Browse By Tags

  • Pump batch report prints individual force on wrong axis

    I'm currently using AutoPIPE 2023 Advanced Edition Version 23.00.00.230 and I aim to evaluate the forces and moments of the pump nozzles using the API 610 International Standard. To test this feature, I've modeled a simple pump system as follows, considering…
  • 06k. How to model piping systems not aligned with the global axis using AutoPIPE?

    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Modeling Date Logged & Current Version Sept 2022 12.08.01.010 Problem: How to model piping systems not aligned with the global axis using AutoPIPE? example…
  • 04. Is it possible to change the gravity axis from y+ to y- in AutoPIPE?

    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Load Case Date Logged & Current Version June 2020 12.03.00.17 Problem: Is it possible to change the gravity axis from y+ to y-? One user has a piping…
  • local UCS

    Hi All, Referring to my recent discussion in the forum, Karim mentioned that Bentley may consider introducing optional local UCS system (to enter coordinates with respect to the pipe run directions0. I would expect many of you may feel the same need…
  • 02. Imported axis orientation in AutoPIPE Nozzle is different than in AutoPIPE, why and can it be modified to match?

    Applies To Product(s): AutoPIPE Nozzle Version(s): V8i; Area: Import Original Author: Bentley Technical Support Group Date Logged & Current Version Aug. 2016 10.01.00.09 Problem: Imported axis orientation…
  • RE: Beam member axis

    Hello James, Please see the following AutoPIPE help section: Help > Contents> Contents Tab> Reference Information> Results Interpretation> suggest reading all these documents, but to answer your question see the following: -> Straight Pipe Forces and…
  • "TEE" - Model Input listing sub-report in AutoPIPE

    Comments, Questions, and Answers related to Model input listing: Tee sub-report: Item #1: How are local axes defined at a tee in AutoPIPE? Item #2: Why are the calculated SIF results between 2 Tees different ? See Also Component Data Listing…