Deutsch)
Version Error in ISM import/Structural Synchronizer
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): V8i Environment: N\A Area: Import/Export Subarea: ISM Problem Description User has an ISM file from RAM but it will not import into AECOsim…
over 4 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
How to Use TFREBUILD
Larry Abla
Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: General Subarea: N\A Original Author: Larry Abla, Bentley Technical…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Unable to select some elements in the 3d model
Gerard Torres
Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: General Subarea: N\A Problem Description Unable to select some elements in the 3D model, what could be…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Placing Flex Duct Around An Obstruction
Robert DiMauro
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: HVAC Design Subarea: Ducts Problem Description How can I place a flex duct around an obstruction…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Saving a Promoted View To DWG
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: Drawing Views Subarea: N\A Saving a Promoted View To DWG When you export to dwg, does the program export…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
BBES: Cannot find BBES Database Server. Please restart BBES Database Server.
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: Electrical Annotation and Design Subarea: Building Management Problem When starting Electrical Building…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
"Could not find project or project file".
Robert DiMauro
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: Structural Design Subarea: Steel Members Problem Description When starting Truss Builder from…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
How to set reference sequence in AECOSim
Gerard Torres
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: Platform Tools Subarea: N\A Problem Description It seems that some of the references are not displaying…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Room Names/Numbers are placed very small
Larry Abla
Product(s): AECOsim Building Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When using Place Space the Room Name/Number appear very small. Method Make sure…
over 6 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
"Flood Area to create space" tool does not select complete slab area
Gerard Torres
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: Space Subarea: N\A Problem Description The "Flood Area to create space" tool doesn't take into account…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
"Flood Area to create space" won't select complete area
Gerard Torres
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: Space Subarea: N\A Problem Description The "Flood Area to create space" tool doesn't take…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Cannot place Ducts or Plumbing Features
Robert DiMauro
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: HVAC Design Subarea: N\A Problem We are having issues placing ducts, plumbing, and electrical…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
How to avoid wall from appearing behind window
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): V8i Environment: N\A Area: Drawing Views Subarea: Problem Description Wall appears behind window in the Drawing View how to prevent the wall…
over 4 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Electrical Symbol Subtypes are not following active Drawing Scale
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): 08.11.09.829 Environment: N\A Area: Electrical Annotation and Design Subarea: N\A Problem I have a DGN file that contains Electrical symbols…
over 3 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
>