Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
Automated Design
StormCAD
Automatic Design
Calculation Options
Catalog Class
CivilStorm
Conduit Catalog
default design constraints
design
design constraints
GVF-Convex
GVF-Rational
Pipe size
Reviewed2016
reviewed2017
Reviewed2018
Roughness
SewerCAD
SewerGEMS
Why are my pipes changing sizes when changing the scenario?
Chase Henrichs
I am attempting to utilize the automated design tool to size storm sewer. I was able to set up my scenario and run the automated design once using the steps outlined in the "StormCAD QuickStart" guide, section 1.2 - Automatic Design. This gave a reasonable…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Conduits being over-designed (oversized) during a design run on a system with very shallow slopes
Yashodhan Joshi
Product(s): StormCAD, CivilStorm, SewerGEMS Version(s): 08.11.03.77 and higher Area: Output and Reporting Problem Why is StormCAD over-designing the conduits during a design run on a system with very shallow slopes? (during…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Roughness not updating in conduit properties after constraint based design
Yashodhan Joshi
Product(s): SewerCAD, SewerGEMS, StormCAD, CivilStorm Version(s): 10.00.00.40 Area: Other Problem After running constraint based design with the GVF-Rational (StormCAD) or GVF-Convex (SewerCAD) solver, the roughness values…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Troubleshooting Constraint Based Design Results
Jesse Dringoli
Product(s): SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem When using constraint based Design in the GVF Rational (StormCAD) or GVF Convex (SewerCAD) solvers…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Re: SewerGEMS - Generate MH Invert Elevations
Jesse Dringoli
Jason, You can do this with SewerGEMS Sanitary's automated design feature. I would recommend reading the help documentation on this feature as well as going through quick start lesson 2. Here's a basic summary of what you'll likely be doing…
over 13 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: Pipe Size Design
Jesse Dringoli
Roman, First, you should set all conduits to be catalog conduits, choose the shape and material for each of them (you can global edit from the conduit flextable if you'd like) and then populate the Conduit Catalog with the pipe sizes that you want…
over 13 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum